ABAP Select data from SAP table PLM_S_FMEA_ACT_POWL_DETAIL into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PLM_S_FMEA_ACT_POWL_DETAIL table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PLM_S_FMEA_ACT_POWL_DETAIL. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PLM_S_FMEA_ACT_POWL_DETAIL table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PLM_S_FMEA_ACT_POWL_DETAIL TYPE STANDARD TABLE OF PLM_S_FMEA_ACT_POWL_DETAIL,
      WA_PLM_S_FMEA_ACT_POWL_DETAIL TYPE PLM_S_FMEA_ACT_POWL_DETAIL,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PLM_S_FMEA_ACT_POWL_DETAIL> TYPE PLM_S_FMEA_ACT_POWL_DETAIL.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PLM_S_FMEA_ACT_POWL_DETAIL.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PLM_S_FMEA_ACT_POWL_DETAIL
  INTO TABLE IT_PLM_S_FMEA_ACT_POWL_DETAIL.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PLM_S_FMEA_ACT_POWL_DETAIL
*  INTO TABLE @DATA(IT_PLM_S_FMEA_ACT_POWL_DETAIL2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PLM_S_FMEA_ACT_POWL_DETAIL INDEX 1 INTO DATA(WA_PLM_S_FMEA_ACT_POWL_DETAIL2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PLM_S_FMEA_ACT_POWL_DETAIL ASSIGNING <PLM_S_FMEA_ACT_POWL_DETAIL>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PLM_S_FMEA_ACT_POWL_DETAIL>-ACTION_GUID = 1.
<PLM_S_FMEA_ACT_POWL_DETAIL>-ACTION_EXTERNAL_ID = 1.
<PLM_S_FMEA_ACT_POWL_DETAIL>-ACTION_DESCRIPTION = 1.
<PLM_S_FMEA_ACT_POWL_DETAIL>-ACTION_LTEXT_IND = 1.
<PLM_S_FMEA_ACT_POWL_DETAIL>-GROUPING = 1.
ENDLOOP.

LOOP AT IT_PLM_S_FMEA_ACT_POWL_DETAIL INTO WA_PLM_S_FMEA_ACT_POWL_DETAIL.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PLM_S_FMEA_ACT_POWL_DETAIL-PROC_STATUS, sy-vline,
WA_PLM_S_FMEA_ACT_POWL_DETAIL-ACTTYP, sy-vline,
WA_PLM_S_FMEA_ACT_POWL_DETAIL-ACTTYP_TXT, sy-vline,
WA_PLM_S_FMEA_ACT_POWL_DETAIL-AUDIT_TYPE, sy-vline,
WA_PLM_S_FMEA_ACT_POWL_DETAIL-AUDIT_TYPE_TEXT, sy-vline,
WA_PLM_S_FMEA_ACT_POWL_DETAIL-COMPLETE_PERCENT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PLM_S_FMEA_ACT_POWL_DETAIL you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PLM_S_FMEA_ACT_POWL_DETAIL TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PLM_S_FMEA_ACT_POWL_DETAIL INTO WA_PLM_S_FMEA_ACT_POWL_DETAIL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PLM_S_FMEA_ACT_POWL_DETAIL_STR,
ACTION_GUID TYPE STRING,
ACTION_EXTERNAL_ID TYPE STRING,
ACTION_DESCRIPTION TYPE STRING,
ACTION_LTEXT_IND TYPE STRING,
GROUPING TYPE STRING,
PROC_STATUS TYPE STRING,
ACTTYP TYPE STRING,
ACTTYP_TXT TYPE STRING,
AUDIT_TYPE TYPE STRING,
AUDIT_TYPE_TEXT TYPE STRING,
COMPLETE_PERCENT TYPE STRING,
PLANSTARTDATE TYPE STRING,
PLANFINISHDATE TYPE STRING,
RESPONSIBLE_NAME TYPE STRING,
RESPONSIBLE_TEXT TYPE STRING,
PARENT_EXTERNAL_ID TYPE STRING,
PARENT_GUID TYPE STRING,
ASSESSM_PROFIL TYPE STRING,
PROFILE_TEXT TYPE STRING,
ASSESSMENT_REC TYPE STRING,
ASSESSM_RES TYPE STRING,
ASSESSM_RES_TEXT TYPE STRING,
SCORE_REC TYPE STRING,
ASSESSM_RES_OLD TYPE STRING,
ASSESSM_RES_OLD_TEXT TYPE STRING,
SCORE_REC_OLD TYPE STRING,
SCORE_RES_OLD TYPE STRING,
CONFIRMATION TYPE STRING,
CONFIRM_TIME TYPE STRING,
MAKAT TYPE STRING,
GRUPPE TYPE STRING,
CODE TYPE STRING,
CODE_TEXT TYPE STRING,
CODE_COMBINED TYPE STRING,
ACT_CANCEL TYPE STRING,
REFERENCE_ID TYPE STRING,
REFERENCE_TXT TYPE STRING,
START_ACTION TYPE STRING,
QMNUM TYPE STRING,
FENUM TYPE STRING,
MANUM TYPE STRING,
FMEA_GUID TYPE STRING,
FMEA_EXTERNAL_ID TYPE STRING,
MATERIAL TYPE STRING,
MATERIAL_TEXT TYPE STRING,
VENDOR TYPE STRING,
VENDOR_TEXT TYPE STRING,
CUSTOMER TYPE STRING,
CUSTOMER_TEXT TYPE STRING,
EQUI TYPE STRING,
EQUI_TEXT TYPE STRING,
FULO TYPE STRING,
FULO_TEXT TYPE STRING,
WBS TYPE STRING,
WBS_TEXT TYPE STRING,
MORE_THAN_ONE_MAT_IND TYPE STRING,
MORE_THAN_ONE_CUST_IND TYPE STRING,
MORE_THAN_ONE_VEND_IND TYPE STRING,
STATUS TYPE STRING,
STATUS_CRT TYPE STRING,
STATUS_IN_PROC TYPE STRING,
STATUS_REL TYPE STRING,
STATUS_CMPL TYPE STRING,
STATUS_LOCK TYPE STRING,
STATUS_FLAG_ARCH TYPE STRING,
STATUS_ARCH TYPE STRING,
STATUS_FLAG_APPR TYPE STRING,
STATUS_REJ TYPE STRING,
STATUS_APPR TYPE STRING,
STATUS_FLAG_DEL TYPE STRING,
STATUS_CNCL TYPE STRING,
STATUS_UNPLND TYPE STRING,
STATUS_QST_ASSGND TYPE STRING,
STATUS_DWNLD TYPE STRING,
STATUS_CONF TYPE STRING,
STATUS_REP_CRT TYPE STRING,
STATUS_SIGND TYPE STRING,
STATUS_OUST_ACTS TYPE STRING,
STATUS_ACTS_CMPLD TYPE STRING,
STATUS_CMPL_W_ACTS TYPE STRING,
STATUS_ACT_CRT TYPE STRING,
STATUS_ACT_OUT_STNDNG TYPE STRING,
STATUS_ACT_FRCD_CMPLTN TYPE STRING,
STATUS_ASSESSED TYPE STRING,
STATUS_CMPL_PART_SIGND TYPE STRING,
STATUS_CMPL_SIGND TYPE STRING,
QUALITYACTIVITYDETAILLONGTEXT TYPE STRING,
QUALITYACTIVITYDETAILPARTNER TYPE STRING,
QUALITYACTIVITYDETAILOBJECT TYPE STRING,END OF T_EKKO_STR. DATA: WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-ACTION_GUID sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-ACTION_EXTERNAL_ID sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-ACTION_DESCRIPTION sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-ACTION_LTEXT_IND sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-GROUPING sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-PROC_STATUS sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-ACTTYP sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-ACTTYP_TXT sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-AUDIT_TYPE sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-AUDIT_TYPE_TEXT sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-COMPLETE_PERCENT sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-PLANSTARTDATE sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-PLANFINISHDATE sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-RESPONSIBLE_NAME sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-RESPONSIBLE_TEXT sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-PARENT_EXTERNAL_ID sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-PARENT_GUID sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-ASSESSM_PROFIL sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-PROFILE_TEXT sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-ASSESSMENT_REC sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-ASSESSM_RES sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-ASSESSM_RES_TEXT sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-SCORE_REC sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-ASSESSM_RES_OLD sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-ASSESSM_RES_OLD_TEXT sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-SCORE_REC_OLD sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-SCORE_RES_OLD sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-CONFIRMATION sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-CONFIRM_TIME sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-MAKAT sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-GRUPPE sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-CODE sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-CODE_TEXT sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-CODE_COMBINED sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-ACT_CANCEL sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-REFERENCE_ID sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-REFERENCE_TXT sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-START_ACTION sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-QMNUM sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-FENUM sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-MANUM sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-FMEA_GUID sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-FMEA_EXTERNAL_ID sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-MATERIAL sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-MATERIAL_TEXT sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-VENDOR sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-VENDOR_TEXT sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-CUSTOMER sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-CUSTOMER_TEXT sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-EQUI sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-EQUI_TEXT sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-FULO sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-FULO_TEXT sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-WBS sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-WBS_TEXT sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-MORE_THAN_ONE_MAT_IND sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-MORE_THAN_ONE_CUST_IND sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-MORE_THAN_ONE_VEND_IND sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-STATUS sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-STATUS_CRT sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-STATUS_IN_PROC sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-STATUS_REL sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-STATUS_CMPL sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-STATUS_LOCK sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-STATUS_FLAG_ARCH sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-STATUS_ARCH sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-STATUS_FLAG_APPR sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-STATUS_REJ sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-STATUS_APPR sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-STATUS_FLAG_DEL sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-STATUS_CNCL sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-STATUS_UNPLND sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-STATUS_QST_ASSGND sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-STATUS_DWNLD sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-STATUS_CONF sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-STATUS_REP_CRT sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-STATUS_SIGND sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-STATUS_OUST_ACTS sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-STATUS_ACTS_CMPLD sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-STATUS_CMPL_W_ACTS sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-STATUS_ACT_CRT sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-STATUS_ACT_OUT_STNDNG sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-STATUS_ACT_FRCD_CMPLTN sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-STATUS_ASSESSED sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-STATUS_CMPL_PART_SIGND sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-STATUS_CMPL_SIGND sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-QUALITYACTIVITYDETAILLONGTEXT sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-QUALITYACTIVITYDETAILPARTNER sy-vline
WA_PLM_S_FMEA_ACT_POWL_DETAIL_STR-QUALITYACTIVITYDETAILOBJECT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.