ABAP Select data from SAP table PLM_PS_SEARCH_BUS2002V into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PLM_PS_SEARCH_BUS2002V table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PLM_PS_SEARCH_BUS2002V. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PLM_PS_SEARCH_BUS2002V table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PLM_PS_SEARCH_BUS2002V TYPE STANDARD TABLE OF PLM_PS_SEARCH_BUS2002V,
      WA_PLM_PS_SEARCH_BUS2002V TYPE PLM_PS_SEARCH_BUS2002V,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PLM_PS_SEARCH_BUS2002V> TYPE PLM_PS_SEARCH_BUS2002V.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PLM_PS_SEARCH_BUS2002V.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PLM_PS_SEARCH_BUS2002V
  INTO TABLE IT_PLM_PS_SEARCH_BUS2002V.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PLM_PS_SEARCH_BUS2002V
*  INTO TABLE @DATA(IT_PLM_PS_SEARCH_BUS2002V2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PLM_PS_SEARCH_BUS2002V INDEX 1 INTO DATA(WA_PLM_PS_SEARCH_BUS2002V2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PLM_PS_SEARCH_BUS2002V ASSIGNING <PLM_PS_SEARCH_BUS2002V>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PLM_PS_SEARCH_BUS2002V>-PARENT = 1.
<PLM_PS_SEARCH_BUS2002V>-OBJKEY = 1.
<PLM_PS_SEARCH_BUS2002V>-OBJTYPE = 1.
<PLM_PS_SEARCH_BUS2002V>-LOGSYS = 1.
<PLM_PS_SEARCH_BUS2002V>-TEXT = 1.
ENDLOOP.

LOOP AT IT_PLM_PS_SEARCH_BUS2002V INTO WA_PLM_PS_SEARCH_BUS2002V.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PLM_PS_SEARCH_BUS2002V-POSI, sy-vline,
WA_PLM_PS_SEARCH_BUS2002V-TIMESTAMP, sy-vline,
WA_PLM_PS_SEARCH_BUS2002V-OBJNR, sy-vline,
WA_PLM_PS_SEARCH_BUS2002V-AUFNR, sy-vline,
WA_PLM_PS_SEARCH_BUS2002V-VORNR, sy-vline,
WA_PLM_PS_SEARCH_BUS2002V-LTXA1, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PLM_PS_SEARCH_BUS2002V you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PLM_PS_SEARCH_BUS2002V TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PLM_PS_SEARCH_BUS2002V INTO WA_PLM_PS_SEARCH_BUS2002V. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field LOGSYS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PLM_PS_SEARCH_BUS2002V-LOGSYS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLM_PS_SEARCH_BUS2002V-LOGSYS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AUFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PLM_PS_SEARCH_BUS2002V-AUFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLM_PS_SEARCH_BUS2002V-AUFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field VORNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_PLM_PS_SEARCH_BUS2002V-VORNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLM_PS_SEARCH_BUS2002V-VORNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ABPSP, internal->external for field PRONR CALL FUNCTION 'CONVERSION_EXIT_ABPSP_OUTPUT' EXPORTING input = WA_PLM_PS_SEARCH_BUS2002V-PRONR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLM_PS_SEARCH_BUS2002V-PRONR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PLM_PS_SEARCH_BUS2002V_STR,
PARENT TYPE STRING,
OBJKEY TYPE STRING,
OBJTYPE TYPE STRING,
LOGSYS TYPE STRING,
TEXT TYPE STRING,
POSI TYPE STRING,
TIMESTAMP TYPE STRING,
OBJNR TYPE STRING,
AUFNR TYPE STRING,
VORNR TYPE STRING,
LTXA1 TYPE STRING,
DDLB TYPE STRING,
PRONR TYPE STRING,
STEUS TYPE STRING,END OF T_EKKO_STR. DATA: WA_PLM_PS_SEARCH_BUS2002V_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PLM_PS_SEARCH_BUS2002V_STR-PARENT sy-vline
WA_PLM_PS_SEARCH_BUS2002V_STR-OBJKEY sy-vline
WA_PLM_PS_SEARCH_BUS2002V_STR-OBJTYPE sy-vline
WA_PLM_PS_SEARCH_BUS2002V_STR-LOGSYS sy-vline
WA_PLM_PS_SEARCH_BUS2002V_STR-TEXT sy-vline
WA_PLM_PS_SEARCH_BUS2002V_STR-POSI sy-vline
WA_PLM_PS_SEARCH_BUS2002V_STR-TIMESTAMP sy-vline
WA_PLM_PS_SEARCH_BUS2002V_STR-OBJNR sy-vline
WA_PLM_PS_SEARCH_BUS2002V_STR-AUFNR sy-vline
WA_PLM_PS_SEARCH_BUS2002V_STR-VORNR sy-vline
WA_PLM_PS_SEARCH_BUS2002V_STR-LTXA1 sy-vline
WA_PLM_PS_SEARCH_BUS2002V_STR-DDLB sy-vline
WA_PLM_PS_SEARCH_BUS2002V_STR-PRONR sy-vline
WA_PLM_PS_SEARCH_BUS2002V_STR-STEUS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.