ABAP Select data from SAP table PLM_PS_DISPLAY_BUS2002 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PLM_PS_DISPLAY_BUS2002 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PLM_PS_DISPLAY_BUS2002. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PLM_PS_DISPLAY_BUS2002 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PLM_PS_DISPLAY_BUS2002 TYPE STANDARD TABLE OF PLM_PS_DISPLAY_BUS2002,
      WA_PLM_PS_DISPLAY_BUS2002 TYPE PLM_PS_DISPLAY_BUS2002,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PLM_PS_DISPLAY_BUS2002> TYPE PLM_PS_DISPLAY_BUS2002.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PLM_PS_DISPLAY_BUS2002.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PLM_PS_DISPLAY_BUS2002
  INTO TABLE IT_PLM_PS_DISPLAY_BUS2002.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PLM_PS_DISPLAY_BUS2002
*  INTO TABLE @DATA(IT_PLM_PS_DISPLAY_BUS20022).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PLM_PS_DISPLAY_BUS2002 INDEX 1 INTO DATA(WA_PLM_PS_DISPLAY_BUS20022).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PLM_PS_DISPLAY_BUS2002 ASSIGNING <PLM_PS_DISPLAY_BUS2002>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PLM_PS_DISPLAY_BUS2002>-PARENT = 1.
<PLM_PS_DISPLAY_BUS2002>-OBJKEY = 1.
<PLM_PS_DISPLAY_BUS2002>-OBJTYPE = 1.
<PLM_PS_DISPLAY_BUS2002>-LOGSYS = 1.
<PLM_PS_DISPLAY_BUS2002>-TEXT = 1.
ENDLOOP.

LOOP AT IT_PLM_PS_DISPLAY_BUS2002 INTO WA_PLM_PS_DISPLAY_BUS2002.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PLM_PS_DISPLAY_BUS2002-POSI, sy-vline,
WA_PLM_PS_DISPLAY_BUS2002-TIMESTAMP, sy-vline,
WA_PLM_PS_DISPLAY_BUS2002-OBJNR, sy-vline,
WA_PLM_PS_DISPLAY_BUS2002-AUFNR, sy-vline,
WA_PLM_PS_DISPLAY_BUS2002-KTEXT, sy-vline,
WA_PLM_PS_DISPLAY_BUS2002-DDLB, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PLM_PS_DISPLAY_BUS2002 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PLM_PS_DISPLAY_BUS2002 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PLM_PS_DISPLAY_BUS2002 INTO WA_PLM_PS_DISPLAY_BUS2002. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field LOGSYS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PLM_PS_DISPLAY_BUS2002-LOGSYS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLM_PS_DISPLAY_BUS2002-LOGSYS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AUFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PLM_PS_DISPLAY_BUS2002-AUFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLM_PS_DISPLAY_BUS2002-AUFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ABPSP, internal->external for field PSPEL CALL FUNCTION 'CONVERSION_EXIT_ABPSP_OUTPUT' EXPORTING input = WA_PLM_PS_DISPLAY_BUS2002-PSPEL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLM_PS_DISPLAY_BUS2002-PSPEL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit KONPD, internal->external for field PRONR CALL FUNCTION 'CONVERSION_EXIT_KONPD_OUTPUT' EXPORTING input = WA_PLM_PS_DISPLAY_BUS2002-PRONR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLM_PS_DISPLAY_BUS2002-PRONR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PLM_PS_DISPLAY_BUS2002_STR,
PARENT TYPE STRING,
OBJKEY TYPE STRING,
OBJTYPE TYPE STRING,
LOGSYS TYPE STRING,
TEXT TYPE STRING,
POSI TYPE STRING,
TIMESTAMP TYPE STRING,
OBJNR TYPE STRING,
AUFNR TYPE STRING,
KTEXT TYPE STRING,
DDLB TYPE STRING,
ERNAM TYPE STRING,
DISPO TYPE STRING,
PSPEL TYPE STRING,
PRONR TYPE STRING,
GSTRP TYPE STRING,
GLTRP TYPE STRING,END OF T_EKKO_STR. DATA: WA_PLM_PS_DISPLAY_BUS2002_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PLM_PS_DISPLAY_BUS2002_STR-PARENT sy-vline
WA_PLM_PS_DISPLAY_BUS2002_STR-OBJKEY sy-vline
WA_PLM_PS_DISPLAY_BUS2002_STR-OBJTYPE sy-vline
WA_PLM_PS_DISPLAY_BUS2002_STR-LOGSYS sy-vline
WA_PLM_PS_DISPLAY_BUS2002_STR-TEXT sy-vline
WA_PLM_PS_DISPLAY_BUS2002_STR-POSI sy-vline
WA_PLM_PS_DISPLAY_BUS2002_STR-TIMESTAMP sy-vline
WA_PLM_PS_DISPLAY_BUS2002_STR-OBJNR sy-vline
WA_PLM_PS_DISPLAY_BUS2002_STR-AUFNR sy-vline
WA_PLM_PS_DISPLAY_BUS2002_STR-KTEXT sy-vline
WA_PLM_PS_DISPLAY_BUS2002_STR-DDLB sy-vline
WA_PLM_PS_DISPLAY_BUS2002_STR-ERNAM sy-vline
WA_PLM_PS_DISPLAY_BUS2002_STR-DISPO sy-vline
WA_PLM_PS_DISPLAY_BUS2002_STR-PSPEL sy-vline
WA_PLM_PS_DISPLAY_BUS2002_STR-PRONR sy-vline
WA_PLM_PS_DISPLAY_BUS2002_STR-GSTRP sy-vline
WA_PLM_PS_DISPLAY_BUS2002_STR-GLTRP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.