ABAP Select data from SAP table PIR_V_ALL_ATT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PIR_V_ALL_ATT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PIR_V_ALL_ATT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PIR_V_ALL_ATT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PIR_V_ALL_ATT TYPE STANDARD TABLE OF PIR_V_ALL_ATT,
      WA_PIR_V_ALL_ATT TYPE PIR_V_ALL_ATT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PIR_V_ALL_ATT> TYPE PIR_V_ALL_ATT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PIR_V_ALL_ATT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PIR_V_ALL_ATT
  INTO TABLE IT_PIR_V_ALL_ATT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PIR_V_ALL_ATT
*  INTO TABLE @DATA(IT_PIR_V_ALL_ATT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PIR_V_ALL_ATT INDEX 1 INTO DATA(WA_PIR_V_ALL_ATT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PIR_V_ALL_ATT ASSIGNING <PIR_V_ALL_ATT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PIR_V_ALL_ATT>-MANDT = 1.
<PIR_V_ALL_ATT>-MATNR = 1.
<PIR_V_ALL_ATT>-WERKS = 1.
<PIR_V_ALL_ATT>-BERID = 1.
<PIR_V_ALL_ATT>-BEDAE = 1.
ENDLOOP.

LOOP AT IT_PIR_V_ALL_ATT INTO WA_PIR_V_ALL_ATT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PIR_V_ALL_ATT-VERSB, sy-vline,
WA_PIR_V_ALL_ATT-PDATU, sy-vline,
WA_PIR_V_ALL_ATT-PBDNR, sy-vline,
WA_PIR_V_ALL_ATT-PER_SDAT, sy-vline,
WA_PIR_V_ALL_ATT-PER_EDAT, sy-vline,
WA_PIR_V_ALL_ATT-LOEVR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PIR_V_ALL_ATT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PIR_V_ALL_ATT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PIR_V_ALL_ATT INTO WA_PIR_V_ALL_ATT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_PIR_V_ALL_ATT-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PIR_V_ALL_ATT-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PIR_V_ALL_ATT-MEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PIR_V_ALL_ATT-MEINS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PIR_V_ALL_ATT_STR,
MANDT TYPE STRING,
MATNR TYPE STRING,
WERKS TYPE STRING,
BERID TYPE STRING,
BEDAE TYPE STRING,
VERSB TYPE STRING,
PDATU TYPE STRING,
PBDNR TYPE STRING,
PER_SDAT TYPE STRING,
PER_EDAT TYPE STRING,
LOEVR TYPE STRING,
MEINS TYPE STRING,
DRAFT_QTY TYPE STRING,
PLAN_QTY TYPE STRING,
WITHDR_QTY TYPE STRING,
OPEN_QTY TYPE STRING,
ACC_PAST TYPE STRING,
RELEASED TYPE STRING,
BDZEI TYPE STRING,
AENAM TYPE STRING,
VERVS TYPE STRING,
PERKZ_ITEM TYPE STRING,
LAEDA TYPE STRING,END OF T_EKKO_STR. DATA: WA_PIR_V_ALL_ATT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PIR_V_ALL_ATT_STR-MANDT sy-vline
WA_PIR_V_ALL_ATT_STR-MATNR sy-vline
WA_PIR_V_ALL_ATT_STR-WERKS sy-vline
WA_PIR_V_ALL_ATT_STR-BERID sy-vline
WA_PIR_V_ALL_ATT_STR-BEDAE sy-vline
WA_PIR_V_ALL_ATT_STR-VERSB sy-vline
WA_PIR_V_ALL_ATT_STR-PDATU sy-vline
WA_PIR_V_ALL_ATT_STR-PBDNR sy-vline
WA_PIR_V_ALL_ATT_STR-PER_SDAT sy-vline
WA_PIR_V_ALL_ATT_STR-PER_EDAT sy-vline
WA_PIR_V_ALL_ATT_STR-LOEVR sy-vline
WA_PIR_V_ALL_ATT_STR-MEINS sy-vline
WA_PIR_V_ALL_ATT_STR-DRAFT_QTY sy-vline
WA_PIR_V_ALL_ATT_STR-PLAN_QTY sy-vline
WA_PIR_V_ALL_ATT_STR-WITHDR_QTY sy-vline
WA_PIR_V_ALL_ATT_STR-OPEN_QTY sy-vline
WA_PIR_V_ALL_ATT_STR-ACC_PAST sy-vline
WA_PIR_V_ALL_ATT_STR-RELEASED sy-vline
WA_PIR_V_ALL_ATT_STR-BDZEI sy-vline
WA_PIR_V_ALL_ATT_STR-AENAM sy-vline
WA_PIR_V_ALL_ATT_STR-VERVS sy-vline
WA_PIR_V_ALL_ATT_STR-PERKZ_ITEM sy-vline
WA_PIR_V_ALL_ATT_STR-LAEDA sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.