ABAP Select data from SAP table PIQRULEACADIX into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PIQRULEACADIX table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PIQRULEACADIX. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PIQRULEACADIX table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PIQRULEACADIX TYPE STANDARD TABLE OF PIQRULEACADIX,
      WA_PIQRULEACADIX TYPE PIQRULEACADIX,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PIQRULEACADIX> TYPE PIQRULEACADIX.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PIQRULEACADIX.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PIQRULEACADIX
  INTO TABLE IT_PIQRULEACADIX.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PIQRULEACADIX
*  INTO TABLE @DATA(IT_PIQRULEACADIX2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PIQRULEACADIX INDEX 1 INTO DATA(WA_PIQRULEACADIX2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PIQRULEACADIX ASSIGNING <PIQRULEACADIX>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PIQRULEACADIX>-SINDX_1 = 1.
<PIQRULEACADIX>-SINDX_2 = 1.
<PIQRULEACADIX>-SINDX_3 = 1.
<PIQRULEACADIX>-SINDX_4 = 1.
<PIQRULEACADIX>-SINDX_5 = 1.
ENDLOOP.

LOOP AT IT_PIQRULEACADIX INTO WA_PIQRULEACADIX.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PIQRULEACADIX-SINDX_6, sy-vline,
WA_PIQRULEACADIX-SINDX_7, sy-vline,
WA_PIQRULEACADIX-SINDX_8, sy-vline,
WA_PIQRULEACADIX-SINDX_9, sy-vline,
WA_PIQRULEACADIX-SINDX_10, sy-vline,
WA_PIQRULEACADIX-SINDX_11, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PIQRULEACADIX you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PIQRULEACADIX TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PIQRULEACADIX INTO WA_PIQRULEACADIX. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PIQRULEACADIX_STR,
SINDX_1 TYPE STRING,
SINDX_2 TYPE STRING,
SINDX_3 TYPE STRING,
SINDX_4 TYPE STRING,
SINDX_5 TYPE STRING,
SINDX_6 TYPE STRING,
SINDX_7 TYPE STRING,
SINDX_8 TYPE STRING,
SINDX_9 TYPE STRING,
SINDX_10 TYPE STRING,
SINDX_11 TYPE STRING,
SINDX_12 TYPE STRING,
SINDX_13 TYPE STRING,
SINDX_14 TYPE STRING,
SINDX_15 TYPE STRING,
SINDX_16 TYPE STRING,
SINDX_17 TYPE STRING,
SINDX_18 TYPE STRING,
SINDX_19 TYPE STRING,
SINDX_20 TYPE STRING,
SFLAG_1 TYPE STRING,
SFLAG_2 TYPE STRING,
SFLAG_3 TYPE STRING,
SFLAG_4 TYPE STRING,
SFLAG_5 TYPE STRING,END OF T_EKKO_STR. DATA: WA_PIQRULEACADIX_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PIQRULEACADIX_STR-SINDX_1 sy-vline
WA_PIQRULEACADIX_STR-SINDX_2 sy-vline
WA_PIQRULEACADIX_STR-SINDX_3 sy-vline
WA_PIQRULEACADIX_STR-SINDX_4 sy-vline
WA_PIQRULEACADIX_STR-SINDX_5 sy-vline
WA_PIQRULEACADIX_STR-SINDX_6 sy-vline
WA_PIQRULEACADIX_STR-SINDX_7 sy-vline
WA_PIQRULEACADIX_STR-SINDX_8 sy-vline
WA_PIQRULEACADIX_STR-SINDX_9 sy-vline
WA_PIQRULEACADIX_STR-SINDX_10 sy-vline
WA_PIQRULEACADIX_STR-SINDX_11 sy-vline
WA_PIQRULEACADIX_STR-SINDX_12 sy-vline
WA_PIQRULEACADIX_STR-SINDX_13 sy-vline
WA_PIQRULEACADIX_STR-SINDX_14 sy-vline
WA_PIQRULEACADIX_STR-SINDX_15 sy-vline
WA_PIQRULEACADIX_STR-SINDX_16 sy-vline
WA_PIQRULEACADIX_STR-SINDX_17 sy-vline
WA_PIQRULEACADIX_STR-SINDX_18 sy-vline
WA_PIQRULEACADIX_STR-SINDX_19 sy-vline
WA_PIQRULEACADIX_STR-SINDX_20 sy-vline
WA_PIQRULEACADIX_STR-SFLAG_1 sy-vline
WA_PIQRULEACADIX_STR-SFLAG_2 sy-vline
WA_PIQRULEACADIX_STR-SFLAG_3 sy-vline
WA_PIQRULEACADIX_STR-SFLAG_4 sy-vline
WA_PIQRULEACADIX_STR-SFLAG_5 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.