ABAP Select data from SAP table PIQPP_EV_GRADING into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PIQPP_EV_GRADING table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PIQPP_EV_GRADING. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PIQPP_EV_GRADING table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PIQPP_EV_GRADING TYPE STANDARD TABLE OF PIQPP_EV_GRADING,
      WA_PIQPP_EV_GRADING TYPE PIQPP_EV_GRADING,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PIQPP_EV_GRADING> TYPE PIQPP_EV_GRADING.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PIQPP_EV_GRADING.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PIQPP_EV_GRADING
  INTO TABLE IT_PIQPP_EV_GRADING.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PIQPP_EV_GRADING
*  INTO TABLE @DATA(IT_PIQPP_EV_GRADING2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PIQPP_EV_GRADING INDEX 1 INTO DATA(WA_PIQPP_EV_GRADING2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PIQPP_EV_GRADING ASSIGNING <PIQPP_EV_GRADING>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PIQPP_EV_GRADING>-AGRTYPE = 1.
<PIQPP_EV_GRADING>-AGRSTAT = 1.
<PIQPP_EV_GRADING>-GRADESYMBOL = 1.
<PIQPP_EV_GRADING>-GRADE = 1.
<PIQPP_EV_GRADING>-GRADESCALE = 1.
ENDLOOP.

LOOP AT IT_PIQPP_EV_GRADING INTO WA_PIQPP_EV_GRADING.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PIQPP_EV_GRADING-AGRNOTRATED, sy-vline,
WA_PIQPP_EV_GRADING-AGRDATE, sy-vline,
WA_PIQPP_EV_GRADING-AGRCOMPLETED, sy-vline,
WA_PIQPP_EV_GRADING-CPATTEMP, sy-vline,
WA_PIQPP_EV_GRADING-CPEARNED, sy-vline,
WA_PIQPP_EV_GRADING-CPGRADED, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PIQPP_EV_GRADING you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PIQPP_EV_GRADING TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PIQPP_EV_GRADING INTO WA_PIQPP_EV_GRADING. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field CPUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PIQPP_EV_GRADING-CPUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PIQPP_EV_GRADING-CPUNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PIQPP_EV_GRADING_STR,
AGRTYPE TYPE STRING,
AGRSTAT TYPE STRING,
GRADESYMBOL TYPE STRING,
GRADE TYPE STRING,
GRADESCALE TYPE STRING,
AGRNOTRATED TYPE STRING,
AGRDATE TYPE STRING,
AGRCOMPLETED TYPE STRING,
CPATTEMP TYPE STRING,
CPEARNED TYPE STRING,
CPGRADED TYPE STRING,
CPUNIT TYPE STRING,
AGRREMARK TYPE STRING,
AGRBEGDA TYPE STRING,
AGRENDDA TYPE STRING,
ARCH_STATUS TYPE STRING,
NOTEID TYPE STRING,
GRADECHANGED TYPE STRING,
PUBLICATIONDATE TYPE STRING,
BKG_STATUS_CHANGED TYPE STRING,
PREV_BKG_STATUS TYPE STRING,
PROGRAMTYPESBEF TYPE STRING,
PROGRAMSBEF TYPE STRING,END OF T_EKKO_STR. DATA: WA_PIQPP_EV_GRADING_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PIQPP_EV_GRADING_STR-AGRTYPE sy-vline
WA_PIQPP_EV_GRADING_STR-AGRSTAT sy-vline
WA_PIQPP_EV_GRADING_STR-GRADESYMBOL sy-vline
WA_PIQPP_EV_GRADING_STR-GRADE sy-vline
WA_PIQPP_EV_GRADING_STR-GRADESCALE sy-vline
WA_PIQPP_EV_GRADING_STR-AGRNOTRATED sy-vline
WA_PIQPP_EV_GRADING_STR-AGRDATE sy-vline
WA_PIQPP_EV_GRADING_STR-AGRCOMPLETED sy-vline
WA_PIQPP_EV_GRADING_STR-CPATTEMP sy-vline
WA_PIQPP_EV_GRADING_STR-CPEARNED sy-vline
WA_PIQPP_EV_GRADING_STR-CPGRADED sy-vline
WA_PIQPP_EV_GRADING_STR-CPUNIT sy-vline
WA_PIQPP_EV_GRADING_STR-AGRREMARK sy-vline
WA_PIQPP_EV_GRADING_STR-AGRBEGDA sy-vline
WA_PIQPP_EV_GRADING_STR-AGRENDDA sy-vline
WA_PIQPP_EV_GRADING_STR-ARCH_STATUS sy-vline
WA_PIQPP_EV_GRADING_STR-NOTEID sy-vline
WA_PIQPP_EV_GRADING_STR-GRADECHANGED sy-vline
WA_PIQPP_EV_GRADING_STR-PUBLICATIONDATE sy-vline
WA_PIQPP_EV_GRADING_STR-BKG_STATUS_CHANGED sy-vline
WA_PIQPP_EV_GRADING_STR-PREV_BKG_STATUS sy-vline
WA_PIQPP_EV_GRADING_STR-PROGRAMTYPESBEF sy-vline
WA_PIQPP_EV_GRADING_STR-PROGRAMSBEF sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.