ABAP Select data from SAP table PIQCORR_STRU_CMS0_DEG into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PIQCORR_STRU_CMS0_DEG table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PIQCORR_STRU_CMS0_DEG. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PIQCORR_STRU_CMS0_DEG table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PIQCORR_STRU_CMS0_DEG TYPE STANDARD TABLE OF PIQCORR_STRU_CMS0_DEG,
      WA_PIQCORR_STRU_CMS0_DEG TYPE PIQCORR_STRU_CMS0_DEG,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PIQCORR_STRU_CMS0_DEG> TYPE PIQCORR_STRU_CMS0_DEG.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PIQCORR_STRU_CMS0_DEG.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PIQCORR_STRU_CMS0_DEG
  INTO TABLE IT_PIQCORR_STRU_CMS0_DEG.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PIQCORR_STRU_CMS0_DEG
*  INTO TABLE @DATA(IT_PIQCORR_STRU_CMS0_DEG2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PIQCORR_STRU_CMS0_DEG INDEX 1 INTO DATA(WA_PIQCORR_STRU_CMS0_DEG2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PIQCORR_STRU_CMS0_DEG ASSIGNING <PIQCORR_STRU_CMS0_DEG>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PIQCORR_STRU_CMS0_DEG>-WA_DEG = 1.
<PIQCORR_STRU_CMS0_DEG>-DEGREENR = 1.
<PIQCORR_STRU_CMS0_DEG>-DEGREEID = 1.
<PIQCORR_STRU_CMS0_DEG>-PROGRAMID = 1.
<PIQCORR_STRU_CMS0_DEG>-DEGERNFLAG = 1.
ENDLOOP.

LOOP AT IT_PIQCORR_STRU_CMS0_DEG INTO WA_PIQCORR_STRU_CMS0_DEG.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PIQCORR_STRU_CMS0_DEG-DEGDATE, sy-vline,
WA_PIQCORR_STRU_CMS0_DEG-DEGEXTGRADE, sy-vline,
WA_PIQCORR_STRU_CMS0_DEG-DEGEXTSCALEID, sy-vline,
WA_PIQCORR_STRU_CMS0_DEG-DEGHONORS, sy-vline,
WA_PIQCORR_STRU_CMS0_DEG-WA_DEGT, sy-vline,
WA_PIQCORR_STRU_CMS0_DEG-DEGREESHORT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PIQCORR_STRU_CMS0_DEG you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PIQCORR_STRU_CMS0_DEG TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PIQCORR_STRU_CMS0_DEG INTO WA_PIQCORR_STRU_CMS0_DEG. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PIQCORR_STRU_CMS0_DEG_STR,
WA_DEG TYPE STRING,
DEGREENR TYPE STRING,
DEGREEID TYPE STRING,
PROGRAMID TYPE STRING,
DEGERNFLAG TYPE STRING,
DEGDATE TYPE STRING,
DEGEXTGRADE TYPE STRING,
DEGEXTSCALEID TYPE STRING,
DEGHONORS TYPE STRING,
WA_DEGT TYPE STRING,
DEGREESHORT TYPE STRING,
DEGREESTEXT TYPE STRING,
PROGRAMSHORT TYPE STRING,
PROGRAMSTEXT TYPE STRING,
DEGEXTGRADETEXT TYPE STRING,
DEGEXTGRADESCALET TYPE STRING,END OF T_EKKO_STR. DATA: WA_PIQCORR_STRU_CMS0_DEG_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PIQCORR_STRU_CMS0_DEG_STR-WA_DEG sy-vline
WA_PIQCORR_STRU_CMS0_DEG_STR-DEGREENR sy-vline
WA_PIQCORR_STRU_CMS0_DEG_STR-DEGREEID sy-vline
WA_PIQCORR_STRU_CMS0_DEG_STR-PROGRAMID sy-vline
WA_PIQCORR_STRU_CMS0_DEG_STR-DEGERNFLAG sy-vline
WA_PIQCORR_STRU_CMS0_DEG_STR-DEGDATE sy-vline
WA_PIQCORR_STRU_CMS0_DEG_STR-DEGEXTGRADE sy-vline
WA_PIQCORR_STRU_CMS0_DEG_STR-DEGEXTSCALEID sy-vline
WA_PIQCORR_STRU_CMS0_DEG_STR-DEGHONORS sy-vline
WA_PIQCORR_STRU_CMS0_DEG_STR-WA_DEGT sy-vline
WA_PIQCORR_STRU_CMS0_DEG_STR-DEGREESHORT sy-vline
WA_PIQCORR_STRU_CMS0_DEG_STR-DEGREESTEXT sy-vline
WA_PIQCORR_STRU_CMS0_DEG_STR-PROGRAMSHORT sy-vline
WA_PIQCORR_STRU_CMS0_DEG_STR-PROGRAMSTEXT sy-vline
WA_PIQCORR_STRU_CMS0_DEG_STR-DEGEXTGRADETEXT sy-vline
WA_PIQCORR_STRU_CMS0_DEG_STR-DEGEXTGRADESCALET sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.