ABAP Select data from SAP table PIQ_GET_SM_SE_PAD506 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PIQ_GET_SM_SE_PAD506 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PIQ_GET_SM_SE_PAD506. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PIQ_GET_SM_SE_PAD506 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PIQ_GET_SM_SE_PAD506 TYPE STANDARD TABLE OF PIQ_GET_SM_SE_PAD506,
      WA_PIQ_GET_SM_SE_PAD506 TYPE PIQ_GET_SM_SE_PAD506,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PIQ_GET_SM_SE_PAD506> TYPE PIQ_GET_SM_SE_PAD506.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PIQ_GET_SM_SE_PAD506.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PIQ_GET_SM_SE_PAD506
  INTO TABLE IT_PIQ_GET_SM_SE_PAD506.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PIQ_GET_SM_SE_PAD506
*  INTO TABLE @DATA(IT_PIQ_GET_SM_SE_PAD5062).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PIQ_GET_SM_SE_PAD506 INDEX 1 INTO DATA(WA_PIQ_GET_SM_SE_PAD5062).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PIQ_GET_SM_SE_PAD506 ASSIGNING <PIQ_GET_SM_SE_PAD506>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PIQ_GET_SM_SE_PAD506>-PLVAR = 1.
<PIQ_GET_SM_SE_PAD506>-SM_OBJID = 1.
<PIQ_GET_SM_SE_PAD506>-BEGDA = 1.
<PIQ_GET_SM_SE_PAD506>-ENDDA = 1.
<PIQ_GET_SM_SE_PAD506>-PRIOX = 1.
ENDLOOP.

LOOP AT IT_PIQ_GET_SM_SE_PAD506 INTO WA_PIQ_GET_SM_SE_PAD506.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PIQ_GET_SM_SE_PAD506-SMSTATUS, sy-vline,
WA_PIQ_GET_SM_SE_PAD506-STORREASON, sy-vline,
WA_PIQ_GET_SM_SE_PAD506-STORDATE, sy-vline,
WA_PIQ_GET_SM_SE_PAD506-CPATTEMP, sy-vline,
WA_PIQ_GET_SM_SE_PAD506-CPGAINED, sy-vline,
WA_PIQ_GET_SM_SE_PAD506-CPUNIT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PIQ_GET_SM_SE_PAD506 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PIQ_GET_SM_SE_PAD506 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PIQ_GET_SM_SE_PAD506 INTO WA_PIQ_GET_SM_SE_PAD506. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field CPUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PIQ_GET_SM_SE_PAD506-CPUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PIQ_GET_SM_SE_PAD506-CPUNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PIQ_GET_SM_SE_PAD506_STR,
PLVAR TYPE STRING,
SM_OBJID TYPE STRING,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
PRIOX TYPE STRING,
SMSTATUS TYPE STRING,
STORREASON TYPE STRING,
STORDATE TYPE STRING,
CPATTEMP TYPE STRING,
CPGAINED TYPE STRING,
CPUNIT TYPE STRING,
NORM_VAL TYPE STRING,
BOOKDATE TYPE STRING,
BOOKTIME TYPE STRING,
SMRATING TYPE STRING,
CHARGEFREE TYPE STRING,
TRANSFERFLAG TYPE STRING,
PACKNUMBER TYPE STRING,
VARID TYPE STRING,
PERID TYPE STRING,
PERYR TYPE STRING,
ALT_SCALEID TYPE STRING,
ID TYPE STRING,
BOOKREASON TYPE STRING,
ANNULMENT TYPE STRING,
LOCKFLAG TYPE STRING,
COBOK TYPE STRING,
BOOKING_SUBGROUP_ID TYPE STRING,
ATTNO_TW TYPE STRING,END OF T_EKKO_STR. DATA: WA_PIQ_GET_SM_SE_PAD506_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PIQ_GET_SM_SE_PAD506_STR-PLVAR sy-vline
WA_PIQ_GET_SM_SE_PAD506_STR-SM_OBJID sy-vline
WA_PIQ_GET_SM_SE_PAD506_STR-BEGDA sy-vline
WA_PIQ_GET_SM_SE_PAD506_STR-ENDDA sy-vline
WA_PIQ_GET_SM_SE_PAD506_STR-PRIOX sy-vline
WA_PIQ_GET_SM_SE_PAD506_STR-SMSTATUS sy-vline
WA_PIQ_GET_SM_SE_PAD506_STR-STORREASON sy-vline
WA_PIQ_GET_SM_SE_PAD506_STR-STORDATE sy-vline
WA_PIQ_GET_SM_SE_PAD506_STR-CPATTEMP sy-vline
WA_PIQ_GET_SM_SE_PAD506_STR-CPGAINED sy-vline
WA_PIQ_GET_SM_SE_PAD506_STR-CPUNIT sy-vline
WA_PIQ_GET_SM_SE_PAD506_STR-NORM_VAL sy-vline
WA_PIQ_GET_SM_SE_PAD506_STR-BOOKDATE sy-vline
WA_PIQ_GET_SM_SE_PAD506_STR-BOOKTIME sy-vline
WA_PIQ_GET_SM_SE_PAD506_STR-SMRATING sy-vline
WA_PIQ_GET_SM_SE_PAD506_STR-CHARGEFREE sy-vline
WA_PIQ_GET_SM_SE_PAD506_STR-TRANSFERFLAG sy-vline
WA_PIQ_GET_SM_SE_PAD506_STR-PACKNUMBER sy-vline
WA_PIQ_GET_SM_SE_PAD506_STR-VARID sy-vline
WA_PIQ_GET_SM_SE_PAD506_STR-PERID sy-vline
WA_PIQ_GET_SM_SE_PAD506_STR-PERYR sy-vline
WA_PIQ_GET_SM_SE_PAD506_STR-ALT_SCALEID sy-vline
WA_PIQ_GET_SM_SE_PAD506_STR-ID sy-vline
WA_PIQ_GET_SM_SE_PAD506_STR-BOOKREASON sy-vline
WA_PIQ_GET_SM_SE_PAD506_STR-ANNULMENT sy-vline
WA_PIQ_GET_SM_SE_PAD506_STR-LOCKFLAG sy-vline
WA_PIQ_GET_SM_SE_PAD506_STR-COBOK sy-vline
WA_PIQ_GET_SM_SE_PAD506_STR-BOOKING_SUBGROUP_ID sy-vline
WA_PIQ_GET_SM_SE_PAD506_STR-ATTNO_TW sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.