ABAP Select data from SAP table PINSPRSLTRECG into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PINSPRSLTRECG table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PINSPRSLTRECG. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PINSPRSLTRECG table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PINSPRSLTRECG TYPE STANDARD TABLE OF PINSPRSLTRECG,
      WA_PINSPRSLTRECG TYPE PINSPRSLTRECG,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PINSPRSLTRECG> TYPE PINSPRSLTRECG.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PINSPRSLTRECG.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PINSPRSLTRECG
  INTO TABLE IT_PINSPRSLTRECG.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PINSPRSLTRECG
*  INTO TABLE @DATA(IT_PINSPRSLTRECG2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PINSPRSLTRECG INDEX 1 INTO DATA(WA_PINSPRSLTRECG2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PINSPRSLTRECG ASSIGNING <PINSPRSLTRECG>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PINSPRSLTRECG>-MANDT = 1.
<PINSPRSLTRECG>-INSPECTIONLOT = 1.
<PINSPRSLTRECG>-INSPLOTRSLTRECGSTATUSTEXT = 1.
<PINSPRSLTRECG>-INSPLOTRSLTRECGSTATUS = 1.
<PINSPRSLTRECG>-PLANT = 1.
ENDLOOP.

LOOP AT IT_PINSPRSLTRECG INTO WA_PINSPRSLTRECG.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PINSPRSLTRECG-INSPECTIONLOTORIGIN, sy-vline,
WA_PINSPRSLTRECG-INSPECTIONLOTTYPE, sy-vline,
WA_PINSPRSLTRECG-MATERIAL, sy-vline,
WA_PINSPRSLTRECG-INSPECTIONLOTSTORAGELOCATION, sy-vline,
WA_PINSPRSLTRECG-BATCHSTORAGELOCATION, sy-vline,
WA_PINSPRSLTRECG-MATLQUALITYAUTHORIZATIONGROUP, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PINSPRSLTRECG you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PINSPRSLTRECG TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PINSPRSLTRECG INTO WA_PINSPRSLTRECG. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field INSPECTIONLOT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PINSPRSLTRECG-INSPECTIONLOT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PINSPRSLTRECG-INSPECTIONLOT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATERIAL CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_PINSPRSLTRECG-MATERIAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PINSPRSLTRECG-MATERIAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SUPPLIER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PINSPRSLTRECG-SUPPLIER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PINSPRSLTRECG-SUPPLIER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field MANUFACTURER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PINSPRSLTRECG-MANUFACTURER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PINSPRSLTRECG-MANUFACTURER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MANUFACTURERPARTNMBR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_PINSPRSLTRECG-MANUFACTURERPARTNMBR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PINSPRSLTRECG-MANUFACTURERPARTNMBR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field CUSTOMER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PINSPRSLTRECG-CUSTOMER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PINSPRSLTRECG-CUSTOMER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SOLDTOPARTY CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PINSPRSLTRECG-SOLDTOPARTY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PINSPRSLTRECG-SOLDTOPARTY.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PINSPRSLTRECG_STR,
MANDT TYPE STRING,
INSPECTIONLOT TYPE STRING,
INSPLOTRSLTRECGSTATUSTEXT TYPE STRING,
INSPLOTRSLTRECGSTATUS TYPE STRING,
PLANT TYPE STRING,
INSPECTIONLOTORIGIN TYPE STRING,
INSPECTIONLOTTYPE TYPE STRING,
MATERIAL TYPE STRING,
INSPECTIONLOTSTORAGELOCATION TYPE STRING,
BATCHSTORAGELOCATION TYPE STRING,
MATLQUALITYAUTHORIZATIONGROUP TYPE STRING,
ISBUSINESSPURPOSECOMPLETED TYPE STRING,
SUPPLIER TYPE STRING,
MANUFACTURER TYPE STRING,
MANUFACTURERPARTNMBR TYPE STRING,
PURCHASINGORGANIZATION TYPE STRING,
INSPECTIONLOTHASQUANTITY TYPE STRING,
CUSTOMER TYPE STRING,
SOLDTOPARTY TYPE STRING,
SALESORGANIZATION TYPE STRING,
INSPECTIONLOTHASUSAGEDECISION TYPE STRING,END OF T_EKKO_STR. DATA: WA_PINSPRSLTRECG_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PINSPRSLTRECG_STR-MANDT sy-vline
WA_PINSPRSLTRECG_STR-INSPECTIONLOT sy-vline
WA_PINSPRSLTRECG_STR-INSPLOTRSLTRECGSTATUSTEXT sy-vline
WA_PINSPRSLTRECG_STR-INSPLOTRSLTRECGSTATUS sy-vline
WA_PINSPRSLTRECG_STR-PLANT sy-vline
WA_PINSPRSLTRECG_STR-INSPECTIONLOTORIGIN sy-vline
WA_PINSPRSLTRECG_STR-INSPECTIONLOTTYPE sy-vline
WA_PINSPRSLTRECG_STR-MATERIAL sy-vline
WA_PINSPRSLTRECG_STR-INSPECTIONLOTSTORAGELOCATION sy-vline
WA_PINSPRSLTRECG_STR-BATCHSTORAGELOCATION sy-vline
WA_PINSPRSLTRECG_STR-MATLQUALITYAUTHORIZATIONGROUP sy-vline
WA_PINSPRSLTRECG_STR-ISBUSINESSPURPOSECOMPLETED sy-vline
WA_PINSPRSLTRECG_STR-SUPPLIER sy-vline
WA_PINSPRSLTRECG_STR-MANUFACTURER sy-vline
WA_PINSPRSLTRECG_STR-MANUFACTURERPARTNMBR sy-vline
WA_PINSPRSLTRECG_STR-PURCHASINGORGANIZATION sy-vline
WA_PINSPRSLTRECG_STR-INSPECTIONLOTHASQUANTITY sy-vline
WA_PINSPRSLTRECG_STR-CUSTOMER sy-vline
WA_PINSPRSLTRECG_STR-SOLDTOPARTY sy-vline
WA_PINSPRSLTRECG_STR-SALESORGANIZATION sy-vline
WA_PINSPRSLTRECG_STR-INSPECTIONLOTHASUSAGEDECISION sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.