ABAP Select data from SAP table PINPEV2 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PINPEV2 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PINPEV2. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PINPEV2 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PINPEV2 TYPE STANDARD TABLE OF PINPEV2,
      WA_PINPEV2 TYPE PINPEV2,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PINPEV2> TYPE PINPEV2.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PINPEV2.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PINPEV2
  INTO TABLE IT_PINPEV2.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PINPEV2
*  INTO TABLE @DATA(IT_PINPEV22).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PINPEV2 INDEX 1 INTO DATA(WA_PINPEV22).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PINPEV2 ASSIGNING <PINPEV2>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PINPEV2>-MANDT = 1.
<PINPEV2>-POGUI = 1.
<PINPEV2>-STPID = 1.
<PINPEV2>-STDES = 1.
<PINPEV2>-ATRID = 1.
ENDLOOP.

LOOP AT IT_PINPEV2 INTO WA_PINPEV2.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PINPEV2-ATDES, sy-vline,
WA_PINPEV2-ATSEQ, sy-vline,
WA_PINPEV2-VLSEQ, sy-vline,
WA_PINPEV2-ENDDA, sy-vline,
WA_PINPEV2-BEGDA, sy-vline,
WA_PINPEV2-SIGN, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PINPEV2 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PINPEV2 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PINPEV2 INTO WA_PINPEV2. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PINPEV2-UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PINPEV2-UNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PINPEV2_STR,
MANDT TYPE STRING,
POGUI TYPE STRING,
STPID TYPE STRING,
STDES TYPE STRING,
ATRID TYPE STRING,
ATDES TYPE STRING,
ATSEQ TYPE STRING,
VLSEQ TYPE STRING,
ENDDA TYPE STRING,
BEGDA TYPE STRING,
SIGN TYPE STRING,
SGDES TYPE STRING,
OPTTY TYPE STRING,
OPDES TYPE STRING,
LOWVA TYPE STRING,
HIHVA TYPE STRING,
UNIT TYPE STRING,
BVAL TYPE STRING,
ANDOR TYPE STRING,
XINDI TYPE STRING,
DURIY TYPE STRING,
NOTET TYPE STRING,
NOTLT TYPE STRING,
NOTIM TYPE STRING,
LVAL TYPE STRING,
DELNA TYPE STRING,
LINAT TYPE STRING,
TSIGN TYPE STRING,
TOPTY TYPE STRING,END OF T_EKKO_STR. DATA: WA_PINPEV2_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PINPEV2_STR-MANDT sy-vline
WA_PINPEV2_STR-POGUI sy-vline
WA_PINPEV2_STR-STPID sy-vline
WA_PINPEV2_STR-STDES sy-vline
WA_PINPEV2_STR-ATRID sy-vline
WA_PINPEV2_STR-ATDES sy-vline
WA_PINPEV2_STR-ATSEQ sy-vline
WA_PINPEV2_STR-VLSEQ sy-vline
WA_PINPEV2_STR-ENDDA sy-vline
WA_PINPEV2_STR-BEGDA sy-vline
WA_PINPEV2_STR-SIGN sy-vline
WA_PINPEV2_STR-SGDES sy-vline
WA_PINPEV2_STR-OPTTY sy-vline
WA_PINPEV2_STR-OPDES sy-vline
WA_PINPEV2_STR-LOWVA sy-vline
WA_PINPEV2_STR-HIHVA sy-vline
WA_PINPEV2_STR-UNIT sy-vline
WA_PINPEV2_STR-BVAL sy-vline
WA_PINPEV2_STR-ANDOR sy-vline
WA_PINPEV2_STR-XINDI sy-vline
WA_PINPEV2_STR-DURIY sy-vline
WA_PINPEV2_STR-NOTET sy-vline
WA_PINPEV2_STR-NOTLT sy-vline
WA_PINPEV2_STR-NOTIM sy-vline
WA_PINPEV2_STR-LVAL sy-vline
WA_PINPEV2_STR-DELNA sy-vline
WA_PINPEV2_STR-LINAT sy-vline
WA_PINPEV2_STR-TSIGN sy-vline
WA_PINPEV2_STR-TOPTY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.