ABAP Select data from SAP table PIN_EAST_FLDIN into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PIN_EAST_FLDIN table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PIN_EAST_FLDIN. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PIN_EAST_FLDIN table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PIN_EAST_FLDIN TYPE STANDARD TABLE OF PIN_EAST_FLDIN,
      WA_PIN_EAST_FLDIN TYPE PIN_EAST_FLDIN,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PIN_EAST_FLDIN> TYPE PIN_EAST_FLDIN.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PIN_EAST_FLDIN.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PIN_EAST_FLDIN
  INTO TABLE IT_PIN_EAST_FLDIN.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PIN_EAST_FLDIN
*  INTO TABLE @DATA(IT_PIN_EAST_FLDIN2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PIN_EAST_FLDIN INDEX 1 INTO DATA(WA_PIN_EAST_FLDIN2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PIN_EAST_FLDIN ASSIGNING <PIN_EAST_FLDIN>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PIN_EAST_FLDIN>-EACIN = 1.
<PIN_EAST_FLDIN>-EAHFD = 1.
<PIN_EAST_FLDIN>-EAFSQ = 1.
<PIN_EAST_FLDIN>-EAFTY = 1.
<PIN_EAST_FLDIN>-EAFLB = 1.
ENDLOOP.

LOOP AT IT_PIN_EAST_FLDIN INTO WA_PIN_EAST_FLDIN.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PIN_EAST_FLDIN-EATLP, sy-vline,
WA_PIN_EAST_FLDIN-EAMAN, sy-vline,
WA_PIN_EAST_FLDIN-EAFML, sy-vline,
WA_PIN_EAST_FLDIN-EASHP, sy-vline,
WA_PIN_EAST_FLDIN-EAFMF, sy-vline,
WA_PIN_EAST_FLDIN-EAVEP, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PIN_EAST_FLDIN you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PIN_EAST_FLDIN TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PIN_EAST_FLDIN INTO WA_PIN_EAST_FLDIN. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PIN_EAST_FLDIN_STR,
EACIN TYPE STRING,
EAHFD TYPE STRING,
EAFSQ TYPE STRING,
EAFTY TYPE STRING,
EAFLB TYPE STRING,
EATLP TYPE STRING,
EAMAN TYPE STRING,
EAFML TYPE STRING,
EASHP TYPE STRING,
EAFMF TYPE STRING,
EAVEP TYPE STRING,
EACOL TYPE STRING,
REGEX TYPE STRING,END OF T_EKKO_STR. DATA: WA_PIN_EAST_FLDIN_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PIN_EAST_FLDIN_STR-EACIN sy-vline
WA_PIN_EAST_FLDIN_STR-EAHFD sy-vline
WA_PIN_EAST_FLDIN_STR-EAFSQ sy-vline
WA_PIN_EAST_FLDIN_STR-EAFTY sy-vline
WA_PIN_EAST_FLDIN_STR-EAFLB sy-vline
WA_PIN_EAST_FLDIN_STR-EATLP sy-vline
WA_PIN_EAST_FLDIN_STR-EAMAN sy-vline
WA_PIN_EAST_FLDIN_STR-EAFML sy-vline
WA_PIN_EAST_FLDIN_STR-EASHP sy-vline
WA_PIN_EAST_FLDIN_STR-EAFMF sy-vline
WA_PIN_EAST_FLDIN_STR-EAVEP sy-vline
WA_PIN_EAST_FLDIN_STR-EACOL sy-vline
WA_PIN_EAST_FLDIN_STR-REGEX sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.