ABAP Select data from SAP table PIN_ATCHM into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PIN_ATCHM table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PIN_ATCHM. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PIN_ATCHM table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PIN_ATCHM TYPE STANDARD TABLE OF PIN_ATCHM,
      WA_PIN_ATCHM TYPE PIN_ATCHM,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PIN_ATCHM> TYPE PIN_ATCHM.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PIN_ATCHM.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PIN_ATCHM
  INTO TABLE IT_PIN_ATCHM.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PIN_ATCHM
*  INTO TABLE @DATA(IT_PIN_ATCHM2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PIN_ATCHM INDEX 1 INTO DATA(WA_PIN_ATCHM2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PIN_ATCHM ASSIGNING <PIN_ATCHM>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PIN_ATCHM>-LINUM = 1.
<PIN_ATCHM>-FISTA = 1.
<PIN_ATCHM>-FNAME = 1.
<PIN_ATCHM>-FTYPE = 1.
<PIN_ATCHM>-FSIZE = 1.
ENDLOOP.

LOOP AT IT_PIN_ATCHM INTO WA_PIN_ATCHM.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PIN_ATCHM-SINDX, sy-vline,
WA_PIN_ATCHM-EINDX, sy-vline,
WA_PIN_ATCHM-ISCMP, sy-vline,
WA_PIN_ATCHM-CMPRA, sy-vline,
WA_PIN_ATCHM-INVAF, sy-vline,
ENDLOOP. *Add any further fields from structure WA_PIN_ATCHM you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PIN_ATCHM TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PIN_ATCHM INTO WA_PIN_ATCHM. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PIN_ATCHM_STR,
LINUM TYPE STRING,
FISTA TYPE STRING,
FNAME TYPE STRING,
FTYPE TYPE STRING,
FSIZE TYPE STRING,
SINDX TYPE STRING,
EINDX TYPE STRING,
ISCMP TYPE STRING,
CMPRA TYPE STRING,
INVAF TYPE STRING,END OF T_EKKO_STR. DATA: WA_PIN_ATCHM_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PIN_ATCHM_STR-LINUM sy-vline
WA_PIN_ATCHM_STR-FISTA sy-vline
WA_PIN_ATCHM_STR-FNAME sy-vline
WA_PIN_ATCHM_STR-FTYPE sy-vline
WA_PIN_ATCHM_STR-FSIZE sy-vline
WA_PIN_ATCHM_STR-SINDX sy-vline
WA_PIN_ATCHM_STR-EINDX sy-vline
WA_PIN_ATCHM_STR-ISCMP sy-vline
WA_PIN_ATCHM_STR-CMPRA sy-vline
WA_PIN_ATCHM_STR-INVAF sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.