ABAP Select data from SAP table PHIN_S_HOTO into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PHIN_S_HOTO table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PHIN_S_HOTO. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PHIN_S_HOTO table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PHIN_S_HOTO TYPE STANDARD TABLE OF PHIN_S_HOTO,
      WA_PHIN_S_HOTO TYPE PHIN_S_HOTO,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PHIN_S_HOTO> TYPE PHIN_S_HOTO.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PHIN_S_HOTO.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PHIN_S_HOTO
  INTO TABLE IT_PHIN_S_HOTO.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PHIN_S_HOTO
*  INTO TABLE @DATA(IT_PHIN_S_HOTO2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PHIN_S_HOTO INDEX 1 INTO DATA(WA_PHIN_S_HOTO2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PHIN_S_HOTO ASSIGNING <PHIN_S_HOTO>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PHIN_S_HOTO>-TL_KEY = 1.
<PHIN_S_HOTO>-H_TL_KEY = 1.
<PHIN_S_HOTO>-INDIVIDUALMATERIALID = 1.
<PHIN_S_HOTO>-INDIVIDUALMATERIALDESCRIPTION = 1.
<PHIN_S_HOTO>-INDIVIDUALMATERIALCATEGORYCODE = 1.
ENDLOOP.

LOOP AT IT_PHIN_S_HOTO INTO WA_PHIN_S_HOTO.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PHIN_S_HOTO-SUPERIORINDIVIDUALMATERIALID, sy-vline,
WA_PHIN_S_HOTO-INSTALLATIONPOINTID, sy-vline,
WA_PHIN_S_HOTO-INSTALLATIONPOINTDESCRIPTION, sy-vline,
WA_PHIN_S_HOTO-INSTALLATIONPOINTCATEGORYCODE, sy-vline,
WA_PHIN_S_HOTO-SUPERIORINSTALLATIONPOINTID, sy-vline,
WA_PHIN_S_HOTO-KMATN, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PHIN_S_HOTO you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PHIN_S_HOTO TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PHIN_S_HOTO INTO WA_PHIN_S_HOTO. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field INDIVIDUALMATERIALID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PHIN_S_HOTO-INDIVIDUALMATERIALID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PHIN_S_HOTO-INDIVIDUALMATERIALID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SUPERIORINDIVIDUALMATERIALID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PHIN_S_HOTO-SUPERIORINDIVIDUALMATERIALID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PHIN_S_HOTO-SUPERIORINDIVIDUALMATERIALID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field SUPERIORINSTALLATIONPOINTID CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_PHIN_S_HOTO-SUPERIORINSTALLATIONPOINTID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PHIN_S_HOTO-SUPERIORINSTALLATIONPOINTID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field KMATN CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_PHIN_S_HOTO-KMATN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PHIN_S_HOTO-KMATN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATNL, internal->external for field PRODUCTID CALL FUNCTION 'CONVERSION_EXIT_MATNL_OUTPUT' EXPORTING input = WA_PHIN_S_HOTO-PRODUCTID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PHIN_S_HOTO-PRODUCTID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GERNR, internal->external for field SERIALID CALL FUNCTION 'CONVERSION_EXIT_GERNR_OUTPUT' EXPORTING input = WA_PHIN_S_HOTO-SERIALID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PHIN_S_HOTO-SERIALID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATNL, internal->external for field SUPERIORPRODUCTID CALL FUNCTION 'CONVERSION_EXIT_MATNL_OUTPUT' EXPORTING input = WA_PHIN_S_HOTO-SUPERIORPRODUCTID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PHIN_S_HOTO-SUPERIORPRODUCTID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GERNR, internal->external for field SUPERIORSERIALID CALL FUNCTION 'CONVERSION_EXIT_GERNR_OUTPUT' EXPORTING input = WA_PHIN_S_HOTO-SUPERIORSERIALID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PHIN_S_HOTO-SUPERIORSERIALID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field LANGUAGE CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_PHIN_S_HOTO-LANGUAGE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PHIN_S_HOTO-LANGUAGE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEASUREUNITCODE CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PHIN_S_HOTO-MEASUREUNITCODE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PHIN_S_HOTO-MEASUREUNITCODE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field CONSTRUCTIONYEAR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_PHIN_S_HOTO-CONSTRUCTIONYEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PHIN_S_HOTO-CONSTRUCTIONYEAR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PHIN_S_HOTO_STR,
TL_KEY TYPE STRING,
H_TL_KEY TYPE STRING,
INDIVIDUALMATERIALID TYPE STRING,
INDIVIDUALMATERIALDESCRIPTION TYPE STRING,
INDIVIDUALMATERIALCATEGORYCODE TYPE STRING,
SUPERIORINDIVIDUALMATERIALID TYPE STRING,
INSTALLATIONPOINTID TYPE STRING,
INSTALLATIONPOINTDESCRIPTION TYPE STRING,
INSTALLATIONPOINTCATEGORYCODE TYPE STRING,
SUPERIORINSTALLATIONPOINTID TYPE STRING,
KMATN TYPE STRING,
FUNCID TYPE STRING,
PRODUCTID TYPE STRING,
RECENT_MATNR TYPE STRING,
PRODUCTDESCRIPTION TYPE STRING,
SERIALID TYPE STRING,
SUPERIORPRODUCTID TYPE STRING,
SUPERIORSERIALID TYPE STRING,
VALIDONDATE TYPE STRING,
FUNCTIONIDENTIFIER TYPE STRING,
LANGUAGE TYPE STRING,
QUANTITY TYPE STRING,
MEASUREUNITCODE TYPE STRING,
LOCATIONID TYPE STRING,
CONSTRUCTIONYEAR TYPE STRING,
CONSTRUCTIONMONTH TYPE STRING,
INSTALLATIONDATE TYPE STRING,
DISMANTLEDATE TYPE STRING,
TIMESINCENEW_VALUE TYPE STRING,
TIMESINCENEW_DATE TYPE STRING,
CYCLESSINCENEW_VALUE TYPE STRING,
CYCLESSINCENEW_DATE TYPE STRING,
DAYSSINCENEW_VALUE TYPE STRING,
DAYSSINCENEW_DATE TYPE STRING,
TIMESINCEOVERHAUL_VALUE TYPE STRING,
TIMESINCEOVERHAUL_DATE TYPE STRING,
CYCLESSINCEOVERHAUL_VALUE TYPE STRING,
CYCLESSINCEOVERHAUL_DATE TYPE STRING,
DAYSSINCEOVERHAUL_VALUE TYPE STRING,
DAYSSINCEOVERHAUL_DATE TYPE STRING,
TIMESINCEREPAIR_VALUE TYPE STRING,
TIMESINCEREPAIR_DATE TYPE STRING,
CYCLESSINCEREPAIR_VALUE TYPE STRING,
CYCLESSINCEREPAIR_DATE TYPE STRING,
DAYSSINCEREPAIR_VALUE TYPE STRING,
DAYSSINCEREPAIR_DATE TYPE STRING,
UII TYPE STRING,END OF T_EKKO_STR. DATA: WA_PHIN_S_HOTO_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PHIN_S_HOTO_STR-TL_KEY sy-vline
WA_PHIN_S_HOTO_STR-H_TL_KEY sy-vline
WA_PHIN_S_HOTO_STR-INDIVIDUALMATERIALID sy-vline
WA_PHIN_S_HOTO_STR-INDIVIDUALMATERIALDESCRIPTION sy-vline
WA_PHIN_S_HOTO_STR-INDIVIDUALMATERIALCATEGORYCODE sy-vline
WA_PHIN_S_HOTO_STR-SUPERIORINDIVIDUALMATERIALID sy-vline
WA_PHIN_S_HOTO_STR-INSTALLATIONPOINTID sy-vline
WA_PHIN_S_HOTO_STR-INSTALLATIONPOINTDESCRIPTION sy-vline
WA_PHIN_S_HOTO_STR-INSTALLATIONPOINTCATEGORYCODE sy-vline
WA_PHIN_S_HOTO_STR-SUPERIORINSTALLATIONPOINTID sy-vline
WA_PHIN_S_HOTO_STR-KMATN sy-vline
WA_PHIN_S_HOTO_STR-FUNCID sy-vline
WA_PHIN_S_HOTO_STR-PRODUCTID sy-vline
WA_PHIN_S_HOTO_STR-RECENT_MATNR sy-vline
WA_PHIN_S_HOTO_STR-PRODUCTDESCRIPTION sy-vline
WA_PHIN_S_HOTO_STR-SERIALID sy-vline
WA_PHIN_S_HOTO_STR-SUPERIORPRODUCTID sy-vline
WA_PHIN_S_HOTO_STR-SUPERIORSERIALID sy-vline
WA_PHIN_S_HOTO_STR-VALIDONDATE sy-vline
WA_PHIN_S_HOTO_STR-FUNCTIONIDENTIFIER sy-vline
WA_PHIN_S_HOTO_STR-LANGUAGE sy-vline
WA_PHIN_S_HOTO_STR-QUANTITY sy-vline
WA_PHIN_S_HOTO_STR-MEASUREUNITCODE sy-vline
WA_PHIN_S_HOTO_STR-LOCATIONID sy-vline
WA_PHIN_S_HOTO_STR-CONSTRUCTIONYEAR sy-vline
WA_PHIN_S_HOTO_STR-CONSTRUCTIONMONTH sy-vline
WA_PHIN_S_HOTO_STR-INSTALLATIONDATE sy-vline
WA_PHIN_S_HOTO_STR-DISMANTLEDATE sy-vline
WA_PHIN_S_HOTO_STR-TIMESINCENEW_VALUE sy-vline
WA_PHIN_S_HOTO_STR-TIMESINCENEW_DATE sy-vline
WA_PHIN_S_HOTO_STR-CYCLESSINCENEW_VALUE sy-vline
WA_PHIN_S_HOTO_STR-CYCLESSINCENEW_DATE sy-vline
WA_PHIN_S_HOTO_STR-DAYSSINCENEW_VALUE sy-vline
WA_PHIN_S_HOTO_STR-DAYSSINCENEW_DATE sy-vline
WA_PHIN_S_HOTO_STR-TIMESINCEOVERHAUL_VALUE sy-vline
WA_PHIN_S_HOTO_STR-TIMESINCEOVERHAUL_DATE sy-vline
WA_PHIN_S_HOTO_STR-CYCLESSINCEOVERHAUL_VALUE sy-vline
WA_PHIN_S_HOTO_STR-CYCLESSINCEOVERHAUL_DATE sy-vline
WA_PHIN_S_HOTO_STR-DAYSSINCEOVERHAUL_VALUE sy-vline
WA_PHIN_S_HOTO_STR-DAYSSINCEOVERHAUL_DATE sy-vline
WA_PHIN_S_HOTO_STR-TIMESINCEREPAIR_VALUE sy-vline
WA_PHIN_S_HOTO_STR-TIMESINCEREPAIR_DATE sy-vline
WA_PHIN_S_HOTO_STR-CYCLESSINCEREPAIR_VALUE sy-vline
WA_PHIN_S_HOTO_STR-CYCLESSINCEREPAIR_DATE sy-vline
WA_PHIN_S_HOTO_STR-DAYSSINCEREPAIR_VALUE sy-vline
WA_PHIN_S_HOTO_STR-DAYSSINCEREPAIR_DATE sy-vline
WA_PHIN_S_HOTO_STR-UII sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.