ABAP Select data from SAP table PGMAVCOCOUSEENH into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PGMAVCOCOUSEENH table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PGMAVCOCOUSEENH. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PGMAVCOCOUSEENH table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PGMAVCOCOUSEENH TYPE STANDARD TABLE OF PGMAVCOCOUSEENH,
      WA_PGMAVCOCOUSEENH TYPE PGMAVCOCOUSEENH,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PGMAVCOCOUSEENH> TYPE PGMAVCOCOUSEENH.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PGMAVCOCOUSEENH.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PGMAVCOCOUSEENH
  INTO TABLE IT_PGMAVCOCOUSEENH.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PGMAVCOCOUSEENH
*  INTO TABLE @DATA(IT_PGMAVCOCOUSEENH2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PGMAVCOCOUSEENH INDEX 1 INTO DATA(WA_PGMAVCOCOUSEENH2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PGMAVCOCOUSEENH ASSIGNING <PGMAVCOCOUSEENH>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PGMAVCOCOUSEENH>-MANDT = 1.
<PGMAVCOCOUSEENH>-RBUKRS = 1.
<PGMAVCOCOUSEENH>-RLDNR = 1.
<PGMAVCOCOUSEENH>-RGRANT_NBR = 1.
<PGMAVCOCOUSEENH>-RFUND = 1.
ENDLOOP.

LOOP AT IT_PGMAVCOCOUSEENH INTO WA_PGMAVCOCOUSEENH.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PGMAVCOCOUSEENH-RSPONSORED_PROG, sy-vline,
WA_PGMAVCOCOUSEENH-RSPONSORED_CLASS, sy-vline,
WA_PGMAVCOCOUSEENH-RBDGT_VLDTY_NBR, sy-vline,
WA_PGMAVCOCOUSEENH-RTCUR, sy-vline,
WA_PGMAVCOCOUSEENH-CONSUMABLEAMOUNTINCCCRCY, sy-vline,
WA_PGMAVCOCOUSEENH-CONSUMEDAMOUNTINCCCRCY, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PGMAVCOCOUSEENH you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PGMAVCOCOUSEENH TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PGMAVCOCOUSEENH INTO WA_PGMAVCOCOUSEENH. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field RLDNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PGMAVCOCOUSEENH-RLDNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PGMAVCOCOUSEENH-RLDNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RGRANT_NBR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PGMAVCOCOUSEENH-RGRANT_NBR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PGMAVCOCOUSEENH-RGRANT_NBR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PGMAVCOCOUSEENH_STR,
MANDT TYPE STRING,
RBUKRS TYPE STRING,
RLDNR TYPE STRING,
RGRANT_NBR TYPE STRING,
RFUND TYPE STRING,
RSPONSORED_PROG TYPE STRING,
RSPONSORED_CLASS TYPE STRING,
RBDGT_VLDTY_NBR TYPE STRING,
RTCUR TYPE STRING,
CONSUMABLEAMOUNTINCCCRCY TYPE STRING,
CONSUMEDAMOUNTINCCCRCY TYPE STRING,
AVAILABLEAMOUNTINCCCRCY TYPE STRING,
HUNDREDTIMESAVAILAMOUNTINCCCRY TYPE STRING,
XPERCENTAVAILABLEAMOUNTINCCCRY TYPE STRING,
CONSUMABLEAMOUNTINGRANTCRCY TYPE STRING,
CONSUMEDAMOUNTINGRANTCRCY TYPE STRING,
AVAILABLEAMOUNTINGRANTCRCY TYPE STRING,
HUNDREDTIMESAVAILAMTINGRANTCRY TYPE STRING,
XPERCENTAVAILAMOUNTINGRANTCRY TYPE STRING,
NUMBEROFCONTROLOBJECTS TYPE STRING,END OF T_EKKO_STR. DATA: WA_PGMAVCOCOUSEENH_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PGMAVCOCOUSEENH_STR-MANDT sy-vline
WA_PGMAVCOCOUSEENH_STR-RBUKRS sy-vline
WA_PGMAVCOCOUSEENH_STR-RLDNR sy-vline
WA_PGMAVCOCOUSEENH_STR-RGRANT_NBR sy-vline
WA_PGMAVCOCOUSEENH_STR-RFUND sy-vline
WA_PGMAVCOCOUSEENH_STR-RSPONSORED_PROG sy-vline
WA_PGMAVCOCOUSEENH_STR-RSPONSORED_CLASS sy-vline
WA_PGMAVCOCOUSEENH_STR-RBDGT_VLDTY_NBR sy-vline
WA_PGMAVCOCOUSEENH_STR-RTCUR sy-vline
WA_PGMAVCOCOUSEENH_STR-CONSUMABLEAMOUNTINCCCRCY sy-vline
WA_PGMAVCOCOUSEENH_STR-CONSUMEDAMOUNTINCCCRCY sy-vline
WA_PGMAVCOCOUSEENH_STR-AVAILABLEAMOUNTINCCCRCY sy-vline
WA_PGMAVCOCOUSEENH_STR-HUNDREDTIMESAVAILAMOUNTINCCCRY sy-vline
WA_PGMAVCOCOUSEENH_STR-XPERCENTAVAILABLEAMOUNTINCCCRY sy-vline
WA_PGMAVCOCOUSEENH_STR-CONSUMABLEAMOUNTINGRANTCRCY sy-vline
WA_PGMAVCOCOUSEENH_STR-CONSUMEDAMOUNTINGRANTCRCY sy-vline
WA_PGMAVCOCOUSEENH_STR-AVAILABLEAMOUNTINGRANTCRCY sy-vline
WA_PGMAVCOCOUSEENH_STR-HUNDREDTIMESAVAILAMTINGRANTCRY sy-vline
WA_PGMAVCOCOUSEENH_STR-XPERCENTAVAILAMOUNTINGRANTCRY sy-vline
WA_PGMAVCOCOUSEENH_STR-NUMBEROFCONTROLOBJECTS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.