ABAP Select data from SAP table PFMAVCT_OLD into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PFMAVCT_OLD table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PFMAVCT_OLD. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PFMAVCT_OLD table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PFMAVCT_OLD TYPE STANDARD TABLE OF PFMAVCT_OLD,
      WA_PFMAVCT_OLD TYPE PFMAVCT_OLD,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PFMAVCT_OLD> TYPE PFMAVCT_OLD.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PFMAVCT_OLD.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PFMAVCT_OLD
  INTO TABLE IT_PFMAVCT_OLD.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PFMAVCT_OLD
*  INTO TABLE @DATA(IT_PFMAVCT_OLD2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PFMAVCT_OLD INDEX 1 INTO DATA(WA_PFMAVCT_OLD2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PFMAVCT_OLD ASSIGNING <PFMAVCT_OLD>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PFMAVCT_OLD>-RCLNT = 1.
<PFMAVCT_OLD>-RLDNR = 1.
<PFMAVCT_OLD>-RRCTY = 1.
<PFMAVCT_OLD>-RVERS = 1.
<PFMAVCT_OLD>-RYEAR = 1.
ENDLOOP.

LOOP AT IT_PFMAVCT_OLD INTO WA_PFMAVCT_OLD.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PFMAVCT_OLD-ROBJNR, sy-vline,
WA_PFMAVCT_OLD-COBJNR, sy-vline,
WA_PFMAVCT_OLD-SOBJNR, sy-vline,
WA_PFMAVCT_OLD-RTCUR, sy-vline,
WA_PFMAVCT_OLD-DRCRK, sy-vline,
WA_PFMAVCT_OLD-RPMAX, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PFMAVCT_OLD you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PFMAVCT_OLD TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PFMAVCT_OLD INTO WA_PFMAVCT_OLD. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field RLDNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PFMAVCT_OLD-RLDNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PFMAVCT_OLD-RLDNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RVERS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PFMAVCT_OLD-RVERS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PFMAVCT_OLD-RVERS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field RYEAR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_PFMAVCT_OLD-RYEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PFMAVCT_OLD-RYEAR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit FMCIL, internal->external for field RCMMTITEM CALL FUNCTION 'CONVERSION_EXIT_FMCIL_OUTPUT' EXPORTING input = WA_PFMAVCT_OLD-RCMMTITEM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PFMAVCT_OLD-RCMMTITEM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RGRANT_NBR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PFMAVCT_OLD-RGRANT_NBR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PFMAVCT_OLD-RGRANT_NBR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field CEFFYEAR_9 CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_PFMAVCT_OLD-CEFFYEAR_9 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PFMAVCT_OLD-CEFFYEAR_9.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LOGSYS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PFMAVCT_OLD-LOGSYS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PFMAVCT_OLD-LOGSYS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field KSLVT CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_PFMAVCT_OLD-KSLVT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PFMAVCT_OLD-KSLVT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field KSL01 CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_PFMAVCT_OLD-KSL01 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PFMAVCT_OLD-KSL01.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field KSL02 CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_PFMAVCT_OLD-KSL02 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PFMAVCT_OLD-KSL02.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field KSL03 CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_PFMAVCT_OLD-KSL03 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PFMAVCT_OLD-KSL03.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field KSL04 CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_PFMAVCT_OLD-KSL04 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PFMAVCT_OLD-KSL04.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field KSL05 CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_PFMAVCT_OLD-KSL05 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PFMAVCT_OLD-KSL05.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field KSL06 CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_PFMAVCT_OLD-KSL06 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PFMAVCT_OLD-KSL06.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field KSL07 CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_PFMAVCT_OLD-KSL07 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PFMAVCT_OLD-KSL07.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field KSL08 CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_PFMAVCT_OLD-KSL08 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PFMAVCT_OLD-KSL08.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field KSL09 CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_PFMAVCT_OLD-KSL09 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PFMAVCT_OLD-KSL09.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field KSL10 CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_PFMAVCT_OLD-KSL10 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PFMAVCT_OLD-KSL10.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field KSL11 CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_PFMAVCT_OLD-KSL11 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PFMAVCT_OLD-KSL11.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field KSL12 CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_PFMAVCT_OLD-KSL12 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PFMAVCT_OLD-KSL12.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field KSL13 CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_PFMAVCT_OLD-KSL13 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PFMAVCT_OLD-KSL13.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field KSL14 CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_PFMAVCT_OLD-KSL14 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PFMAVCT_OLD-KSL14.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field KSL15 CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_PFMAVCT_OLD-KSL15 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PFMAVCT_OLD-KSL15.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field KSL16 CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_PFMAVCT_OLD-KSL16 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PFMAVCT_OLD-KSL16.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PFMAVCT_OLD_STR,
RCLNT TYPE STRING,
RLDNR TYPE STRING,
RRCTY TYPE STRING,
RVERS TYPE STRING,
RYEAR TYPE STRING,
ROBJNR TYPE STRING,
COBJNR TYPE STRING,
SOBJNR TYPE STRING,
RTCUR TYPE STRING,
DRCRK TYPE STRING,
RPMAX TYPE STRING,
RFIKRS TYPE STRING,
RFUND TYPE STRING,
RFUNDSCTR TYPE STRING,
RCMMTITEM TYPE STRING,
RFUNCAREA TYPE STRING,
RUSERDIM TYPE STRING,
RGRANT_NBR TYPE STRING,
RMEASURE TYPE STRING,
RCVRGRP_9 TYPE STRING,
BUDGET_PD_9 TYPE STRING,
CEFFYEAR_9 TYPE STRING,
WFSTATE_9 TYPE STRING,
ALLOCTYPE_9 TYPE STRING,
LOGSYS TYPE STRING,
TSLVT TYPE STRING,
TSL01 TYPE STRING,
TSL02 TYPE STRING,
TSL03 TYPE STRING,
TSL04 TYPE STRING,
TSL05 TYPE STRING,
TSL06 TYPE STRING,
TSL07 TYPE STRING,
TSL08 TYPE STRING,
TSL09 TYPE STRING,
TSL10 TYPE STRING,
TSL11 TYPE STRING,
TSL12 TYPE STRING,
TSL13 TYPE STRING,
TSL14 TYPE STRING,
TSL15 TYPE STRING,
TSL16 TYPE STRING,
HSLVT TYPE STRING,
HSL01 TYPE STRING,
HSL02 TYPE STRING,
HSL03 TYPE STRING,
HSL04 TYPE STRING,
HSL05 TYPE STRING,
HSL06 TYPE STRING,
HSL07 TYPE STRING,
HSL08 TYPE STRING,
HSL09 TYPE STRING,
HSL10 TYPE STRING,
HSL11 TYPE STRING,
HSL12 TYPE STRING,
HSL13 TYPE STRING,
HSL14 TYPE STRING,
HSL15 TYPE STRING,
HSL16 TYPE STRING,
KSLVT TYPE STRING,
KSL01 TYPE STRING,
KSL02 TYPE STRING,
KSL03 TYPE STRING,
KSL04 TYPE STRING,
KSL05 TYPE STRING,
KSL06 TYPE STRING,
KSL07 TYPE STRING,
KSL08 TYPE STRING,
KSL09 TYPE STRING,
KSL10 TYPE STRING,
KSL11 TYPE STRING,
KSL12 TYPE STRING,
KSL13 TYPE STRING,
KSL14 TYPE STRING,
KSL15 TYPE STRING,
KSL16 TYPE STRING,
CSPRED TYPE STRING,END OF T_EKKO_STR. DATA: WA_PFMAVCT_OLD_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PFMAVCT_OLD_STR-RCLNT sy-vline
WA_PFMAVCT_OLD_STR-RLDNR sy-vline
WA_PFMAVCT_OLD_STR-RRCTY sy-vline
WA_PFMAVCT_OLD_STR-RVERS sy-vline
WA_PFMAVCT_OLD_STR-RYEAR sy-vline
WA_PFMAVCT_OLD_STR-ROBJNR sy-vline
WA_PFMAVCT_OLD_STR-COBJNR sy-vline
WA_PFMAVCT_OLD_STR-SOBJNR sy-vline
WA_PFMAVCT_OLD_STR-RTCUR sy-vline
WA_PFMAVCT_OLD_STR-DRCRK sy-vline
WA_PFMAVCT_OLD_STR-RPMAX sy-vline
WA_PFMAVCT_OLD_STR-RFIKRS sy-vline
WA_PFMAVCT_OLD_STR-RFUND sy-vline
WA_PFMAVCT_OLD_STR-RFUNDSCTR sy-vline
WA_PFMAVCT_OLD_STR-RCMMTITEM sy-vline
WA_PFMAVCT_OLD_STR-RFUNCAREA sy-vline
WA_PFMAVCT_OLD_STR-RUSERDIM sy-vline
WA_PFMAVCT_OLD_STR-RGRANT_NBR sy-vline
WA_PFMAVCT_OLD_STR-RMEASURE sy-vline
WA_PFMAVCT_OLD_STR-RCVRGRP_9 sy-vline
WA_PFMAVCT_OLD_STR-BUDGET_PD_9 sy-vline
WA_PFMAVCT_OLD_STR-CEFFYEAR_9 sy-vline
WA_PFMAVCT_OLD_STR-WFSTATE_9 sy-vline
WA_PFMAVCT_OLD_STR-ALLOCTYPE_9 sy-vline
WA_PFMAVCT_OLD_STR-LOGSYS sy-vline
WA_PFMAVCT_OLD_STR-TSLVT sy-vline
WA_PFMAVCT_OLD_STR-TSL01 sy-vline
WA_PFMAVCT_OLD_STR-TSL02 sy-vline
WA_PFMAVCT_OLD_STR-TSL03 sy-vline
WA_PFMAVCT_OLD_STR-TSL04 sy-vline
WA_PFMAVCT_OLD_STR-TSL05 sy-vline
WA_PFMAVCT_OLD_STR-TSL06 sy-vline
WA_PFMAVCT_OLD_STR-TSL07 sy-vline
WA_PFMAVCT_OLD_STR-TSL08 sy-vline
WA_PFMAVCT_OLD_STR-TSL09 sy-vline
WA_PFMAVCT_OLD_STR-TSL10 sy-vline
WA_PFMAVCT_OLD_STR-TSL11 sy-vline
WA_PFMAVCT_OLD_STR-TSL12 sy-vline
WA_PFMAVCT_OLD_STR-TSL13 sy-vline
WA_PFMAVCT_OLD_STR-TSL14 sy-vline
WA_PFMAVCT_OLD_STR-TSL15 sy-vline
WA_PFMAVCT_OLD_STR-TSL16 sy-vline
WA_PFMAVCT_OLD_STR-HSLVT sy-vline
WA_PFMAVCT_OLD_STR-HSL01 sy-vline
WA_PFMAVCT_OLD_STR-HSL02 sy-vline
WA_PFMAVCT_OLD_STR-HSL03 sy-vline
WA_PFMAVCT_OLD_STR-HSL04 sy-vline
WA_PFMAVCT_OLD_STR-HSL05 sy-vline
WA_PFMAVCT_OLD_STR-HSL06 sy-vline
WA_PFMAVCT_OLD_STR-HSL07 sy-vline
WA_PFMAVCT_OLD_STR-HSL08 sy-vline
WA_PFMAVCT_OLD_STR-HSL09 sy-vline
WA_PFMAVCT_OLD_STR-HSL10 sy-vline
WA_PFMAVCT_OLD_STR-HSL11 sy-vline
WA_PFMAVCT_OLD_STR-HSL12 sy-vline
WA_PFMAVCT_OLD_STR-HSL13 sy-vline
WA_PFMAVCT_OLD_STR-HSL14 sy-vline
WA_PFMAVCT_OLD_STR-HSL15 sy-vline
WA_PFMAVCT_OLD_STR-HSL16 sy-vline
WA_PFMAVCT_OLD_STR-KSLVT sy-vline
WA_PFMAVCT_OLD_STR-KSL01 sy-vline
WA_PFMAVCT_OLD_STR-KSL02 sy-vline
WA_PFMAVCT_OLD_STR-KSL03 sy-vline
WA_PFMAVCT_OLD_STR-KSL04 sy-vline
WA_PFMAVCT_OLD_STR-KSL05 sy-vline
WA_PFMAVCT_OLD_STR-KSL06 sy-vline
WA_PFMAVCT_OLD_STR-KSL07 sy-vline
WA_PFMAVCT_OLD_STR-KSL08 sy-vline
WA_PFMAVCT_OLD_STR-KSL09 sy-vline
WA_PFMAVCT_OLD_STR-KSL10 sy-vline
WA_PFMAVCT_OLD_STR-KSL11 sy-vline
WA_PFMAVCT_OLD_STR-KSL12 sy-vline
WA_PFMAVCT_OLD_STR-KSL13 sy-vline
WA_PFMAVCT_OLD_STR-KSL14 sy-vline
WA_PFMAVCT_OLD_STR-KSL15 sy-vline
WA_PFMAVCT_OLD_STR-KSL16 sy-vline
WA_PFMAVCT_OLD_STR-CSPRED sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.