ABAP Select data from SAP table PFM_12FIE_BSEG_REWIND into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PFM_12FIE_BSEG_REWIND table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PFM_12FIE_BSEG_REWIND. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PFM_12FIE_BSEG_REWIND table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PFM_12FIE_BSEG_REWIND TYPE STANDARD TABLE OF PFM_12FIE_BSEG_REWIND,
      WA_PFM_12FIE_BSEG_REWIND TYPE PFM_12FIE_BSEG_REWIND,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PFM_12FIE_BSEG_REWIND> TYPE PFM_12FIE_BSEG_REWIND.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PFM_12FIE_BSEG_REWIND.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PFM_12FIE_BSEG_REWIND
  INTO TABLE IT_PFM_12FIE_BSEG_REWIND.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PFM_12FIE_BSEG_REWIND
*  INTO TABLE @DATA(IT_PFM_12FIE_BSEG_REWIND2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PFM_12FIE_BSEG_REWIND INDEX 1 INTO DATA(WA_PFM_12FIE_BSEG_REWIND2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PFM_12FIE_BSEG_REWIND ASSIGNING <PFM_12FIE_BSEG_REWIND>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PFM_12FIE_BSEG_REWIND>-BUKRS = 1.
<PFM_12FIE_BSEG_REWIND>-BELNR = 1.
<PFM_12FIE_BSEG_REWIND>-GJAHR = 1.
<PFM_12FIE_BSEG_REWIND>-BUZEI = 1.
<PFM_12FIE_BSEG_REWIND>-HKONT = 1.
ENDLOOP.

LOOP AT IT_PFM_12FIE_BSEG_REWIND INTO WA_PFM_12FIE_BSEG_REWIND.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PFM_12FIE_BSEG_REWIND-KOART, sy-vline,
WA_PFM_12FIE_BSEG_REWIND-KBLNR, sy-vline,
WA_PFM_12FIE_BSEG_REWIND-KBLPOS, sy-vline,
WA_PFM_12FIE_BSEG_REWIND-FISTL, sy-vline,
WA_PFM_12FIE_BSEG_REWIND-FIPOS, sy-vline,
WA_PFM_12FIE_BSEG_REWIND-GEBER, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PFM_12FIE_BSEG_REWIND you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PFM_12FIE_BSEG_REWIND TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PFM_12FIE_BSEG_REWIND INTO WA_PFM_12FIE_BSEG_REWIND. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field BELNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PFM_12FIE_BSEG_REWIND-BELNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PFM_12FIE_BSEG_REWIND-BELNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field GJAHR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_PFM_12FIE_BSEG_REWIND-GJAHR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PFM_12FIE_BSEG_REWIND-GJAHR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field HKONT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PFM_12FIE_BSEG_REWIND-HKONT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PFM_12FIE_BSEG_REWIND-HKONT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KBLNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PFM_12FIE_BSEG_REWIND-KBLNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PFM_12FIE_BSEG_REWIND-KBLNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LIFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PFM_12FIE_BSEG_REWIND-LIFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PFM_12FIE_BSEG_REWIND-LIFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EMPFB CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PFM_12FIE_BSEG_REWIND-EMPFB IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PFM_12FIE_BSEG_REWIND-EMPFB.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AUGBL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PFM_12FIE_BSEG_REWIND-AUGBL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PFM_12FIE_BSEG_REWIND-AUGBL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field AUGGJ CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_PFM_12FIE_BSEG_REWIND-AUGGJ IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PFM_12FIE_BSEG_REWIND-AUGGJ.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field REBZG CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PFM_12FIE_BSEG_REWIND-REBZG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PFM_12FIE_BSEG_REWIND-REBZG.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field REBZJ CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_PFM_12FIE_BSEG_REWIND-REBZJ IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PFM_12FIE_BSEG_REWIND-REBZJ.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PFM_12FIE_BSEG_REWIND_STR,
BUKRS TYPE STRING,
BELNR TYPE STRING,
GJAHR TYPE STRING,
BUZEI TYPE STRING,
HKONT TYPE STRING,
KOART TYPE STRING,
KBLNR TYPE STRING,
KBLPOS TYPE STRING,
FISTL TYPE STRING,
FIPOS TYPE STRING,
GEBER TYPE STRING,
LIFNR TYPE STRING,
XREF3 TYPE STRING,
DMBTR TYPE STRING,
SHKZG TYPE STRING,
EMPFB TYPE STRING,
AUGBL TYPE STRING,
AUGGJ TYPE STRING,
AUGDT TYPE STRING,
MWSKZ TYPE STRING,
REBZG TYPE STRING,
REBZJ TYPE STRING,
UMSKZ TYPE STRING,
BUZID TYPE STRING,
FWBAS TYPE STRING,
FLG_LINK TYPE STRING,END OF T_EKKO_STR. DATA: WA_PFM_12FIE_BSEG_REWIND_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PFM_12FIE_BSEG_REWIND_STR-BUKRS sy-vline
WA_PFM_12FIE_BSEG_REWIND_STR-BELNR sy-vline
WA_PFM_12FIE_BSEG_REWIND_STR-GJAHR sy-vline
WA_PFM_12FIE_BSEG_REWIND_STR-BUZEI sy-vline
WA_PFM_12FIE_BSEG_REWIND_STR-HKONT sy-vline
WA_PFM_12FIE_BSEG_REWIND_STR-KOART sy-vline
WA_PFM_12FIE_BSEG_REWIND_STR-KBLNR sy-vline
WA_PFM_12FIE_BSEG_REWIND_STR-KBLPOS sy-vline
WA_PFM_12FIE_BSEG_REWIND_STR-FISTL sy-vline
WA_PFM_12FIE_BSEG_REWIND_STR-FIPOS sy-vline
WA_PFM_12FIE_BSEG_REWIND_STR-GEBER sy-vline
WA_PFM_12FIE_BSEG_REWIND_STR-LIFNR sy-vline
WA_PFM_12FIE_BSEG_REWIND_STR-XREF3 sy-vline
WA_PFM_12FIE_BSEG_REWIND_STR-DMBTR sy-vline
WA_PFM_12FIE_BSEG_REWIND_STR-SHKZG sy-vline
WA_PFM_12FIE_BSEG_REWIND_STR-EMPFB sy-vline
WA_PFM_12FIE_BSEG_REWIND_STR-AUGBL sy-vline
WA_PFM_12FIE_BSEG_REWIND_STR-AUGGJ sy-vline
WA_PFM_12FIE_BSEG_REWIND_STR-AUGDT sy-vline
WA_PFM_12FIE_BSEG_REWIND_STR-MWSKZ sy-vline
WA_PFM_12FIE_BSEG_REWIND_STR-REBZG sy-vline
WA_PFM_12FIE_BSEG_REWIND_STR-REBZJ sy-vline
WA_PFM_12FIE_BSEG_REWIND_STR-UMSKZ sy-vline
WA_PFM_12FIE_BSEG_REWIND_STR-BUZID sy-vline
WA_PFM_12FIE_BSEG_REWIND_STR-FWBAS sy-vline
WA_PFM_12FIE_BSEG_REWIND_STR-FLG_LINK sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.