ABAP Select data from SAP table PEQUIFLOCUNION into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PEQUIFLOCUNION table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PEQUIFLOCUNION. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PEQUIFLOCUNION table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PEQUIFLOCUNION TYPE STANDARD TABLE OF PEQUIFLOCUNION,
      WA_PEQUIFLOCUNION TYPE PEQUIFLOCUNION,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PEQUIFLOCUNION> TYPE PEQUIFLOCUNION.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PEQUIFLOCUNION.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PEQUIFLOCUNION
  INTO TABLE IT_PEQUIFLOCUNION.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PEQUIFLOCUNION
*  INTO TABLE @DATA(IT_PEQUIFLOCUNION2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PEQUIFLOCUNION INDEX 1 INTO DATA(WA_PEQUIFLOCUNION2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PEQUIFLOCUNION ASSIGNING <PEQUIFLOCUNION>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PEQUIFLOCUNION>-MANDT = 1.
<PEQUIFLOCUNION>-TECHNICALOBJECT = 1.
<PEQUIFLOCUNION>-TECHOBJISEQUIPORFUNCNLLOC = 1.
<PEQUIFLOCUNION>-EQUIPMENT = 1.
<PEQUIFLOCUNION>-FUNCTIONALLOCATION = 1.
ENDLOOP.

LOOP AT IT_PEQUIFLOCUNION INTO WA_PEQUIFLOCUNION.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PEQUIFLOCUNION-TECHNICALOBJECTCATEGORY, sy-vline,
WA_PEQUIFLOCUNION-TECHNICALOBJECTTYPE, sy-vline,
WA_PEQUIFLOCUNION-CREATEDBYUSER, sy-vline,
WA_PEQUIFLOCUNION-CREATIONDATE, sy-vline,
WA_PEQUIFLOCUNION-LASTCHANGEDBYUSER, sy-vline,
WA_PEQUIFLOCUNION-LASTCHANGEDATE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PEQUIFLOCUNION you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PEQUIFLOCUNION TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PEQUIFLOCUNION INTO WA_PEQUIFLOCUNION. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field EQUIPMENT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PEQUIFLOCUNION-EQUIPMENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PEQUIFLOCUNION-EQUIPMENT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field FUNCTIONALLOCATION CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_PEQUIFLOCUNION-FUNCTIONALLOCATION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PEQUIFLOCUNION-FUNCTIONALLOCATION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field CONSTRUCTIONYEAR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_PEQUIFLOCUNION-CONSTRUCTIONYEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PEQUIFLOCUNION-CONSTRUCTIONYEAR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field CONSTRUCTIONMATERIAL CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_PEQUIFLOCUNION-CONSTRUCTIONMATERIAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PEQUIFLOCUNION-CONSTRUCTIONMATERIAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field GROSSWEIGHTUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PEQUIFLOCUNION-GROSSWEIGHTUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PEQUIFLOCUNION-GROSSWEIGHTUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATERIAL CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_PEQUIFLOCUNION-MATERIAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PEQUIFLOCUNION-MATERIAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GERNR, internal->external for field SERIALNUMBER CALL FUNCTION 'CONVERSION_EXIT_GERNR_OUTPUT' EXPORTING input = WA_PEQUIFLOCUNION-SERIALNUMBER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PEQUIFLOCUNION-SERIALNUMBER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TECHO, internal->external for field SUPERIORTECHNICALOBJECTLABEL CALL FUNCTION 'CONVERSION_EXIT_TECHO_OUTPUT' EXPORTING input = WA_PEQUIFLOCUNION-SUPERIORTECHNICALOBJECTLABEL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PEQUIFLOCUNION-SUPERIORTECHNICALOBJECTLABEL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field SUPERIORFUNCTIONALLOCATION CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_PEQUIFLOCUNION-SUPERIORFUNCTIONALLOCATION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PEQUIFLOCUNION-SUPERIORFUNCTIONALLOCATION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SUPERORDINATEEQUIPMENT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PEQUIFLOCUNION-SUPERORDINATEEQUIPMENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PEQUIFLOCUNION-SUPERORDINATEEQUIPMENT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PEQUIFLOCUNION_STR,
MANDT TYPE STRING,
TECHNICALOBJECT TYPE STRING,
TECHOBJISEQUIPORFUNCNLLOC TYPE STRING,
EQUIPMENT TYPE STRING,
FUNCTIONALLOCATION TYPE STRING,
TECHNICALOBJECTCATEGORY TYPE STRING,
TECHNICALOBJECTTYPE TYPE STRING,
CREATEDBYUSER TYPE STRING,
CREATIONDATE TYPE STRING,
LASTCHANGEDBYUSER TYPE STRING,
LASTCHANGEDATE TYPE STRING,
ASSETMANUFACTURERNAME TYPE STRING,
MANUFACTURERPARTTYPENAME TYPE STRING,
MAINTENANCEPLANNINGPLANT TYPE STRING,
MAINTENANCEPLANNERGROUP TYPE STRING,
CATALOGPROFILE TYPE STRING,
AUTHORIZATIONGROUP TYPE STRING,
WORKCENTERINTERNALID TYPE STRING,
WORKCENTERTYPECODE TYPE STRING,
MAINTOBJECTLOCACCTASSGMTNMBR TYPE STRING,
MANUFACTURERCOUNTRY TYPE STRING,
CONSTRUCTIONYEAR TYPE STRING,
CONSTRUCTIONMONTH TYPE STRING,
CONSTRUCTIONMATERIAL TYPE STRING,
ACQUISITIONDATE TYPE STRING,
CURRENCY TYPE STRING,
ACQUISITIONVALUE TYPE STRING,
MAINTOBJECTINTERNALID TYPE STRING,
TECHNICALOBJECTSORTCODE TYPE STRING,
MANUFACTURERPARTNMBR TYPE STRING,
SIZEORDIMENSIONTEXT TYPE STRING,
MANUFACTURERSERIALNUMBER TYPE STRING,
INVENTORYNUMBER TYPE STRING,
GROSSWEIGHT TYPE STRING,
GROSSWEIGHTUNIT TYPE STRING,
OPERATIONSTARTDATE TYPE STRING,
FUNCLOCSTRUCIDENTIFYINGLEVEL TYPE STRING,
FUNCLOCSTRUC2NDIDENTIFYINGLVL TYPE STRING,
FUNCLOCATIONSTRUCTURE TYPE STRING,
SALESORGANIZATION TYPE STRING,
DISTRIBUTIONCHANNEL TYPE STRING,
SALESOFFICE TYPE STRING,
ORGANIZATIONDIVISION TYPE STRING,
SALESGROUP TYPE STRING,
MATERIAL TYPE STRING,
SERIALNUMBER TYPE STRING,
TECHNICALOBJECTDESCRIPTION TYPE STRING,
TECHNICALOBJECTHASLONGTEXT TYPE STRING,
SUPERIORTECHNICALOBJECT TYPE STRING,
SUPERIORTECHNICALOBJECTLABEL TYPE STRING,
SUPERIORTECHNICALOBJECTNAME TYPE STRING,
SUPERIOROBJISEQUIPORFUNCNLLOC TYPE STRING,
SUPERIORFUNCTIONALLOCATION TYPE STRING,
SUPERORDINATEEQUIPMENT TYPE STRING,END OF T_EKKO_STR. DATA: WA_PEQUIFLOCUNION_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PEQUIFLOCUNION_STR-MANDT sy-vline
WA_PEQUIFLOCUNION_STR-TECHNICALOBJECT sy-vline
WA_PEQUIFLOCUNION_STR-TECHOBJISEQUIPORFUNCNLLOC sy-vline
WA_PEQUIFLOCUNION_STR-EQUIPMENT sy-vline
WA_PEQUIFLOCUNION_STR-FUNCTIONALLOCATION sy-vline
WA_PEQUIFLOCUNION_STR-TECHNICALOBJECTCATEGORY sy-vline
WA_PEQUIFLOCUNION_STR-TECHNICALOBJECTTYPE sy-vline
WA_PEQUIFLOCUNION_STR-CREATEDBYUSER sy-vline
WA_PEQUIFLOCUNION_STR-CREATIONDATE sy-vline
WA_PEQUIFLOCUNION_STR-LASTCHANGEDBYUSER sy-vline
WA_PEQUIFLOCUNION_STR-LASTCHANGEDATE sy-vline
WA_PEQUIFLOCUNION_STR-ASSETMANUFACTURERNAME sy-vline
WA_PEQUIFLOCUNION_STR-MANUFACTURERPARTTYPENAME sy-vline
WA_PEQUIFLOCUNION_STR-MAINTENANCEPLANNINGPLANT sy-vline
WA_PEQUIFLOCUNION_STR-MAINTENANCEPLANNERGROUP sy-vline
WA_PEQUIFLOCUNION_STR-CATALOGPROFILE sy-vline
WA_PEQUIFLOCUNION_STR-AUTHORIZATIONGROUP sy-vline
WA_PEQUIFLOCUNION_STR-WORKCENTERINTERNALID sy-vline
WA_PEQUIFLOCUNION_STR-WORKCENTERTYPECODE sy-vline
WA_PEQUIFLOCUNION_STR-MAINTOBJECTLOCACCTASSGMTNMBR sy-vline
WA_PEQUIFLOCUNION_STR-MANUFACTURERCOUNTRY sy-vline
WA_PEQUIFLOCUNION_STR-CONSTRUCTIONYEAR sy-vline
WA_PEQUIFLOCUNION_STR-CONSTRUCTIONMONTH sy-vline
WA_PEQUIFLOCUNION_STR-CONSTRUCTIONMATERIAL sy-vline
WA_PEQUIFLOCUNION_STR-ACQUISITIONDATE sy-vline
WA_PEQUIFLOCUNION_STR-CURRENCY sy-vline
WA_PEQUIFLOCUNION_STR-ACQUISITIONVALUE sy-vline
WA_PEQUIFLOCUNION_STR-MAINTOBJECTINTERNALID sy-vline
WA_PEQUIFLOCUNION_STR-TECHNICALOBJECTSORTCODE sy-vline
WA_PEQUIFLOCUNION_STR-MANUFACTURERPARTNMBR sy-vline
WA_PEQUIFLOCUNION_STR-SIZEORDIMENSIONTEXT sy-vline
WA_PEQUIFLOCUNION_STR-MANUFACTURERSERIALNUMBER sy-vline
WA_PEQUIFLOCUNION_STR-INVENTORYNUMBER sy-vline
WA_PEQUIFLOCUNION_STR-GROSSWEIGHT sy-vline
WA_PEQUIFLOCUNION_STR-GROSSWEIGHTUNIT sy-vline
WA_PEQUIFLOCUNION_STR-OPERATIONSTARTDATE sy-vline
WA_PEQUIFLOCUNION_STR-FUNCLOCSTRUCIDENTIFYINGLEVEL sy-vline
WA_PEQUIFLOCUNION_STR-FUNCLOCSTRUC2NDIDENTIFYINGLVL sy-vline
WA_PEQUIFLOCUNION_STR-FUNCLOCATIONSTRUCTURE sy-vline
WA_PEQUIFLOCUNION_STR-SALESORGANIZATION sy-vline
WA_PEQUIFLOCUNION_STR-DISTRIBUTIONCHANNEL sy-vline
WA_PEQUIFLOCUNION_STR-SALESOFFICE sy-vline
WA_PEQUIFLOCUNION_STR-ORGANIZATIONDIVISION sy-vline
WA_PEQUIFLOCUNION_STR-SALESGROUP sy-vline
WA_PEQUIFLOCUNION_STR-MATERIAL sy-vline
WA_PEQUIFLOCUNION_STR-SERIALNUMBER sy-vline
WA_PEQUIFLOCUNION_STR-TECHNICALOBJECTDESCRIPTION sy-vline
WA_PEQUIFLOCUNION_STR-TECHNICALOBJECTHASLONGTEXT sy-vline
WA_PEQUIFLOCUNION_STR-SUPERIORTECHNICALOBJECT sy-vline
WA_PEQUIFLOCUNION_STR-SUPERIORTECHNICALOBJECTLABEL sy-vline
WA_PEQUIFLOCUNION_STR-SUPERIORTECHNICALOBJECTNAME sy-vline
WA_PEQUIFLOCUNION_STR-SUPERIOROBJISEQUIPORFUNCNLLOC sy-vline
WA_PEQUIFLOCUNION_STR-SUPERIORFUNCTIONALLOCATION sy-vline
WA_PEQUIFLOCUNION_STR-SUPERORDINATEEQUIPMENT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.