ABAP Select data from SAP table PDSMAINT_COMP_STR into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PDSMAINT_COMP_STR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PDSMAINT_COMP_STR. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PDSMAINT_COMP_STR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PDSMAINT_COMP_STR TYPE STANDARD TABLE OF PDSMAINT_COMP_STR,
      WA_PDSMAINT_COMP_STR TYPE PDSMAINT_COMP_STR,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PDSMAINT_COMP_STR> TYPE PDSMAINT_COMP_STR.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PDSMAINT_COMP_STR.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PDSMAINT_COMP_STR
  INTO TABLE IT_PDSMAINT_COMP_STR.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PDSMAINT_COMP_STR
*  INTO TABLE @DATA(IT_PDSMAINT_COMP_STR2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PDSMAINT_COMP_STR INDEX 1 INTO DATA(WA_PDSMAINT_COMP_STR2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PDSMAINT_COMP_STR ASSIGNING <PDSMAINT_COMP_STR>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PDSMAINT_COMP_STR>-MANDT = 1.
<PDSMAINT_COMP_STR>-GUID = 1.
<PDSMAINT_COMP_STR>-GUID_COMP = 1.
<PDSMAINT_COMP_STR>-WERKS = 1.
<PDSMAINT_COMP_STR>-MATNR = 1.
ENDLOOP.

LOOP AT IT_PDSMAINT_COMP_STR INTO WA_PDSMAINT_COMP_STR.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PDSMAINT_COMP_STR-STLTY, sy-vline,
WA_PDSMAINT_COMP_STR-STLNR, sy-vline,
WA_PDSMAINT_COMP_STR-ELIFN, sy-vline,
WA_PDSMAINT_COMP_STR-STLAL, sy-vline,
WA_PDSMAINT_COMP_STR-STLAN, sy-vline,
WA_PDSMAINT_COMP_STR-STVKN, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PDSMAINT_COMP_STR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PDSMAINT_COMP_STR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PDSMAINT_COMP_STR INTO WA_PDSMAINT_COMP_STR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_PDSMAINT_COMP_STR-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PDSMAINT_COMP_STR-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field STLNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_PDSMAINT_COMP_STR-STLNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PDSMAINT_COMP_STR-STLNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ELIFN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PDSMAINT_COMP_STR-ELIFN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PDSMAINT_COMP_STR-ELIFN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field STLAL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PDSMAINT_COMP_STR-STLAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PDSMAINT_COMP_STR-STLAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field POSNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_PDSMAINT_COMP_STR-POSNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PDSMAINT_COMP_STR-POSNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PDSMAINT_COMP_STR_STR,
MANDT TYPE STRING,
GUID TYPE STRING,
GUID_COMP TYPE STRING,
WERKS TYPE STRING,
MATNR TYPE STRING,
STLTY TYPE STRING,
STLNR TYPE STRING,
ELIFN TYPE STRING,
STLAL TYPE STRING,
STLAN TYPE STRING,
STVKN TYPE STRING,
STPOZ TYPE STRING,
POSTP TYPE STRING,
POSNR TYPE STRING,
CONS_TYPE TYPE STRING,
SCM_CLASS TYPE STRING,
CREATE_USER TYPE STRING,
CREATE_TIME TYPE STRING,
CHANGE_USER TYPE STRING,
CHANGE_TIME TYPE STRING,END OF T_EKKO_STR. DATA: WA_PDSMAINT_COMP_STR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PDSMAINT_COMP_STR_STR-MANDT sy-vline
WA_PDSMAINT_COMP_STR_STR-GUID sy-vline
WA_PDSMAINT_COMP_STR_STR-GUID_COMP sy-vline
WA_PDSMAINT_COMP_STR_STR-WERKS sy-vline
WA_PDSMAINT_COMP_STR_STR-MATNR sy-vline
WA_PDSMAINT_COMP_STR_STR-STLTY sy-vline
WA_PDSMAINT_COMP_STR_STR-STLNR sy-vline
WA_PDSMAINT_COMP_STR_STR-ELIFN sy-vline
WA_PDSMAINT_COMP_STR_STR-STLAL sy-vline
WA_PDSMAINT_COMP_STR_STR-STLAN sy-vline
WA_PDSMAINT_COMP_STR_STR-STVKN sy-vline
WA_PDSMAINT_COMP_STR_STR-STPOZ sy-vline
WA_PDSMAINT_COMP_STR_STR-POSTP sy-vline
WA_PDSMAINT_COMP_STR_STR-POSNR sy-vline
WA_PDSMAINT_COMP_STR_STR-CONS_TYPE sy-vline
WA_PDSMAINT_COMP_STR_STR-SCM_CLASS sy-vline
WA_PDSMAINT_COMP_STR_STR-CREATE_USER sy-vline
WA_PDSMAINT_COMP_STR_STR-CREATE_TIME sy-vline
WA_PDSMAINT_COMP_STR_STR-CHANGE_USER sy-vline
WA_PDSMAINT_COMP_STR_STR-CHANGE_TIME sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.