ABAP Select data from SAP table PDA01 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PDA01 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PDA01. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PDA01 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PDA01 TYPE STANDARD TABLE OF PDA01,
      WA_PDA01 TYPE PDA01,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PDA01> TYPE PDA01.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PDA01.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PDA01
  INTO TABLE IT_PDA01.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PDA01
*  INTO TABLE @DATA(IT_PDA012).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PDA01 INDEX 1 INTO DATA(WA_PDA012).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PDA01 ASSIGNING <PDA01>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PDA01>-PERNR = 1.
<PDA01>-AUFNR = 1.
<PDA01>-APLFL = 1.
<PDA01>-VORNR = 1.
<PDA01>-UVORN = 1.
ENDLOOP.

LOOP AT IT_PDA01 INTO WA_PDA01.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PDA01-LDATE, sy-vline,
WA_PDA01-LTIME, sy-vline,
WA_PDA01-RUECK, sy-vline,
WA_PDA01-SATZA, sy-vline,
WA_PDA01-WERKS, sy-vline,
WA_PDA01-ARBID, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PDA01 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PDA01 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PDA01 INTO WA_PDA01. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field AUFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PDA01-AUFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PDA01-AUFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field APLFL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PDA01-APLFL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PDA01-APLFL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field VORNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_PDA01-VORNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PDA01-VORNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field UVORN CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_PDA01-UVORN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PDA01-UVORN.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PDA01_STR,
PERNR TYPE STRING,
AUFNR TYPE STRING,
APLFL TYPE STRING,
VORNR TYPE STRING,
UVORN TYPE STRING,
LDATE TYPE STRING,
LTIME TYPE STRING,
RUECK TYPE STRING,
SATZA TYPE STRING,
WERKS TYPE STRING,
ARBID TYPE STRING,
KAPAR TYPE STRING,
SPLIT TYPE STRING,
PDSNR TYPE STRING,
STOKZ TYPE STRING,END OF T_EKKO_STR. DATA: WA_PDA01_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PDA01_STR-PERNR sy-vline
WA_PDA01_STR-AUFNR sy-vline
WA_PDA01_STR-APLFL sy-vline
WA_PDA01_STR-VORNR sy-vline
WA_PDA01_STR-UVORN sy-vline
WA_PDA01_STR-LDATE sy-vline
WA_PDA01_STR-LTIME sy-vline
WA_PDA01_STR-RUECK sy-vline
WA_PDA01_STR-SATZA sy-vline
WA_PDA01_STR-WERKS sy-vline
WA_PDA01_STR-ARBID sy-vline
WA_PDA01_STR-KAPAR sy-vline
WA_PDA01_STR-SPLIT sy-vline
WA_PDA01_STR-PDSNR sy-vline
WA_PDA01_STR-STOKZ sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.