ABAP Select data from SAP table PCZ_TU_CERT_S into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PCZ_TU_CERT_S table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PCZ_TU_CERT_S. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PCZ_TU_CERT_S table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PCZ_TU_CERT_S TYPE STANDARD TABLE OF PCZ_TU_CERT_S,
      WA_PCZ_TU_CERT_S TYPE PCZ_TU_CERT_S,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PCZ_TU_CERT_S> TYPE PCZ_TU_CERT_S.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PCZ_TU_CERT_S.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PCZ_TU_CERT_S
  INTO TABLE IT_PCZ_TU_CERT_S.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PCZ_TU_CERT_S
*  INTO TABLE @DATA(IT_PCZ_TU_CERT_S2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PCZ_TU_CERT_S INDEX 1 INTO DATA(WA_PCZ_TU_CERT_S2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PCZ_TU_CERT_S ASSIGNING <PCZ_TU_CERT_S>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PCZ_TU_CERT_S>-PERNR = 1.
<PCZ_TU_CERT_S>-PERID = 1.
<PCZ_TU_CERT_S>-PSTLZ = 1.
<PCZ_TU_CERT_S>-JMENO_DAR = 1.
<PCZ_TU_CERT_S>-ADRESA_DAR = 1.
ENDLOOP.

LOOP AT IT_PCZ_TU_CERT_S INTO WA_PCZ_TU_CERT_S.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PCZ_TU_CERT_S-JMENO_ZAM, sy-vline,
WA_PCZ_TU_CERT_S-ADRESA_ZAM, sy-vline,
WA_PCZ_TU_CERT_S-ROK, sy-vline,
WA_PCZ_TU_CERT_S-DATZUCT, sy-vline,
WA_PCZ_TU_CERT_S-VYHOTOVIL, sy-vline,
WA_PCZ_TU_CERT_S-P_TEL, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PCZ_TU_CERT_S you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PCZ_TU_CERT_S TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PCZ_TU_CERT_S INTO WA_PCZ_TU_CERT_S. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PCZ_TU_CERT_S_STR,
PERNR TYPE STRING,
PERID TYPE STRING,
PSTLZ TYPE STRING,
JMENO_DAR TYPE STRING,
ADRESA_DAR TYPE STRING,
JMENO_ZAM TYPE STRING,
ADRESA_ZAM TYPE STRING,
ROK TYPE STRING,
DATZUCT TYPE STRING,
VYHOTOVIL TYPE STRING,
P_TEL TYPE STRING,
PRISPEVEK TYPE STRING,
ODBID TYPE STRING,
STAMP TYPE STRING,END OF T_EKKO_STR. DATA: WA_PCZ_TU_CERT_S_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PCZ_TU_CERT_S_STR-PERNR sy-vline
WA_PCZ_TU_CERT_S_STR-PERID sy-vline
WA_PCZ_TU_CERT_S_STR-PSTLZ sy-vline
WA_PCZ_TU_CERT_S_STR-JMENO_DAR sy-vline
WA_PCZ_TU_CERT_S_STR-ADRESA_DAR sy-vline
WA_PCZ_TU_CERT_S_STR-JMENO_ZAM sy-vline
WA_PCZ_TU_CERT_S_STR-ADRESA_ZAM sy-vline
WA_PCZ_TU_CERT_S_STR-ROK sy-vline
WA_PCZ_TU_CERT_S_STR-DATZUCT sy-vline
WA_PCZ_TU_CERT_S_STR-VYHOTOVIL sy-vline
WA_PCZ_TU_CERT_S_STR-P_TEL sy-vline
WA_PCZ_TU_CERT_S_STR-PRISPEVEK sy-vline
WA_PCZ_TU_CERT_S_STR-ODBID sy-vline
WA_PCZ_TU_CERT_S_STR-STAMP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.