ABAP Select data from SAP table PCZ_IV0011 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PCZ_IV0011 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PCZ_IV0011. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PCZ_IV0011 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PCZ_IV0011 TYPE STANDARD TABLE OF PCZ_IV0011,
      WA_PCZ_IV0011 TYPE PCZ_IV0011,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PCZ_IV0011> TYPE PCZ_IV0011.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PCZ_IV0011.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PCZ_IV0011
  INTO TABLE IT_PCZ_IV0011.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PCZ_IV0011
*  INTO TABLE @DATA(IT_PCZ_IV00112).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PCZ_IV0011 INDEX 1 INTO DATA(WA_PCZ_IV00112).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PCZ_IV0011 ASSIGNING <PCZ_IV0011>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PCZ_IV0011>-PERNR = 1.
<PCZ_IV0011>-INFTY = 1.
<PCZ_IV0011>-SUBTY = 1.
<PCZ_IV0011>-OBJPS = 1.
<PCZ_IV0011>-SPRPS = 1.
ENDLOOP.

LOOP AT IT_PCZ_IV0011 INTO WA_PCZ_IV0011.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PCZ_IV0011-ENDDA, sy-vline,
WA_PCZ_IV0011-BEGDA, sy-vline,
WA_PCZ_IV0011-SEQNR, sy-vline,
WA_PCZ_IV0011-AEDTM, sy-vline,
WA_PCZ_IV0011-UNAME, sy-vline,
WA_PCZ_IV0011-HISTO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PCZ_IV0011 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PCZ_IV0011 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PCZ_IV0011 INTO WA_PCZ_IV0011. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field ESRRE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PCZ_IV0011-ESRRE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PCZ_IV0011-ESRRE.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PCZ_IV0011_STR,
PERNR TYPE STRING,
INFTY TYPE STRING,
SUBTY TYPE STRING,
OBJPS TYPE STRING,
SPRPS TYPE STRING,
ENDDA TYPE STRING,
BEGDA TYPE STRING,
SEQNR TYPE STRING,
AEDTM TYPE STRING,
UNAME TYPE STRING,
HISTO TYPE STRING,
ITXEX TYPE STRING,
REFEX TYPE STRING,
ORDEX TYPE STRING,
ITBLD TYPE STRING,
PREAS TYPE STRING,
FLAG1 TYPE STRING,
FLAG2 TYPE STRING,
FLAG3 TYPE STRING,
FLAG4 TYPE STRING,
RESE1 TYPE STRING,
RESE2 TYPE STRING,
GRPVL TYPE STRING,
LGART TYPE STRING,
OPKEN TYPE STRING,
BETRG TYPE STRING,
WAERS TYPE STRING,
ANZHL TYPE STRING,
ZEINH TYPE STRING,
ZDATE TYPE STRING,
ZFPER TYPE STRING,
ZANZL TYPE STRING,
ZEINZ TYPE STRING,
PRITY TYPE STRING,
EMFSL TYPE STRING,
EMFTX TYPE STRING,
BKPLZ TYPE STRING,
BKORT TYPE STRING,
BANKS TYPE STRING,
BANKL TYPE STRING,
BANKN TYPE STRING,
BANKP TYPE STRING,
BKONT TYPE STRING,
SWIFT TYPE STRING,
DTAWS TYPE STRING,
DTAMS TYPE STRING,
STCD1 TYPE STRING,
STCD2 TYPE STRING,
PSKTO TYPE STRING,
ESRNR TYPE STRING,
ESRRE TYPE STRING,
ESRPZ TYPE STRING,
ZWECK TYPE STRING,
ZLSCH TYPE STRING,
UWDAT TYPE STRING,
BKREF TYPE STRING,
STRAS TYPE STRING,
STATE TYPE STRING,
IBAN TYPE STRING,
DZDATE TYPE STRING,
CEXIN TYPE STRING,
ORDNR TYPE STRING,
DEDUP TYPE STRING,
NORND TYPE STRING,
DEPOS TYPE STRING,
WODPP TYPE STRING,
AUTCM TYPE STRING,
TXBON TYPE STRING,
HLPST TYPE STRING,
VDBRZ TYPE STRING,
VPRZD TYPE STRING,
PZRZD TYPE STRING,
DDLVY TYPE STRING,
GAAUX TYPE STRING,
GSTOP TYPE STRING,END OF T_EKKO_STR. DATA: WA_PCZ_IV0011_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PCZ_IV0011_STR-PERNR sy-vline
WA_PCZ_IV0011_STR-INFTY sy-vline
WA_PCZ_IV0011_STR-SUBTY sy-vline
WA_PCZ_IV0011_STR-OBJPS sy-vline
WA_PCZ_IV0011_STR-SPRPS sy-vline
WA_PCZ_IV0011_STR-ENDDA sy-vline
WA_PCZ_IV0011_STR-BEGDA sy-vline
WA_PCZ_IV0011_STR-SEQNR sy-vline
WA_PCZ_IV0011_STR-AEDTM sy-vline
WA_PCZ_IV0011_STR-UNAME sy-vline
WA_PCZ_IV0011_STR-HISTO sy-vline
WA_PCZ_IV0011_STR-ITXEX sy-vline
WA_PCZ_IV0011_STR-REFEX sy-vline
WA_PCZ_IV0011_STR-ORDEX sy-vline
WA_PCZ_IV0011_STR-ITBLD sy-vline
WA_PCZ_IV0011_STR-PREAS sy-vline
WA_PCZ_IV0011_STR-FLAG1 sy-vline
WA_PCZ_IV0011_STR-FLAG2 sy-vline
WA_PCZ_IV0011_STR-FLAG3 sy-vline
WA_PCZ_IV0011_STR-FLAG4 sy-vline
WA_PCZ_IV0011_STR-RESE1 sy-vline
WA_PCZ_IV0011_STR-RESE2 sy-vline
WA_PCZ_IV0011_STR-GRPVL sy-vline
WA_PCZ_IV0011_STR-LGART sy-vline
WA_PCZ_IV0011_STR-OPKEN sy-vline
WA_PCZ_IV0011_STR-BETRG sy-vline
WA_PCZ_IV0011_STR-WAERS sy-vline
WA_PCZ_IV0011_STR-ANZHL sy-vline
WA_PCZ_IV0011_STR-ZEINH sy-vline
WA_PCZ_IV0011_STR-ZDATE sy-vline
WA_PCZ_IV0011_STR-ZFPER sy-vline
WA_PCZ_IV0011_STR-ZANZL sy-vline
WA_PCZ_IV0011_STR-ZEINZ sy-vline
WA_PCZ_IV0011_STR-PRITY sy-vline
WA_PCZ_IV0011_STR-EMFSL sy-vline
WA_PCZ_IV0011_STR-EMFTX sy-vline
WA_PCZ_IV0011_STR-BKPLZ sy-vline
WA_PCZ_IV0011_STR-BKORT sy-vline
WA_PCZ_IV0011_STR-BANKS sy-vline
WA_PCZ_IV0011_STR-BANKL sy-vline
WA_PCZ_IV0011_STR-BANKN sy-vline
WA_PCZ_IV0011_STR-BANKP sy-vline
WA_PCZ_IV0011_STR-BKONT sy-vline
WA_PCZ_IV0011_STR-SWIFT sy-vline
WA_PCZ_IV0011_STR-DTAWS sy-vline
WA_PCZ_IV0011_STR-DTAMS sy-vline
WA_PCZ_IV0011_STR-STCD1 sy-vline
WA_PCZ_IV0011_STR-STCD2 sy-vline
WA_PCZ_IV0011_STR-PSKTO sy-vline
WA_PCZ_IV0011_STR-ESRNR sy-vline
WA_PCZ_IV0011_STR-ESRRE sy-vline
WA_PCZ_IV0011_STR-ESRPZ sy-vline
WA_PCZ_IV0011_STR-ZWECK sy-vline
WA_PCZ_IV0011_STR-ZLSCH sy-vline
WA_PCZ_IV0011_STR-UWDAT sy-vline
WA_PCZ_IV0011_STR-BKREF sy-vline
WA_PCZ_IV0011_STR-STRAS sy-vline
WA_PCZ_IV0011_STR-STATE sy-vline
WA_PCZ_IV0011_STR-IBAN sy-vline
WA_PCZ_IV0011_STR-DZDATE sy-vline
WA_PCZ_IV0011_STR-CEXIN sy-vline
WA_PCZ_IV0011_STR-ORDNR sy-vline
WA_PCZ_IV0011_STR-DEDUP sy-vline
WA_PCZ_IV0011_STR-NORND sy-vline
WA_PCZ_IV0011_STR-DEPOS sy-vline
WA_PCZ_IV0011_STR-WODPP sy-vline
WA_PCZ_IV0011_STR-AUTCM sy-vline
WA_PCZ_IV0011_STR-TXBON sy-vline
WA_PCZ_IV0011_STR-HLPST sy-vline
WA_PCZ_IV0011_STR-VDBRZ sy-vline
WA_PCZ_IV0011_STR-VPRZD sy-vline
WA_PCZ_IV0011_STR-PZRZD sy-vline
WA_PCZ_IV0011_STR-DDLVY sy-vline
WA_PCZ_IV0011_STR-GAAUX sy-vline
WA_PCZ_IV0011_STR-GSTOP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.