ABAP Select data from SAP table PCNTC into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PCNTC table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PCNTC. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PCNTC table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PCNTC TYPE STANDARD TABLE OF PCNTC,
      WA_PCNTC TYPE PCNTC,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PCNTC> TYPE PCNTC.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PCNTC.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PCNTC
  INTO TABLE IT_PCNTC.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PCNTC
*  INTO TABLE @DATA(IT_PCNTC2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PCNTC INDEX 1 INTO DATA(WA_PCNTC2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PCNTC ASSIGNING <PCNTC>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PCNTC>-TXARE = 1.
<PCNTC>-WERKS = 1.
<PCNTC>-BTRTL = 1.
<PCNTC>-PERSG = 1.
<PCNTC>-PERSK = 1.
ENDLOOP.

LOOP AT IT_PCNTC INTO WA_PCNTC.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PCNTC-ABKRS, sy-vline,
WA_PCNTC-ORGEH, sy-vline,
WA_PCNTC-TRFAR, sy-vline,
WA_PCNTC-TRFGB, sy-vline,
WA_PCNTC-TRFGR, sy-vline,
WA_PCNTC-TRFST, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PCNTC you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PCNTC TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PCNTC INTO WA_PCNTC. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PCNTC_STR,
TXARE TYPE STRING,
WERKS TYPE STRING,
BTRTL TYPE STRING,
PERSG TYPE STRING,
PERSK TYPE STRING,
ABKRS TYPE STRING,
ORGEH TYPE STRING,
TRFAR TYPE STRING,
TRFGB TYPE STRING,
TRFGR TYPE STRING,
TRFST TYPE STRING,
INCAT TYPE STRING,
RLCAT TYPE STRING,END OF T_EKKO_STR. DATA: WA_PCNTC_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PCNTC_STR-TXARE sy-vline
WA_PCNTC_STR-WERKS sy-vline
WA_PCNTC_STR-BTRTL sy-vline
WA_PCNTC_STR-PERSG sy-vline
WA_PCNTC_STR-PERSK sy-vline
WA_PCNTC_STR-ABKRS sy-vline
WA_PCNTC_STR-ORGEH sy-vline
WA_PCNTC_STR-TRFAR sy-vline
WA_PCNTC_STR-TRFGB sy-vline
WA_PCNTC_STR-TRFGR sy-vline
WA_PCNTC_STR-TRFST sy-vline
WA_PCNTC_STR-INCAT sy-vline
WA_PCNTC_STR-RLCAT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.