ABAP Select data from SAP table PCCUPLDMD into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP PCCUPLDMD table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PCCUPLDMD. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the PCCUPLDMD table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_PCCUPLDMD TYPE STANDARD TABLE OF PCCUPLDMD, WA_PCCUPLDMD TYPE PCCUPLDMD, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <PCCUPLDMD> TYPE PCCUPLDMD. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_PCCUPLDMD. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM PCCUPLDMD INTO TABLE IT_PCCUPLDMD. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM PCCUPLDMD * INTO TABLE @DATA(IT_PCCUPLDMD2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_PCCUPLDMD INDEX 1 INTO DATA(WA_PCCUPLDMD2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_PCCUPLDMD ASSIGNING <PCCUPLDMD>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<PCCUPLDMD>-MANDT = 1.
<PCCUPLDMD>-UUID = 1.
<PCCUPLDMD>-MD_TYPE = 1.
<PCCUPLDMD>-ADDITIONALMASTERDATACODE = 1.
<PCCUPLDMD>-ADDITIONALMDSUPRORDFIELDVALUE = 1.
ENDLOOP. LOOP AT IT_PCCUPLDMD INTO WA_PCCUPLDMD. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_PCCUPLDMD-ADDITIONALMASTERDATATEXT, sy-vline,
WA_PCCUPLDMD-MD_TYPE_DESCRIPTION, sy-vline,
WA_PCCUPLDMD-STATUS, sy-vline,
WA_PCCUPLDMD-STATUS_TEXT, sy-vline,
WA_PCCUPLDMD-CHECK_RESULT, sy-vline,
WA_PCCUPLDMD-EXTNUMBER, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PCCUPLDMD you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PCCUPLDMD TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PCCUPLDMD INTO WA_PCCUPLDMD. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PCCUPLDMD_STR,
MANDT TYPE STRING,
UUID TYPE STRING,
MD_TYPE TYPE STRING,
ADDITIONALMASTERDATACODE TYPE STRING,
ADDITIONALMDSUPRORDFIELDVALUE TYPE STRING,
ADDITIONALMASTERDATATEXT TYPE STRING,
MD_TYPE_DESCRIPTION TYPE STRING,
STATUS TYPE STRING,
STATUS_TEXT TYPE STRING,
CHECK_RESULT TYPE STRING,
EXTNUMBER TYPE STRING,
LOGNUMBER TYPE STRING,END OF T_EKKO_STR. DATA: WA_PCCUPLDMD_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PCCUPLDMD_STR-MANDT sy-vline
WA_PCCUPLDMD_STR-UUID sy-vline
WA_PCCUPLDMD_STR-MD_TYPE sy-vline
WA_PCCUPLDMD_STR-ADDITIONALMASTERDATACODE sy-vline
WA_PCCUPLDMD_STR-ADDITIONALMDSUPRORDFIELDVALUE sy-vline
WA_PCCUPLDMD_STR-ADDITIONALMASTERDATATEXT sy-vline
WA_PCCUPLDMD_STR-MD_TYPE_DESCRIPTION sy-vline
WA_PCCUPLDMD_STR-STATUS sy-vline
WA_PCCUPLDMD_STR-STATUS_TEXT sy-vline
WA_PCCUPLDMD_STR-CHECK_RESULT sy-vline
WA_PCCUPLDMD_STR-EXTNUMBER sy-vline
WA_PCCUPLDMD_STR-LOGNUMBER sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.