ABAP Select data from SAP table PCCCCONST into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PCCCCONST table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PCCCCONST. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PCCCCONST table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PCCCCONST TYPE STANDARD TABLE OF PCCCCONST,
      WA_PCCCCONST TYPE PCCCCONST,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PCCCCONST> TYPE PCCCCONST.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PCCCCONST.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PCCCCONST
  INTO TABLE IT_PCCCCONST.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PCCCCONST
*  INTO TABLE @DATA(IT_PCCCCONST2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PCCCCONST INDEX 1 INTO DATA(WA_PCCCCONST2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PCCCCONST ASSIGNING <PCCCCONST>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PCCCCONST>-DUMMY = 1.
<PCCCCONST>-CONSTANT0 = 1.
<PCCCCONST>-CONSTANT1 = 1.
<PCCCCONST>-CONSTANT2 = 1.
<PCCCCONST>-CONSTANT3 = 1.
ENDLOOP.

LOOP AT IT_PCCCCONST INTO WA_PCCCCONST.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PCCCCONST-CONSTANT4, sy-vline,
WA_PCCCCONST-CONSTANTEMPTYRAW16, sy-vline,
WA_PCCCCONST-CONSTANTHYPHEN, sy-vline,
WA_PCCCCONST-CONSTANTRAW, sy-vline,
WA_PCCCCONST-CONSTANTEMPTY, sy-vline,
WA_PCCCCONST-CONSTANTTRUE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PCCCCONST you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PCCCCONST TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PCCCCONST INTO WA_PCCCCONST. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PCCCCONST_STR,
DUMMY TYPE STRING,
CONSTANT0 TYPE STRING,
CONSTANT1 TYPE STRING,
CONSTANT2 TYPE STRING,
CONSTANT3 TYPE STRING,
CONSTANT4 TYPE STRING,
CONSTANTEMPTYRAW16 TYPE STRING,
CONSTANTHYPHEN TYPE STRING,
CONSTANTRAW TYPE STRING,
CONSTANTEMPTY TYPE STRING,
CONSTANTTRUE TYPE STRING,
CONSTANTFALSE TYPE STRING,
CONSTANTNOTEXISTING TYPE STRING,
CONSTANTMIXTURE TYPE STRING,
CONSTANTINPROGRESS TYPE STRING,
CONSTANTINITIALVERSION TYPE STRING,
CONSTANTRELEASED TYPE STRING,
CONSTANTCALCULATED TYPE STRING,
CONSTANTOUTDATED TYPE STRING,
CONSTANTMISSING TYPE STRING,
CONSTANTCOMPSTATFORRELEASE TYPE STRING,
CONSTANTCOMPSTATNEW TYPE STRING,
CONSTANT01 TYPE STRING,
CONSTANT02 TYPE STRING,
CONSTANT03 TYPE STRING,
CONSTANT04 TYPE STRING,
CONSTANTNEW TYPE STRING,
CONSTANTACTIVE TYPE STRING,
CONSTANTUPDATED TYPE STRING,
CONSTANTNONE TYPE STRING,
CONSTANTCOMPLETE TYPE STRING,
CONSTANTINPROCESS TYPE STRING,
CONSTANTCCI TYPE STRING,
CONSTANTSUB TYPE STRING,
CONSTANTCSM TYPE STRING,
CONSTANTCCMPS TYPE STRING,
CONSTANTCRR TYPE STRING,
CONSTANTCR TYPE STRING,
CONSTANTCRV TYPE STRING,
CONSTANTPRP TYPE STRING,
CONSTANTPCSRQ TYPE STRING,
CONSTANTEVTSTSNEW TYPE STRING,
CONSTANTEVTSTSINPROGRESS TYPE STRING,
CONSTANTEVTSTSFATAL TYPE STRING,
CONSTANTEVTSTSERROR TYPE STRING,
CONSTANTEVTSTSCOMPLETED TYPE STRING,
CONSTANTCHGSTSNEWCOMP TYPE STRING,
CONSTANTCHGSTSREMOVDCOMP TYPE STRING,
CONSTANTCHGSTSNEWSUB TYPE STRING,
CONSTANTCHGSTSREMOVDSUB TYPE STRING,
CONSTANTCHGSTSDIFFCONC TYPE STRING,
CONSTANTCHGSTSDIFFROLE TYPE STRING,
CONSTANTLGLDVNCATREPLACED TYPE STRING,
CONSTANTLGLDVNCATUNCHANGED TYPE STRING,
CONSTANTRAWMATERIALSEMOBJ TYPE STRING,
CONSTANTUNPACKAGEDPRODSEMOBJ TYPE STRING,END OF T_EKKO_STR. DATA: WA_PCCCCONST_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PCCCCONST_STR-DUMMY sy-vline
WA_PCCCCONST_STR-CONSTANT0 sy-vline
WA_PCCCCONST_STR-CONSTANT1 sy-vline
WA_PCCCCONST_STR-CONSTANT2 sy-vline
WA_PCCCCONST_STR-CONSTANT3 sy-vline
WA_PCCCCONST_STR-CONSTANT4 sy-vline
WA_PCCCCONST_STR-CONSTANTEMPTYRAW16 sy-vline
WA_PCCCCONST_STR-CONSTANTHYPHEN sy-vline
WA_PCCCCONST_STR-CONSTANTRAW sy-vline
WA_PCCCCONST_STR-CONSTANTEMPTY sy-vline
WA_PCCCCONST_STR-CONSTANTTRUE sy-vline
WA_PCCCCONST_STR-CONSTANTFALSE sy-vline
WA_PCCCCONST_STR-CONSTANTNOTEXISTING sy-vline
WA_PCCCCONST_STR-CONSTANTMIXTURE sy-vline
WA_PCCCCONST_STR-CONSTANTINPROGRESS sy-vline
WA_PCCCCONST_STR-CONSTANTINITIALVERSION sy-vline
WA_PCCCCONST_STR-CONSTANTRELEASED sy-vline
WA_PCCCCONST_STR-CONSTANTCALCULATED sy-vline
WA_PCCCCONST_STR-CONSTANTOUTDATED sy-vline
WA_PCCCCONST_STR-CONSTANTMISSING sy-vline
WA_PCCCCONST_STR-CONSTANTCOMPSTATFORRELEASE sy-vline
WA_PCCCCONST_STR-CONSTANTCOMPSTATNEW sy-vline
WA_PCCCCONST_STR-CONSTANT01 sy-vline
WA_PCCCCONST_STR-CONSTANT02 sy-vline
WA_PCCCCONST_STR-CONSTANT03 sy-vline
WA_PCCCCONST_STR-CONSTANT04 sy-vline
WA_PCCCCONST_STR-CONSTANTNEW sy-vline
WA_PCCCCONST_STR-CONSTANTACTIVE sy-vline
WA_PCCCCONST_STR-CONSTANTUPDATED sy-vline
WA_PCCCCONST_STR-CONSTANTNONE sy-vline
WA_PCCCCONST_STR-CONSTANTCOMPLETE sy-vline
WA_PCCCCONST_STR-CONSTANTINPROCESS sy-vline
WA_PCCCCONST_STR-CONSTANTCCI sy-vline
WA_PCCCCONST_STR-CONSTANTSUB sy-vline
WA_PCCCCONST_STR-CONSTANTCSM sy-vline
WA_PCCCCONST_STR-CONSTANTCCMPS sy-vline
WA_PCCCCONST_STR-CONSTANTCRR sy-vline
WA_PCCCCONST_STR-CONSTANTCR sy-vline
WA_PCCCCONST_STR-CONSTANTCRV sy-vline
WA_PCCCCONST_STR-CONSTANTPRP sy-vline
WA_PCCCCONST_STR-CONSTANTPCSRQ sy-vline
WA_PCCCCONST_STR-CONSTANTEVTSTSNEW sy-vline
WA_PCCCCONST_STR-CONSTANTEVTSTSINPROGRESS sy-vline
WA_PCCCCONST_STR-CONSTANTEVTSTSFATAL sy-vline
WA_PCCCCONST_STR-CONSTANTEVTSTSERROR sy-vline
WA_PCCCCONST_STR-CONSTANTEVTSTSCOMPLETED sy-vline
WA_PCCCCONST_STR-CONSTANTCHGSTSNEWCOMP sy-vline
WA_PCCCCONST_STR-CONSTANTCHGSTSREMOVDCOMP sy-vline
WA_PCCCCONST_STR-CONSTANTCHGSTSNEWSUB sy-vline
WA_PCCCCONST_STR-CONSTANTCHGSTSREMOVDSUB sy-vline
WA_PCCCCONST_STR-CONSTANTCHGSTSDIFFCONC sy-vline
WA_PCCCCONST_STR-CONSTANTCHGSTSDIFFROLE sy-vline
WA_PCCCCONST_STR-CONSTANTLGLDVNCATREPLACED sy-vline
WA_PCCCCONST_STR-CONSTANTLGLDVNCATUNCHANGED sy-vline
WA_PCCCCONST_STR-CONSTANTRAWMATERIALSEMOBJ sy-vline
WA_PCCCCONST_STR-CONSTANTUNPACKAGEDPRODSEMOBJ sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.