ABAP Select data from SAP table PC2UCLM into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PC2UCLM table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PC2UCLM. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PC2UCLM table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PC2UCLM TYPE STANDARD TABLE OF PC2UCLM,
      WA_PC2UCLM TYPE PC2UCLM,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PC2UCLM> TYPE PC2UCLM.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PC2UCLM.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PC2UCLM
  INTO TABLE IT_PC2UCLM.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PC2UCLM
*  INTO TABLE @DATA(IT_PC2UCLM2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PC2UCLM INDEX 1 INTO DATA(WA_PC2UCLM2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PC2UCLM ASSIGNING <PC2UCLM>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PC2UCLM>-SEQNO = 1.
<PC2UCLM>-LGART = 1.
<PC2UCLM>-FPPER = 1.
<PC2UCLM>-IPERI = 1.
<PC2UCLM>-BONDT = 1.
ENDLOOP.

LOOP AT IT_PC2UCLM INTO WA_PC2UCLM.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PC2UCLM-CKDAT, sy-vline,
WA_PC2UCLM-CBDAT, sy-vline,
WA_PC2UCLM-REPYR, sy-vline,
WA_PC2UCLM-ABKRS, sy-vline,
WA_PC2UCLM-PAYTY, sy-vline,
WA_PC2UCLM-PAYID, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PC2UCLM you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PC2UCLM TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PC2UCLM INTO WA_PC2UCLM. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PC2UCLM_STR,
SEQNO TYPE STRING,
LGART TYPE STRING,
FPPER TYPE STRING,
IPERI TYPE STRING,
BONDT TYPE STRING,
CKDAT TYPE STRING,
CBDAT TYPE STRING,
REPYR TYPE STRING,
ABKRS TYPE STRING,
PAYTY TYPE STRING,
PAYID TYPE STRING,
JUPER TYPE STRING,
OVHRS TYPE STRING,
OBHRS TYPE STRING,
OVAMT TYPE STRING,
OBAMT TYPE STRING,
WAERS TYPE STRING,
INDRI TYPE STRING,
REAMT TYPE STRING,
PFGRV TYPE STRING,
TFGRV TYPE STRING,
PERNR TYPE STRING,
SUBTY TYPE STRING,
OBJPS TYPE STRING,
SPRPS TYPE STRING,
ENDDA TYPE STRING,
BEGDA TYPE STRING,
SEQNR TYPE STRING,
APZNR TYPE STRING,
C1ZNR TYPE STRING,
IPEND TYPE STRING,
INPTY TYPE STRING,
INPID TYPE STRING,
OSEQN TYPE STRING,END OF T_EKKO_STR. DATA: WA_PC2UCLM_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PC2UCLM_STR-SEQNO sy-vline
WA_PC2UCLM_STR-LGART sy-vline
WA_PC2UCLM_STR-FPPER sy-vline
WA_PC2UCLM_STR-IPERI sy-vline
WA_PC2UCLM_STR-BONDT sy-vline
WA_PC2UCLM_STR-CKDAT sy-vline
WA_PC2UCLM_STR-CBDAT sy-vline
WA_PC2UCLM_STR-REPYR sy-vline
WA_PC2UCLM_STR-ABKRS sy-vline
WA_PC2UCLM_STR-PAYTY sy-vline
WA_PC2UCLM_STR-PAYID sy-vline
WA_PC2UCLM_STR-JUPER sy-vline
WA_PC2UCLM_STR-OVHRS sy-vline
WA_PC2UCLM_STR-OBHRS sy-vline
WA_PC2UCLM_STR-OVAMT sy-vline
WA_PC2UCLM_STR-OBAMT sy-vline
WA_PC2UCLM_STR-WAERS sy-vline
WA_PC2UCLM_STR-INDRI sy-vline
WA_PC2UCLM_STR-REAMT sy-vline
WA_PC2UCLM_STR-PFGRV sy-vline
WA_PC2UCLM_STR-TFGRV sy-vline
WA_PC2UCLM_STR-PERNR sy-vline
WA_PC2UCLM_STR-SUBTY sy-vline
WA_PC2UCLM_STR-OBJPS sy-vline
WA_PC2UCLM_STR-SPRPS sy-vline
WA_PC2UCLM_STR-ENDDA sy-vline
WA_PC2UCLM_STR-BEGDA sy-vline
WA_PC2UCLM_STR-SEQNR sy-vline
WA_PC2UCLM_STR-APZNR sy-vline
WA_PC2UCLM_STR-C1ZNR sy-vline
WA_PC2UCLM_STR-IPEND sy-vline
WA_PC2UCLM_STR-INPTY sy-vline
WA_PC2UCLM_STR-INPID sy-vline
WA_PC2UCLM_STR-OSEQN sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.