ABAP Select data from SAP table PC2U5 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PC2U5 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PC2U5. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PC2U5 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PC2U5 TYPE STANDARD TABLE OF PC2U5,
      WA_PC2U5 TYPE PC2U5,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PC2U5> TYPE PC2U5.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PC2U5.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PC2U5
  INTO TABLE IT_PC2U5.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PC2U5
*  INTO TABLE @DATA(IT_PC2U52).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PC2U5 INDEX 1 INTO DATA(WA_PC2U52).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PC2U5 ASSIGNING <PC2U5>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PC2U5>-TAXAU = 1.
<PC2U5>-TAXTY = 1.
<PC2U5>-FRMNR = 1.
<PC2U5>-EXIND = 1.
ENDLOOP.

LOOP AT IT_PC2U5 INTO WA_PC2U5.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline, ENDLOOP.
   
*Add any further fields from structure WA_PC2U5 you want to display...

  WRITE:/ sy-uline.
* Aternatively use generic code to Write field values (and NAME) to screen report
  DO.
    ASSIGN COMPONENT sy-index OF STRUCTURE wa_PC2U5 TO <field>.
    IF sy-subrc <> 0. EXIT. ENDIF.
    WRITE:/ 'Field Value', <field>, sy-vline.
    gd_str = <field> .
    lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ).
    lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ).
    WRITE:/ 'Field Name', lv_fieldname.
  ENDDO.

  
*Redo loop but convert all fields from internal to out value  
LOOP AT IT_PC2U5 INTO WA_PC2U5.


*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Convert all fields to display/output versions using conversion routines
  PERFORM convert_all_field_values CHANGING wa_EKKO.
	 
ENDLOOP.

  
*&---------------------------------------------------------------------*
*& Form convert_all_field_values
*&---------------------------------------------------------------------*
FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO.
DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit TXTYP, internal->external for field TAXTY CALL FUNCTION 'CONVERSION_EXIT_TXTYP_OUTPUT' EXPORTING input = WA_PC2U5-TAXTY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PC2U5-TAXTY.
WRITE:/ 'New Value:', ld_input.

*Conversion exit P10FM, internal->external for field FRMNR CALL FUNCTION 'CONVERSION_EXIT_P10FM_OUTPUT' EXPORTING input = WA_PC2U5-FRMNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PC2U5-FRMNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PC2U5_STR,
TAXAU TYPE STRING,
TAXTY TYPE STRING,
FRMNR TYPE STRING,
EXIND TYPE STRING,END OF T_EKKO_STR. DATA: WA_PC2U5_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PC2U5_STR-TAXAU sy-vline
WA_PC2U5_STR-TAXTY sy-vline
WA_PC2U5_STR-FRMNR sy-vline
WA_PC2U5_STR-EXIND sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.