ABAP Select data from SAP table PC2L6 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PC2L6 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PC2L6. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PC2L6 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PC2L6 TYPE STANDARD TABLE OF PC2L6,
      WA_PC2L6 TYPE PC2L6,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PC2L6> TYPE PC2L6.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PC2L6.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PC2L6
  INTO TABLE IT_PC2L6.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PC2L6
*  INTO TABLE @DATA(IT_PC2L62).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PC2L6 INDEX 1 INTO DATA(WA_PC2L62).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PC2L6 ASSIGNING <PC2L6>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PC2L6>-IONUM = 1.
<PC2L6>-JURIS = 1.
<PC2L6>-GCATE = 1.
<PC2L6>-IOPRI = 1.
<PC2L6>-ORDDA = 1.
ENDLOOP.

LOOP AT IT_PC2L6 INTO WA_PC2L6.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PC2L6-PAYTY, sy-vline,
WA_PC2L6-PERMO, sy-vline,
WA_PC2L6-PABRD, sy-vline,
WA_PC2L6-LABRD, sy-vline,
WA_PC2L6-PABRP, sy-vline,
WA_PC2L6-PABRJ, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PC2L6 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PC2L6 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PC2L6 INTO WA_PC2L6. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit GJAHR, internal->external for field PABRJ CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_PC2L6-PABRJ IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PC2L6-PABRJ.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field CYEAR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_PC2L6-CYEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PC2L6-CYEAR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PC2L6_STR,
IONUM TYPE STRING,
JURIS TYPE STRING,
GCATE TYPE STRING,
IOPRI TYPE STRING,
ORDDA TYPE STRING,
PAYTY TYPE STRING,
PERMO TYPE STRING,
PABRD TYPE STRING,
LABRD TYPE STRING,
PABRP TYPE STRING,
PABRJ TYPE STRING,
ZEINH TYPE STRING,
CMONT TYPE STRING,
CYEAR TYPE STRING,
BABRP TYPE STRING,
EABRP TYPE STRING,
NPPYA TYPE STRING,
DATMO TYPE STRING,
IORCD TYPE STRING,
IOSTS TYPE STRING,END OF T_EKKO_STR. DATA: WA_PC2L6_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PC2L6_STR-IONUM sy-vline
WA_PC2L6_STR-JURIS sy-vline
WA_PC2L6_STR-GCATE sy-vline
WA_PC2L6_STR-IOPRI sy-vline
WA_PC2L6_STR-ORDDA sy-vline
WA_PC2L6_STR-PAYTY sy-vline
WA_PC2L6_STR-PERMO sy-vline
WA_PC2L6_STR-PABRD sy-vline
WA_PC2L6_STR-LABRD sy-vline
WA_PC2L6_STR-PABRP sy-vline
WA_PC2L6_STR-PABRJ sy-vline
WA_PC2L6_STR-ZEINH sy-vline
WA_PC2L6_STR-CMONT sy-vline
WA_PC2L6_STR-CYEAR sy-vline
WA_PC2L6_STR-BABRP sy-vline
WA_PC2L6_STR-EABRP sy-vline
WA_PC2L6_STR-NPPYA sy-vline
WA_PC2L6_STR-DATMO sy-vline
WA_PC2L6_STR-IORCD sy-vline
WA_PC2L6_STR-IOSTS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.