ABAP Select data from SAP table PC2G7 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PC2G7 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PC2G7. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PC2G7 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PC2G7 TYPE STANDARD TABLE OF PC2G7,
      WA_PC2G7 TYPE PC2G7,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PC2G7> TYPE PC2G7.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PC2G7.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PC2G7
  INTO TABLE IT_PC2G7.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PC2G7
*  INTO TABLE @DATA(IT_PC2G72).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PC2G7 INDEX 1 INTO DATA(WA_PC2G72).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PC2G7 ASSIGNING <PC2G7>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PC2G7>-BEGDA = 1.
<PC2G7>-ENDDA = 1.
<PC2G7>-NBTGK = 1.
<PC2G7>-WTTKL = 1.
<PC2G7>-LFZFR = 1.
ENDLOOP.

LOOP AT IT_PC2G7 INTO WA_PC2G7.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PC2G7-LFZZH, sy-vline,
WA_PC2G7-LFZSO, sy-vline,
WA_PC2G7-KGZFR, sy-vline,
WA_PC2G7-KGZZH, sy-vline,
WA_PC2G7-PRBZT, sy-vline,
WA_PC2G7-PRBEH, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PC2G7 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PC2G7 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PC2G7 INTO WA_PC2G7. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PC2G7_STR,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
NBTGK TYPE STRING,
WTTKL TYPE STRING,
LFZFR TYPE STRING,
LFZZH TYPE STRING,
LFZSO TYPE STRING,
KGZFR TYPE STRING,
KGZZH TYPE STRING,
PRBZT TYPE STRING,
PRBEH TYPE STRING,
KDGFR TYPE STRING,
KDGF2 TYPE STRING,
ARBER TYPE STRING,
EINDT TYPE STRING,
KONDT TYPE STRING,
KONSL TYPE STRING,
CTTYP TYPE STRING,
CTEDT TYPE STRING,
PERSG TYPE STRING,
PERSK TYPE STRING,
WRKPL TYPE STRING,
CTBEG TYPE STRING,
CTNUM TYPE STRING,
OBJNB TYPE STRING,
CREDT TYPE STRING,
LPROT TYPE STRING,
ERNPN TYPE STRING,
ERNPU TYPE STRING,
EENPN TYPE STRING,
EENPU TYPE STRING,END OF T_EKKO_STR. DATA: WA_PC2G7_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PC2G7_STR-BEGDA sy-vline
WA_PC2G7_STR-ENDDA sy-vline
WA_PC2G7_STR-NBTGK sy-vline
WA_PC2G7_STR-WTTKL sy-vline
WA_PC2G7_STR-LFZFR sy-vline
WA_PC2G7_STR-LFZZH sy-vline
WA_PC2G7_STR-LFZSO sy-vline
WA_PC2G7_STR-KGZFR sy-vline
WA_PC2G7_STR-KGZZH sy-vline
WA_PC2G7_STR-PRBZT sy-vline
WA_PC2G7_STR-PRBEH sy-vline
WA_PC2G7_STR-KDGFR sy-vline
WA_PC2G7_STR-KDGF2 sy-vline
WA_PC2G7_STR-ARBER sy-vline
WA_PC2G7_STR-EINDT sy-vline
WA_PC2G7_STR-KONDT sy-vline
WA_PC2G7_STR-KONSL sy-vline
WA_PC2G7_STR-CTTYP sy-vline
WA_PC2G7_STR-CTEDT sy-vline
WA_PC2G7_STR-PERSG sy-vline
WA_PC2G7_STR-PERSK sy-vline
WA_PC2G7_STR-WRKPL sy-vline
WA_PC2G7_STR-CTBEG sy-vline
WA_PC2G7_STR-CTNUM sy-vline
WA_PC2G7_STR-OBJNB sy-vline
WA_PC2G7_STR-CREDT sy-vline
WA_PC2G7_STR-LPROT sy-vline
WA_PC2G7_STR-ERNPN sy-vline
WA_PC2G7_STR-ERNPU sy-vline
WA_PC2G7_STR-EENPN sy-vline
WA_PC2G7_STR-EENPU sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.