ABAP Select data from SAP table PC2FI_CSI into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PC2FI_CSI table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PC2FI_CSI. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PC2FI_CSI table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PC2FI_CSI TYPE STANDARD TABLE OF PC2FI_CSI,
      WA_PC2FI_CSI TYPE PC2FI_CSI,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PC2FI_CSI> TYPE PC2FI_CSI.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PC2FI_CSI.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PC2FI_CSI
  INTO TABLE IT_PC2FI_CSI.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PC2FI_CSI
*  INTO TABLE @DATA(IT_PC2FI_CSI2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PC2FI_CSI INDEX 1 INTO DATA(WA_PC2FI_CSI2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PC2FI_CSI ASSIGNING <PC2FI_CSI>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PC2FI_CSI>-CNTR1 = 1.
<PC2FI_CSI>-BEGDA = 1.
<PC2FI_CSI>-ENDDA = 1.
<PC2FI_CSI>-IDP = 1.
<PC2FI_CSI>-INGR = 1.
ENDLOOP.

LOOP AT IT_PC2FI_CSI INTO WA_PC2FI_CSI.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PC2FI_CSI-INDP, sy-vline,
WA_PC2FI_CSI-EMFSL, sy-vline,
WA_PC2FI_CSI-CONNR, sy-vline,
WA_PC2FI_CSI-REFNO, sy-vline,
WA_PC2FI_CSI-INCODE, sy-vline,
WA_PC2FI_CSI-ERPER, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PC2FI_CSI you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PC2FI_CSI TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PC2FI_CSI INTO WA_PC2FI_CSI. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PC2FI_CSI_STR,
CNTR1 TYPE STRING,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
IDP TYPE STRING,
INGR TYPE STRING,
INDP TYPE STRING,
EMFSL TYPE STRING,
CONNR TYPE STRING,
REFNO TYPE STRING,
INCODE TYPE STRING,
ERPER TYPE STRING,
IDA TYPE STRING,
ACRSGR TYPE STRING,
UNGR TYPE STRING,
EMFSLI TYPE STRING,
CONNRI TYPE STRING,
IDP2 TYPE STRING,
IDA2 TYPE STRING,END OF T_EKKO_STR. DATA: WA_PC2FI_CSI_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PC2FI_CSI_STR-CNTR1 sy-vline
WA_PC2FI_CSI_STR-BEGDA sy-vline
WA_PC2FI_CSI_STR-ENDDA sy-vline
WA_PC2FI_CSI_STR-IDP sy-vline
WA_PC2FI_CSI_STR-INGR sy-vline
WA_PC2FI_CSI_STR-INDP sy-vline
WA_PC2FI_CSI_STR-EMFSL sy-vline
WA_PC2FI_CSI_STR-CONNR sy-vline
WA_PC2FI_CSI_STR-REFNO sy-vline
WA_PC2FI_CSI_STR-INCODE sy-vline
WA_PC2FI_CSI_STR-ERPER sy-vline
WA_PC2FI_CSI_STR-IDA sy-vline
WA_PC2FI_CSI_STR-ACRSGR sy-vline
WA_PC2FI_CSI_STR-UNGR sy-vline
WA_PC2FI_CSI_STR-EMFSLI sy-vline
WA_PC2FI_CSI_STR-CONNRI sy-vline
WA_PC2FI_CSI_STR-IDP2 sy-vline
WA_PC2FI_CSI_STR-IDA2 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.