ABAP Select data from SAP table PC2C8 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PC2C8 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PC2C8. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PC2C8 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PC2C8 TYPE STANDARD TABLE OF PC2C8,
      WA_PC2C8 TYPE PC2C8,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PC2C8> TYPE PC2C8.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PC2C8.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PC2C8
  INTO TABLE IT_PC2C8.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PC2C8
*  INTO TABLE @DATA(IT_PC2C82).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PC2C8 INDEX 1 INTO DATA(WA_PC2C82).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PC2C8 ASSIGNING <PC2C8>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PC2C8>-CNTR1 = 1.
<PC2C8>-BEGDA = 1.
<PC2C8>-ENDDA = 1.
<PC2C8>-LISTU = 1.
<PC2C8>-LICAT = 1.
ENDLOOP.

LOOP AT IT_PC2C8 INTO WA_PC2C8.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PC2C8-INAMT, sy-vline,
WA_PC2C8-INCUR, sy-vline,
WA_PC2C8-ERPAY, sy-vline,
WA_PC2C8-DISAB, sy-vline,
WA_PC2C8-SSIPE, sy-vline,
WA_PC2C8-BRCOD, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PC2C8 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PC2C8 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PC2C8 INTO WA_PC2C8. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PC2C8_STR,
CNTR1 TYPE STRING,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
LISTU TYPE STRING,
LICAT TYPE STRING,
INAMT TYPE STRING,
INCUR TYPE STRING,
ERPAY TYPE STRING,
DISAB TYPE STRING,
SSIPE TYPE STRING,
BRCOD TYPE STRING,
IDNUM TYPE STRING,
LIDAY TYPE STRING,
SIREP TYPE STRING,
UNEMS TYPE STRING,
OCUST TYPE STRING,
LIEXP TYPE STRING,
EIEXP TYPE STRING,
ERLIE TYPE STRING,
EREIE TYPE STRING,
EEEIE TYPE STRING,
EROCE TYPE STRING,
ERDFE TYPE STRING,
FRTWS TYPE STRING,END OF T_EKKO_STR. DATA: WA_PC2C8_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PC2C8_STR-CNTR1 sy-vline
WA_PC2C8_STR-BEGDA sy-vline
WA_PC2C8_STR-ENDDA sy-vline
WA_PC2C8_STR-LISTU sy-vline
WA_PC2C8_STR-LICAT sy-vline
WA_PC2C8_STR-INAMT sy-vline
WA_PC2C8_STR-INCUR sy-vline
WA_PC2C8_STR-ERPAY sy-vline
WA_PC2C8_STR-DISAB sy-vline
WA_PC2C8_STR-SSIPE sy-vline
WA_PC2C8_STR-BRCOD sy-vline
WA_PC2C8_STR-IDNUM sy-vline
WA_PC2C8_STR-LIDAY sy-vline
WA_PC2C8_STR-SIREP sy-vline
WA_PC2C8_STR-UNEMS sy-vline
WA_PC2C8_STR-OCUST sy-vline
WA_PC2C8_STR-LIEXP sy-vline
WA_PC2C8_STR-EIEXP sy-vline
WA_PC2C8_STR-ERLIE sy-vline
WA_PC2C8_STR-EREIE sy-vline
WA_PC2C8_STR-EEEIE sy-vline
WA_PC2C8_STR-EROCE sy-vline
WA_PC2C8_STR-ERDFE sy-vline
WA_PC2C8_STR-FRTWS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.