ABAP Select data from SAP table PC274 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PC274 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PC274. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PC274 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PC274 TYPE STANDARD TABLE OF PC274,
      WA_PC274 TYPE PC274,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PC274> TYPE PC274.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PC274.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PC274
  INTO TABLE IT_PC274.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PC274
*  INTO TABLE @DATA(IT_PC2742).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PC274 INDEX 1 INTO DATA(WA_PC2742).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PC274 ASSIGNING <PC274>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PC274>-SEQNO = 1.
<PC274>-MTATB = 1.
<PC274>-SAART = 1.
<PC274>-VSNUM = 1.
<PC274>-KTONR = 1.
ENDLOOP.

LOOP AT IT_PC274 INTO WA_PC274.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PC274-VTSCH, sy-vline,
WA_PC274-NAMEK, sy-vline,
WA_PC274-GBDAT, sy-vline,
WA_PC274-NAMED, sy-vline,
WA_PC274-BGDAT, sy-vline,
WA_PC274-VSBEG, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PC274 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PC274 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PC274 INTO WA_PC274. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PC274_STR,
SEQNO TYPE STRING,
MTATB TYPE STRING,
SAART TYPE STRING,
VSNUM TYPE STRING,
KTONR TYPE STRING,
VTSCH TYPE STRING,
NAMEK TYPE STRING,
GBDAT TYPE STRING,
NAMED TYPE STRING,
BGDAT TYPE STRING,
VSBEG TYPE STRING,
GVSBE TYPE STRING,
GBNAM TYPE STRING,
GBORT TYPE STRING,
RVNUM TYPE STRING,
GESCH TYPE STRING,
TTART TYPE STRING,
BEART TYPE STRING,
SWTBE TYPE STRING,
ARBEG TYPE STRING,
AWGRD TYPE STRING,
TRWAZ TYPE STRING,
IRWAZ TYPE STRING,
VVZVE TYPE STRING,
ARGZU TYPE STRING,
BEZVE TYPE STRING,
ZWVER TYPE STRING,
FLD01 TYPE STRING,
FLD02 TYPE STRING,
FLD03 TYPE STRING,
FLD04 TYPE STRING,
MELDA TYPE STRING,
LOEDA TYPE STRING,
KZALT TYPE STRING,END OF T_EKKO_STR. DATA: WA_PC274_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PC274_STR-SEQNO sy-vline
WA_PC274_STR-MTATB sy-vline
WA_PC274_STR-SAART sy-vline
WA_PC274_STR-VSNUM sy-vline
WA_PC274_STR-KTONR sy-vline
WA_PC274_STR-VTSCH sy-vline
WA_PC274_STR-NAMEK sy-vline
WA_PC274_STR-GBDAT sy-vline
WA_PC274_STR-NAMED sy-vline
WA_PC274_STR-BGDAT sy-vline
WA_PC274_STR-VSBEG sy-vline
WA_PC274_STR-GVSBE sy-vline
WA_PC274_STR-GBNAM sy-vline
WA_PC274_STR-GBORT sy-vline
WA_PC274_STR-RVNUM sy-vline
WA_PC274_STR-GESCH sy-vline
WA_PC274_STR-TTART sy-vline
WA_PC274_STR-BEART sy-vline
WA_PC274_STR-SWTBE sy-vline
WA_PC274_STR-ARBEG sy-vline
WA_PC274_STR-AWGRD sy-vline
WA_PC274_STR-TRWAZ sy-vline
WA_PC274_STR-IRWAZ sy-vline
WA_PC274_STR-VVZVE sy-vline
WA_PC274_STR-ARGZU sy-vline
WA_PC274_STR-BEZVE sy-vline
WA_PC274_STR-ZWVER sy-vline
WA_PC274_STR-FLD01 sy-vline
WA_PC274_STR-FLD02 sy-vline
WA_PC274_STR-FLD03 sy-vline
WA_PC274_STR-FLD04 sy-vline
WA_PC274_STR-MELDA sy-vline
WA_PC274_STR-LOEDA sy-vline
WA_PC274_STR-KZALT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.