ABAP Select data from SAP table PC21T into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PC21T table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PC21T. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PC21T table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PC21T TYPE STANDARD TABLE OF PC21T,
      WA_PC21T TYPE PC21T,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PC21T> TYPE PC21T.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PC21T.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PC21T
  INTO TABLE IT_PC21T.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PC21T
*  INTO TABLE @DATA(IT_PC21T2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PC21T INDEX 1 INTO DATA(WA_PC21T2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PC21T ASSIGNING <PC21T>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PC21T>-RVNUM = 1.
<PC21T>-SAKEN = 1.
<PC21T>-VTRAE = 1.
<PC21T>-ABNRA = 1.
<PC21T>-ABEGJ = 1.
ENDLOOP.

LOOP AT IT_PC21T INTO WA_PC21T.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PC21T-ABEGD, sy-vline,
WA_PC21T-ATTKK, sy-vline,
WA_PC21T-AABGR, sy-vline,
WA_PC21T-BNRAS, sy-vline,
WA_PC21T-BEGJD, sy-vline,
WA_PC21T-BEGDD, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PC21T you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PC21T TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PC21T INTO WA_PC21T. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PC21T_STR,
RVNUM TYPE STRING,
SAKEN TYPE STRING,
VTRAE TYPE STRING,
ABNRA TYPE STRING,
ABEGJ TYPE STRING,
ABEGD TYPE STRING,
ATTKK TYPE STRING,
AABGR TYPE STRING,
BNRAS TYPE STRING,
BEGJD TYPE STRING,
BEGDD TYPE STRING,
TTKKN TYPE STRING,
ABGRD TYPE STRING,
FILL1 TYPE STRING,
PERNR TYPE STRING,
IDENT TYPE STRING,
NACHN TYPE STRING,
VORNA TYPE STRING,
BNRKK TYPE STRING,
LEER1 TYPE STRING,
SVSCH TYPE STRING,
AUSBG TYPE STRING,
LEER2 TYPE STRING,END OF T_EKKO_STR. DATA: WA_PC21T_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PC21T_STR-RVNUM sy-vline
WA_PC21T_STR-SAKEN sy-vline
WA_PC21T_STR-VTRAE sy-vline
WA_PC21T_STR-ABNRA sy-vline
WA_PC21T_STR-ABEGJ sy-vline
WA_PC21T_STR-ABEGD sy-vline
WA_PC21T_STR-ATTKK sy-vline
WA_PC21T_STR-AABGR sy-vline
WA_PC21T_STR-BNRAS sy-vline
WA_PC21T_STR-BEGJD sy-vline
WA_PC21T_STR-BEGDD sy-vline
WA_PC21T_STR-TTKKN sy-vline
WA_PC21T_STR-ABGRD sy-vline
WA_PC21T_STR-FILL1 sy-vline
WA_PC21T_STR-PERNR sy-vline
WA_PC21T_STR-IDENT sy-vline
WA_PC21T_STR-NACHN sy-vline
WA_PC21T_STR-VORNA sy-vline
WA_PC21T_STR-BNRKK sy-vline
WA_PC21T_STR-LEER1 sy-vline
WA_PC21T_STR-SVSCH sy-vline
WA_PC21T_STR-AUSBG sy-vline
WA_PC21T_STR-LEER2 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.