ABAP Select data from SAP table PC1I6 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PC1I6 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PC1I6. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PC1I6 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PC1I6 TYPE STANDARD TABLE OF PC1I6,
      WA_PC1I6 TYPE PC1I6,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PC1I6> TYPE PC1I6.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PC1I6.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PC1I6
  INTO TABLE IT_PC1I6.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PC1I6
*  INTO TABLE @DATA(IT_PC1I62).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PC1I6 INDEX 1 INTO DATA(WA_PC1I62).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PC1I6 ASSIGNING <PC1I6>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PC1I6>-UEYEAR = 1.
<PC1I6>-UEMONTH = 1.
<PC1I6>-GENDATE = 1.
<PC1I6>-GENTIME = 1.
<PC1I6>-BUKRS = 1.
ENDLOOP.

LOOP AT IT_PC1I6 INTO WA_PC1I6.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PC1I6-MODMN, sy-vline,
WA_PC1I6-INPSC, sy-vline,
WA_PC1I6-INPSM, sy-vline,
WA_PC1I6-SEDEL, sy-vline,
WA_PC1I6-SEDEZ, sy-vline,
WA_PC1I6-SDINPS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PC1I6 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PC1I6 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PC1I6 INTO WA_PC1I6. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PC1I6_STR,
UEYEAR TYPE STRING,
UEMONTH TYPE STRING,
GENDATE TYPE STRING,
GENTIME TYPE STRING,
BUKRS TYPE STRING,
MODMN TYPE STRING,
INPSC TYPE STRING,
INPSM TYPE STRING,
SEDEL TYPE STRING,
SEDEZ TYPE STRING,
SDINPS TYPE STRING,
REGIO TYPE STRING,
MATCE TYPE STRING,
CFMIT TYPE STRING,
RSMIT TYPE STRING,
CFAZIE TYPE STRING,
CAP TYPE STRING,
ISTAT TYPE STRING,
ISTA2 TYPE STRING,
WAERS TYPE STRING,
INPDAP TYPE STRING,
CODGROUP TYPE STRING,
ACTIVITY TYPE STRING,
COMPANY_ID TYPE STRING,
LABOR_TYPE TYPE STRING,
TPR_COMPANY_ID TYPE STRING,END OF T_EKKO_STR. DATA: WA_PC1I6_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PC1I6_STR-UEYEAR sy-vline
WA_PC1I6_STR-UEMONTH sy-vline
WA_PC1I6_STR-GENDATE sy-vline
WA_PC1I6_STR-GENTIME sy-vline
WA_PC1I6_STR-BUKRS sy-vline
WA_PC1I6_STR-MODMN sy-vline
WA_PC1I6_STR-INPSC sy-vline
WA_PC1I6_STR-INPSM sy-vline
WA_PC1I6_STR-SEDEL sy-vline
WA_PC1I6_STR-SEDEZ sy-vline
WA_PC1I6_STR-SDINPS sy-vline
WA_PC1I6_STR-REGIO sy-vline
WA_PC1I6_STR-MATCE sy-vline
WA_PC1I6_STR-CFMIT sy-vline
WA_PC1I6_STR-RSMIT sy-vline
WA_PC1I6_STR-CFAZIE sy-vline
WA_PC1I6_STR-CAP sy-vline
WA_PC1I6_STR-ISTAT sy-vline
WA_PC1I6_STR-ISTA2 sy-vline
WA_PC1I6_STR-WAERS sy-vline
WA_PC1I6_STR-INPDAP sy-vline
WA_PC1I6_STR-CODGROUP sy-vline
WA_PC1I6_STR-ACTIVITY sy-vline
WA_PC1I6_STR-COMPANY_ID sy-vline
WA_PC1I6_STR-LABOR_TYPE sy-vline
WA_PC1I6_STR-TPR_COMPANY_ID sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.