ABAP Select data from SAP table PAMODCTDP_CC into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PAMODCTDP_CC table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PAMODCTDP_CC. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PAMODCTDP_CC table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PAMODCTDP_CC TYPE STANDARD TABLE OF PAMODCTDP_CC,
      WA_PAMODCTDP_CC TYPE PAMODCTDP_CC,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PAMODCTDP_CC> TYPE PAMODCTDP_CC.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PAMODCTDP_CC.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PAMODCTDP_CC
  INTO TABLE IT_PAMODCTDP_CC.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PAMODCTDP_CC
*  INTO TABLE @DATA(IT_PAMODCTDP_CC2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PAMODCTDP_CC INDEX 1 INTO DATA(WA_PAMODCTDP_CC2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PAMODCTDP_CC ASSIGNING <PAMODCTDP_CC>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PAMODCTDP_CC>-PAGUID = 1.
<PAMODCTDP_CC>-AENNR = 1.
<PAMODCTDP_CC>-PNGUID = 1.
<PAMODCTDP_CC>-VERSIOID = 1.
<PAMODCTDP_CC>-DATEF = 1.
ENDLOOP.

LOOP AT IT_PAMODCTDP_CC INTO WA_PAMODCTDP_CC.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PAMODCTDP_CC-CAPREQ, sy-vline,
WA_PAMODCTDP_CC-CAPREQFIX, sy-vline,
WA_PAMODCTDP_CC-UNITC, sy-vline,
WA_PAMODCTDP_CC-BUCKETVAR, sy-vline,
WA_PAMODCTDP_CC-BUCKETFIX, sy-vline,
WA_PAMODCTDP_CC-BUCKETUNIT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PAMODCTDP_CC you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PAMODCTDP_CC TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PAMODCTDP_CC INTO WA_PAMODCTDP_CC. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field AENNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PAMODCTDP_CC-AENNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PAMODCTDP_CC-AENNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNITC CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PAMODCTDP_CC-UNITC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PAMODCTDP_CC-UNITC.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field BUCKETUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PAMODCTDP_CC-BUCKETUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PAMODCTDP_CC-BUCKETUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field NEXT_AENNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PAMODCTDP_CC-NEXT_AENNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PAMODCTDP_CC-NEXT_AENNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PAMODCTDP_CC_STR,
PAGUID TYPE STRING,
AENNR TYPE STRING,
PNGUID TYPE STRING,
VERSIOID TYPE STRING,
DATEF TYPE STRING,
CAPREQ TYPE STRING,
CAPREQFIX TYPE STRING,
UNITC TYPE STRING,
BUCKETVAR TYPE STRING,
BUCKETFIX TYPE STRING,
BUCKETUNIT TYPE STRING,
AENNR_DATUV TYPE STRING,
NEXT_AENNR TYPE STRING,
NEXT_AENNR_DATUV TYPE STRING,
VRSIOEX TYPE STRING,
VALIDITY TYPE STRING,END OF T_EKKO_STR. DATA: WA_PAMODCTDP_CC_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PAMODCTDP_CC_STR-PAGUID sy-vline
WA_PAMODCTDP_CC_STR-AENNR sy-vline
WA_PAMODCTDP_CC_STR-PNGUID sy-vline
WA_PAMODCTDP_CC_STR-VERSIOID sy-vline
WA_PAMODCTDP_CC_STR-DATEF sy-vline
WA_PAMODCTDP_CC_STR-CAPREQ sy-vline
WA_PAMODCTDP_CC_STR-CAPREQFIX sy-vline
WA_PAMODCTDP_CC_STR-UNITC sy-vline
WA_PAMODCTDP_CC_STR-BUCKETVAR sy-vline
WA_PAMODCTDP_CC_STR-BUCKETFIX sy-vline
WA_PAMODCTDP_CC_STR-BUCKETUNIT sy-vline
WA_PAMODCTDP_CC_STR-AENNR_DATUV sy-vline
WA_PAMODCTDP_CC_STR-NEXT_AENNR sy-vline
WA_PAMODCTDP_CC_STR-NEXT_AENNR_DATUV sy-vline
WA_PAMODCTDP_CC_STR-VRSIOEX sy-vline
WA_PAMODCTDP_CC_STR-VALIDITY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.