ABAP Select data from SAP table PAMOD_DYNP_900 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PAMOD_DYNP_900 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PAMOD_DYNP_900. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PAMOD_DYNP_900 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PAMOD_DYNP_900 TYPE STANDARD TABLE OF PAMOD_DYNP_900,
      WA_PAMOD_DYNP_900 TYPE PAMOD_DYNP_900,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PAMOD_DYNP_900> TYPE PAMOD_DYNP_900.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PAMOD_DYNP_900.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PAMOD_DYNP_900
  INTO TABLE IT_PAMOD_DYNP_900.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PAMOD_DYNP_900
*  INTO TABLE @DATA(IT_PAMOD_DYNP_9002).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PAMOD_DYNP_900 INDEX 1 INTO DATA(WA_PAMOD_DYNP_9002).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PAMOD_DYNP_900 ASSIGNING <PAMOD_DYNP_900>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PAMOD_DYNP_900>-PALTID_DESC = 1.
<PAMOD_DYNP_900>-PAGUID = 1.
<PAMOD_DYNP_900>-PAMDCNT = 1.
<PAMOD_DYNP_900>-MARK = 1.
<PAMOD_DYNP_900>-ALTNUM = 1.
ENDLOOP.

LOOP AT IT_PAMOD_DYNP_900 INTO WA_PAMOD_DYNP_900.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PAMOD_DYNP_900-TEXT, sy-vline,
WA_PAMOD_DYNP_900-RES_NAME, sy-vline,
WA_PAMOD_DYNP_900-CLASS, sy-vline,
WA_PAMOD_DYNP_900-KLART, sy-vline,
WA_PAMOD_DYNP_900-CLINT, sy-vline,
WA_PAMOD_DYNP_900-ICON, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PAMOD_DYNP_900 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PAMOD_DYNP_900 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PAMOD_DYNP_900 INTO WA_PAMOD_DYNP_900. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field ALTNUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PAMOD_DYNP_900-ALTNUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PAMOD_DYNP_900-ALTNUM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNITC CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PAMOD_DYNP_900-UNITC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PAMOD_DYNP_900-UNITC.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNITD_FIX CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PAMOD_DYNP_900-UNITD_FIX IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PAMOD_DYNP_900-UNITD_FIX.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field BUCKETUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PAMOD_DYNP_900-BUCKETUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PAMOD_DYNP_900-BUCKETUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AENNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PAMOD_DYNP_900-AENNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PAMOD_DYNP_900-AENNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNITD CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PAMOD_DYNP_900-UNITD IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PAMOD_DYNP_900-UNITD.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MAX_BREAK_TUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PAMOD_DYNP_900-MAX_BREAK_TUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PAMOD_DYNP_900-MAX_BREAK_TUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TADUR, internal->external for field TADUR_N CALL FUNCTION 'CONVERSION_EXIT_TADUR_OUTPUT' EXPORTING input = WA_PAMOD_DYNP_900-TADUR_N IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PAMOD_DYNP_900-TADUR_N.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TADUR, internal->external for field TADUR_B CALL FUNCTION 'CONVERSION_EXIT_TADUR_OUTPUT' EXPORTING input = WA_PAMOD_DYNP_900-TADUR_B IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PAMOD_DYNP_900-TADUR_B.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PAMOD_DYNP_900_STR,
PALTID_DESC TYPE STRING,
PAGUID TYPE STRING,
PAMDCNT TYPE STRING,
MARK TYPE STRING,
ALTNUM TYPE STRING,
TEXT TYPE STRING,
RES_NAME TYPE STRING,
CLASS TYPE STRING,
KLART TYPE STRING,
CLINT TYPE STRING,
ICON TYPE STRING,
PNTEXT TYPE STRING,
RESTYPE TYPE STRING,
RESTYPE_DESC TYPE STRING,
GREYFLG TYPE STRING,
LONGTEXT TYPE STRING,
MOD_PRIO_EXT TYPE STRING,
VWEA_TEXT TYPE STRING,
CAPREQ TYPE STRING,
CAPREQFIX TYPE STRING,
CRQVAR TYPE STRING,
CRQFIX TYPE STRING,
UNITC TYPE STRING,
DIMID TYPE STRING,
UNITD_FIX TYPE STRING,
BUCKETVAR TYPE STRING,
BUCKETFIX TYPE STRING,
BUCKETUNIT TYPE STRING,
BUCKETDIMID TYPE STRING,
RPNAME TYPE STRING,
KNOBJ_STATUS TYPE STRING,
LOCEXT TYPE STRING,
AENNR TYPE STRING,
DELFLG TYPE STRING,
PNGUID TYPE STRING,
LOCID TYPE STRING,
UNITD TYPE STRING,
DURATION TYPE STRING,
DURRND TYPE STRING,
TAUSE TYPE STRING,
TAIDSAP TYPE STRING,
PRIO TYPE STRING,
VWEA TYPE STRING,
DURVAR TYPE STRING,
DURFIX TYPE STRING,
RESUID TYPE STRING,
DURATION_FIX TYPE STRING,
DURRND_MODE TYPE STRING,
MAX_BREAK TYPE STRING,
MAX_BREAK_TUNIT TYPE STRING,
MAX_BREAK_USE TYPE STRING,
SLOT_START TYPE STRING,
PROD_IN_SHIFT TYPE STRING,
RPGUID TYPE STRING,
MODE_KNOBJ TYPE STRING,
TADUR_N TYPE STRING,
TADUR_B TYPE STRING,
CODE TYPE STRING,
TA_STATUS TYPE STRING,END OF T_EKKO_STR. DATA: WA_PAMOD_DYNP_900_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PAMOD_DYNP_900_STR-PALTID_DESC sy-vline
WA_PAMOD_DYNP_900_STR-PAGUID sy-vline
WA_PAMOD_DYNP_900_STR-PAMDCNT sy-vline
WA_PAMOD_DYNP_900_STR-MARK sy-vline
WA_PAMOD_DYNP_900_STR-ALTNUM sy-vline
WA_PAMOD_DYNP_900_STR-TEXT sy-vline
WA_PAMOD_DYNP_900_STR-RES_NAME sy-vline
WA_PAMOD_DYNP_900_STR-CLASS sy-vline
WA_PAMOD_DYNP_900_STR-KLART sy-vline
WA_PAMOD_DYNP_900_STR-CLINT sy-vline
WA_PAMOD_DYNP_900_STR-ICON sy-vline
WA_PAMOD_DYNP_900_STR-PNTEXT sy-vline
WA_PAMOD_DYNP_900_STR-RESTYPE sy-vline
WA_PAMOD_DYNP_900_STR-RESTYPE_DESC sy-vline
WA_PAMOD_DYNP_900_STR-GREYFLG sy-vline
WA_PAMOD_DYNP_900_STR-LONGTEXT sy-vline
WA_PAMOD_DYNP_900_STR-MOD_PRIO_EXT sy-vline
WA_PAMOD_DYNP_900_STR-VWEA_TEXT sy-vline
WA_PAMOD_DYNP_900_STR-CAPREQ sy-vline
WA_PAMOD_DYNP_900_STR-CAPREQFIX sy-vline
WA_PAMOD_DYNP_900_STR-CRQVAR sy-vline
WA_PAMOD_DYNP_900_STR-CRQFIX sy-vline
WA_PAMOD_DYNP_900_STR-UNITC sy-vline
WA_PAMOD_DYNP_900_STR-DIMID sy-vline
WA_PAMOD_DYNP_900_STR-UNITD_FIX sy-vline
WA_PAMOD_DYNP_900_STR-BUCKETVAR sy-vline
WA_PAMOD_DYNP_900_STR-BUCKETFIX sy-vline
WA_PAMOD_DYNP_900_STR-BUCKETUNIT sy-vline
WA_PAMOD_DYNP_900_STR-BUCKETDIMID sy-vline
WA_PAMOD_DYNP_900_STR-RPNAME sy-vline
WA_PAMOD_DYNP_900_STR-KNOBJ_STATUS sy-vline
WA_PAMOD_DYNP_900_STR-LOCEXT sy-vline
WA_PAMOD_DYNP_900_STR-AENNR sy-vline
WA_PAMOD_DYNP_900_STR-DELFLG sy-vline
WA_PAMOD_DYNP_900_STR-PNGUID sy-vline
WA_PAMOD_DYNP_900_STR-LOCID sy-vline
WA_PAMOD_DYNP_900_STR-UNITD sy-vline
WA_PAMOD_DYNP_900_STR-DURATION sy-vline
WA_PAMOD_DYNP_900_STR-DURRND sy-vline
WA_PAMOD_DYNP_900_STR-TAUSE sy-vline
WA_PAMOD_DYNP_900_STR-TAIDSAP sy-vline
WA_PAMOD_DYNP_900_STR-PRIO sy-vline
WA_PAMOD_DYNP_900_STR-VWEA sy-vline
WA_PAMOD_DYNP_900_STR-DURVAR sy-vline
WA_PAMOD_DYNP_900_STR-DURFIX sy-vline
WA_PAMOD_DYNP_900_STR-RESUID sy-vline
WA_PAMOD_DYNP_900_STR-DURATION_FIX sy-vline
WA_PAMOD_DYNP_900_STR-DURRND_MODE sy-vline
WA_PAMOD_DYNP_900_STR-MAX_BREAK sy-vline
WA_PAMOD_DYNP_900_STR-MAX_BREAK_TUNIT sy-vline
WA_PAMOD_DYNP_900_STR-MAX_BREAK_USE sy-vline
WA_PAMOD_DYNP_900_STR-SLOT_START sy-vline
WA_PAMOD_DYNP_900_STR-PROD_IN_SHIFT sy-vline
WA_PAMOD_DYNP_900_STR-RPGUID sy-vline
WA_PAMOD_DYNP_900_STR-MODE_KNOBJ sy-vline
WA_PAMOD_DYNP_900_STR-TADUR_N sy-vline
WA_PAMOD_DYNP_900_STR-TADUR_B sy-vline
WA_PAMOD_DYNP_900_STR-CODE sy-vline
WA_PAMOD_DYNP_900_STR-TA_STATUS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.