ABAP Select data from SAP table PAD_SFEC_CE_HIGHER_DUTY into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PAD_SFEC_CE_HIGHER_DUTY table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PAD_SFEC_CE_HIGHER_DUTY. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PAD_SFEC_CE_HIGHER_DUTY table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PAD_SFEC_CE_HIGHER_DUTY TYPE STANDARD TABLE OF PAD_SFEC_CE_HIGHER_DUTY,
      WA_PAD_SFEC_CE_HIGHER_DUTY TYPE PAD_SFEC_CE_HIGHER_DUTY,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PAD_SFEC_CE_HIGHER_DUTY> TYPE PAD_SFEC_CE_HIGHER_DUTY.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PAD_SFEC_CE_HIGHER_DUTY.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PAD_SFEC_CE_HIGHER_DUTY
  INTO TABLE IT_PAD_SFEC_CE_HIGHER_DUTY.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PAD_SFEC_CE_HIGHER_DUTY
*  INTO TABLE @DATA(IT_PAD_SFEC_CE_HIGHER_DUTY2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PAD_SFEC_CE_HIGHER_DUTY INDEX 1 INTO DATA(WA_PAD_SFEC_CE_HIGHER_DUTY2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PAD_SFEC_CE_HIGHER_DUTY ASSIGNING <PAD_SFEC_CE_HIGHER_DUTY>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PAD_SFEC_CE_HIGHER_DUTY>-MDFSYSTEMEFFECTIVESTARTDATE = 1.
<PAD_SFEC_CE_HIGHER_DUTY>-EFFECTIVEENDDATE = 1.
<PAD_SFEC_CE_HIGHER_DUTY>-HDTEMPREFERENCEPOSITION = 1.
<PAD_SFEC_CE_HIGHER_DUTY>-PERCENTAGEHDTEMP = 1.
<PAD_SFEC_CE_HIGHER_DUTY>-VALUE = 1.
ENDLOOP.

LOOP AT IT_PAD_SFEC_CE_HIGHER_DUTY INTO WA_PAD_SFEC_CE_HIGHER_DUTY.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PAD_SFEC_CE_HIGHER_DUTY-COSTASSIGNMENT, sy-vline,
WA_PAD_SFEC_CE_HIGHER_DUTY-S17INDICATOR, sy-vline,
WA_PAD_SFEC_CE_HIGHER_DUTY-ALLOWANCEBASIS, sy-vline,
WA_PAD_SFEC_CE_HIGHER_DUTY-PERCENTAGEALLOWANCE, sy-vline,
WA_PAD_SFEC_CE_HIGHER_DUTY-VALUE, sy-vline,
WA_PAD_SFEC_CE_HIGHER_DUTY-HDTEMPREFERENCESALARYFROMPERSO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PAD_SFEC_CE_HIGHER_DUTY you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PAD_SFEC_CE_HIGHER_DUTY TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PAD_SFEC_CE_HIGHER_DUTY INTO WA_PAD_SFEC_CE_HIGHER_DUTY. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PAD_SFEC_CE_HIGHER_DUTY_STR,
MDFSYSTEMEFFECTIVESTARTDATE TYPE STRING,
EFFECTIVEENDDATE TYPE STRING,
HDTEMPREFERENCEPOSITION TYPE STRING,
PERCENTAGEHDTEMP TYPE STRING,
VALUE TYPE STRING,
COSTASSIGNMENT TYPE STRING,
S17INDICATOR TYPE STRING,
ALLOWANCEBASIS TYPE STRING,
PERCENTAGEALLOWANCE TYPE STRING,
VALUE TYPE STRING,
HDTEMPREFERENCESALARYFROMPERSO TYPE STRING,
COUNTINGRULE TYPE STRING,
DISCARDLESSTHANHALFDAY TYPE STRING,
HDTEMPREFERENCEUSERID TYPE STRING,
SUBREFERENCEUSERID TYPE STRING,
HDTEMPREFERENCESALARY TYPE STRING,
VALUE TYPE STRING,
SUBSTANTIVEREFERENCESALARY TYPE STRING,
VALUE TYPE STRING,
RESPONSIBILITYTYPE TYPE STRING,
_VALUE_LIST TYPE STRING,
SUBSTANTIVEREFSALARYPAYCOMP TYPE STRING,
HDTEMPREFSALARYPAYCOMP TYPE STRING,
SUBSTANTIVEREFSALARYADJUSTEDAM TYPE STRING,
VALUE TYPE STRING,
HDTEMPREFSALARYADJUSTEDAMT TYPE STRING,
VALUE TYPE STRING,
SUBSTANTIVEAMTSCURRENCY TYPE STRING,
HDTEMPAMTSCURRENCY TYPE STRING,END OF T_EKKO_STR. DATA: WA_PAD_SFEC_CE_HIGHER_DUTY_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PAD_SFEC_CE_HIGHER_DUTY_STR-MDFSYSTEMEFFECTIVESTARTDATE sy-vline
WA_PAD_SFEC_CE_HIGHER_DUTY_STR-EFFECTIVEENDDATE sy-vline
WA_PAD_SFEC_CE_HIGHER_DUTY_STR-HDTEMPREFERENCEPOSITION sy-vline
WA_PAD_SFEC_CE_HIGHER_DUTY_STR-PERCENTAGEHDTEMP sy-vline
WA_PAD_SFEC_CE_HIGHER_DUTY_STR-VALUE sy-vline
WA_PAD_SFEC_CE_HIGHER_DUTY_STR-COSTASSIGNMENT sy-vline
WA_PAD_SFEC_CE_HIGHER_DUTY_STR-S17INDICATOR sy-vline
WA_PAD_SFEC_CE_HIGHER_DUTY_STR-ALLOWANCEBASIS sy-vline
WA_PAD_SFEC_CE_HIGHER_DUTY_STR-PERCENTAGEALLOWANCE sy-vline
WA_PAD_SFEC_CE_HIGHER_DUTY_STR-VALUE sy-vline
WA_PAD_SFEC_CE_HIGHER_DUTY_STR-HDTEMPREFERENCESALARYFROMPERSO sy-vline
WA_PAD_SFEC_CE_HIGHER_DUTY_STR-COUNTINGRULE sy-vline
WA_PAD_SFEC_CE_HIGHER_DUTY_STR-DISCARDLESSTHANHALFDAY sy-vline
WA_PAD_SFEC_CE_HIGHER_DUTY_STR-HDTEMPREFERENCEUSERID sy-vline
WA_PAD_SFEC_CE_HIGHER_DUTY_STR-SUBREFERENCEUSERID sy-vline
WA_PAD_SFEC_CE_HIGHER_DUTY_STR-HDTEMPREFERENCESALARY sy-vline
WA_PAD_SFEC_CE_HIGHER_DUTY_STR-VALUE sy-vline
WA_PAD_SFEC_CE_HIGHER_DUTY_STR-SUBSTANTIVEREFERENCESALARY sy-vline
WA_PAD_SFEC_CE_HIGHER_DUTY_STR-VALUE sy-vline
WA_PAD_SFEC_CE_HIGHER_DUTY_STR-RESPONSIBILITYTYPE sy-vline
WA_PAD_SFEC_CE_HIGHER_DUTY_STR-_VALUE_LIST sy-vline
WA_PAD_SFEC_CE_HIGHER_DUTY_STR-SUBSTANTIVEREFSALARYPAYCOMP sy-vline
WA_PAD_SFEC_CE_HIGHER_DUTY_STR-HDTEMPREFSALARYPAYCOMP sy-vline
WA_PAD_SFEC_CE_HIGHER_DUTY_STR-SUBSTANTIVEREFSALARYADJUSTEDAM sy-vline
WA_PAD_SFEC_CE_HIGHER_DUTY_STR-VALUE sy-vline
WA_PAD_SFEC_CE_HIGHER_DUTY_STR-HDTEMPREFSALARYADJUSTEDAMT sy-vline
WA_PAD_SFEC_CE_HIGHER_DUTY_STR-VALUE sy-vline
WA_PAD_SFEC_CE_HIGHER_DUTY_STR-SUBSTANTIVEAMTSCURRENCY sy-vline
WA_PAD_SFEC_CE_HIGHER_DUTY_STR-HDTEMPAMTSCURRENCY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.