ABAP Select data from SAP table PA3339 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PA3339 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PA3339. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PA3339 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PA3339 TYPE STANDARD TABLE OF PA3339,
      WA_PA3339 TYPE PA3339,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PA3339> TYPE PA3339.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PA3339.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PA3339
  INTO TABLE IT_PA3339.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PA3339
*  INTO TABLE @DATA(IT_PA33392).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PA3339 INDEX 1 INTO DATA(WA_PA33392).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PA3339 ASSIGNING <PA3339>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PA3339>-MANDT = 1.
<PA3339>-PERNR = 1.
<PA3339>-SUBTY = 1.
<PA3339>-OBJPS = 1.
<PA3339>-SPRPS = 1.
ENDLOOP.

LOOP AT IT_PA3339 INTO WA_PA3339.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PA3339-ENDDA, sy-vline,
WA_PA3339-BEGDA, sy-vline,
WA_PA3339-SEQNR, sy-vline,
WA_PA3339-AEDTM, sy-vline,
WA_PA3339-UNAME, sy-vline,
WA_PA3339-HISTO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PA3339 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PA3339 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PA3339 INTO WA_PA3339. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit GJAHR, internal->external for field RPAYR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_PA3339-RPAYR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PA3339-RPAYR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PA3339_STR,
MANDT TYPE STRING,
PERNR TYPE STRING,
SUBTY TYPE STRING,
OBJPS TYPE STRING,
SPRPS TYPE STRING,
ENDDA TYPE STRING,
BEGDA TYPE STRING,
SEQNR TYPE STRING,
AEDTM TYPE STRING,
UNAME TYPE STRING,
HISTO TYPE STRING,
ITXEX TYPE STRING,
REFEX TYPE STRING,
ORDEX TYPE STRING,
ITBLD TYPE STRING,
PREAS TYPE STRING,
FLAG1 TYPE STRING,
FLAG2 TYPE STRING,
FLAG3 TYPE STRING,
FLAG4 TYPE STRING,
RESE1 TYPE STRING,
RESE2 TYPE STRING,
GRPVL TYPE STRING,
RPTYP TYPE STRING,
RPMTH TYPE STRING,
RPAYR TYPE STRING,
PCHSD TYPE STRING,
TDAMT TYPE STRING,
TDCUR TYPE STRING,
ITAMT TYPE STRING,
ITCUR TYPE STRING,
LGART TYPE STRING,
FRAMT TYPE STRING,
FRCUR TYPE STRING,END OF T_EKKO_STR. DATA: WA_PA3339_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PA3339_STR-MANDT sy-vline
WA_PA3339_STR-PERNR sy-vline
WA_PA3339_STR-SUBTY sy-vline
WA_PA3339_STR-OBJPS sy-vline
WA_PA3339_STR-SPRPS sy-vline
WA_PA3339_STR-ENDDA sy-vline
WA_PA3339_STR-BEGDA sy-vline
WA_PA3339_STR-SEQNR sy-vline
WA_PA3339_STR-AEDTM sy-vline
WA_PA3339_STR-UNAME sy-vline
WA_PA3339_STR-HISTO sy-vline
WA_PA3339_STR-ITXEX sy-vline
WA_PA3339_STR-REFEX sy-vline
WA_PA3339_STR-ORDEX sy-vline
WA_PA3339_STR-ITBLD sy-vline
WA_PA3339_STR-PREAS sy-vline
WA_PA3339_STR-FLAG1 sy-vline
WA_PA3339_STR-FLAG2 sy-vline
WA_PA3339_STR-FLAG3 sy-vline
WA_PA3339_STR-FLAG4 sy-vline
WA_PA3339_STR-RESE1 sy-vline
WA_PA3339_STR-RESE2 sy-vline
WA_PA3339_STR-GRPVL sy-vline
WA_PA3339_STR-RPTYP sy-vline
WA_PA3339_STR-RPMTH sy-vline
WA_PA3339_STR-RPAYR sy-vline
WA_PA3339_STR-PCHSD sy-vline
WA_PA3339_STR-TDAMT sy-vline
WA_PA3339_STR-TDCUR sy-vline
WA_PA3339_STR-ITAMT sy-vline
WA_PA3339_STR-ITCUR sy-vline
WA_PA3339_STR-LGART sy-vline
WA_PA3339_STR-FRAMT sy-vline
WA_PA3339_STR-FRCUR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.