ABAP Select data from SAP table PA3220 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PA3220 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PA3220. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PA3220 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PA3220 TYPE STANDARD TABLE OF PA3220,
      WA_PA3220 TYPE PA3220,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PA3220> TYPE PA3220.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PA3220.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PA3220
  INTO TABLE IT_PA3220.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PA3220
*  INTO TABLE @DATA(IT_PA32202).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PA3220 INDEX 1 INTO DATA(WA_PA32202).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PA3220 ASSIGNING <PA3220>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PA3220>-MANDT = 1.
<PA3220>-PERNR = 1.
<PA3220>-SUBTY = 1.
<PA3220>-OBJPS = 1.
<PA3220>-SPRPS = 1.
ENDLOOP.

LOOP AT IT_PA3220 INTO WA_PA3220.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PA3220-ENDDA, sy-vline,
WA_PA3220-BEGDA, sy-vline,
WA_PA3220-SEQNR, sy-vline,
WA_PA3220-AEDTM, sy-vline,
WA_PA3220-UNAME, sy-vline,
WA_PA3220-HISTO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PA3220 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PA3220 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PA3220 INTO WA_PA3220. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PA3220_STR,
MANDT TYPE STRING,
PERNR TYPE STRING,
SUBTY TYPE STRING,
OBJPS TYPE STRING,
SPRPS TYPE STRING,
ENDDA TYPE STRING,
BEGDA TYPE STRING,
SEQNR TYPE STRING,
AEDTM TYPE STRING,
UNAME TYPE STRING,
HISTO TYPE STRING,
ITXEX TYPE STRING,
REFEX TYPE STRING,
ORDEX TYPE STRING,
ITBLD TYPE STRING,
PREAS TYPE STRING,
FLAG1 TYPE STRING,
FLAG2 TYPE STRING,
FLAG3 TYPE STRING,
FLAG4 TYPE STRING,
RESE1 TYPE STRING,
RESE2 TYPE STRING,
GRPVL TYPE STRING,
KAD TYPE STRING,
SPIKA TYPE STRING,
SPINS TYPE STRING,
KPK TYPE STRING,
DEPAR TYPE STRING,
ALLDA TYPE STRING,
FSCHD TYPE STRING,
AMKA TYPE STRING,
TYINS TYPE STRING,
RGIKA TYPE STRING,
SIF01 TYPE STRING,
ENT01 TYPE STRING,
EN201 TYPE STRING,
DGR01 TYPE STRING,
REG01 TYPE STRING,
PRE01 TYPE STRING,
AME01 TYPE STRING,
PRR01 TYPE STRING,
AMR01 TYPE STRING,
SIF02 TYPE STRING,
ENT02 TYPE STRING,
EN202 TYPE STRING,
DGR02 TYPE STRING,
REG02 TYPE STRING,
PRE02 TYPE STRING,
AME02 TYPE STRING,
PRR02 TYPE STRING,
AMR02 TYPE STRING,
SIF03 TYPE STRING,
ENT03 TYPE STRING,
EN203 TYPE STRING,
DGR03 TYPE STRING,
REG03 TYPE STRING,
PRE03 TYPE STRING,
AME03 TYPE STRING,
PRR03 TYPE STRING,
AMR03 TYPE STRING,
SIF04 TYPE STRING,
ENT04 TYPE STRING,
EN204 TYPE STRING,
DGR04 TYPE STRING,
REG04 TYPE STRING,
PRE04 TYPE STRING,
AME04 TYPE STRING,
PRR04 TYPE STRING,
AMR04 TYPE STRING,
SIF05 TYPE STRING,
ENT05 TYPE STRING,
EN205 TYPE STRING,
DGR05 TYPE STRING,
REG05 TYPE STRING,
PRE05 TYPE STRING,
AME05 TYPE STRING,
PRR05 TYPE STRING,
AMR05 TYPE STRING,
SIF06 TYPE STRING,
ENT06 TYPE STRING,
EN206 TYPE STRING,
DGR06 TYPE STRING,
REG06 TYPE STRING,
PRE06 TYPE STRING,
AME06 TYPE STRING,
PRR06 TYPE STRING,
AMR06 TYPE STRING,
SIF07 TYPE STRING,
ENT07 TYPE STRING,
EN207 TYPE STRING,
DGR07 TYPE STRING,
REG07 TYPE STRING,
PRE07 TYPE STRING,
AME07 TYPE STRING,
PRR07 TYPE STRING,
AMR07 TYPE STRING,
SIF08 TYPE STRING,
ENT08 TYPE STRING,
EN208 TYPE STRING,
DGR08 TYPE STRING,
REG08 TYPE STRING,
PRE08 TYPE STRING,
AME08 TYPE STRING,
PRR08 TYPE STRING,
AMR08 TYPE STRING,
SIF09 TYPE STRING,
ENT09 TYPE STRING,
EN209 TYPE STRING,
DGR09 TYPE STRING,
REG09 TYPE STRING,
PRE09 TYPE STRING,
AME09 TYPE STRING,
PRR09 TYPE STRING,
AMR09 TYPE STRING,
SIF10 TYPE STRING,
ENT10 TYPE STRING,
EN210 TYPE STRING,
DGR10 TYPE STRING,
REG10 TYPE STRING,
PRE10 TYPE STRING,
AME10 TYPE STRING,
PRR10 TYPE STRING,
AMR10 TYPE STRING,
SIF11 TYPE STRING,
ENT11 TYPE STRING,
EN211 TYPE STRING,
DGR11 TYPE STRING,
REG11 TYPE STRING,
PRE11 TYPE STRING,
AME11 TYPE STRING,
PRR11 TYPE STRING,
AMR11 TYPE STRING,
SIF12 TYPE STRING,
ENT12 TYPE STRING,
EN212 TYPE STRING,
DGR12 TYPE STRING,
REG12 TYPE STRING,
PRE12 TYPE STRING,
AME12 TYPE STRING,
PRR12 TYPE STRING,
AMR12 TYPE STRING,
SIF13 TYPE STRING,
ENT13 TYPE STRING,
EN213 TYPE STRING,
DGR13 TYPE STRING,
REG13 TYPE STRING,
PRE13 TYPE STRING,
AME13 TYPE STRING,
PRR13 TYPE STRING,
AMR13 TYPE STRING,
SIF14 TYPE STRING,
ENT14 TYPE STRING,
EN214 TYPE STRING,
DGR14 TYPE STRING,
REG14 TYPE STRING,
PRE14 TYPE STRING,
AME14 TYPE STRING,
PRR14 TYPE STRING,
AMR14 TYPE STRING,
SIF15 TYPE STRING,
ENT15 TYPE STRING,
EN215 TYPE STRING,
DGR15 TYPE STRING,
REG15 TYPE STRING,
PRE15 TYPE STRING,
AME15 TYPE STRING,
PRR15 TYPE STRING,
AMR15 TYPE STRING,
WAERS TYPE STRING,
LMTSM TYPE STRING,END OF T_EKKO_STR. DATA: WA_PA3220_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PA3220_STR-MANDT sy-vline
WA_PA3220_STR-PERNR sy-vline
WA_PA3220_STR-SUBTY sy-vline
WA_PA3220_STR-OBJPS sy-vline
WA_PA3220_STR-SPRPS sy-vline
WA_PA3220_STR-ENDDA sy-vline
WA_PA3220_STR-BEGDA sy-vline
WA_PA3220_STR-SEQNR sy-vline
WA_PA3220_STR-AEDTM sy-vline
WA_PA3220_STR-UNAME sy-vline
WA_PA3220_STR-HISTO sy-vline
WA_PA3220_STR-ITXEX sy-vline
WA_PA3220_STR-REFEX sy-vline
WA_PA3220_STR-ORDEX sy-vline
WA_PA3220_STR-ITBLD sy-vline
WA_PA3220_STR-PREAS sy-vline
WA_PA3220_STR-FLAG1 sy-vline
WA_PA3220_STR-FLAG2 sy-vline
WA_PA3220_STR-FLAG3 sy-vline
WA_PA3220_STR-FLAG4 sy-vline
WA_PA3220_STR-RESE1 sy-vline
WA_PA3220_STR-RESE2 sy-vline
WA_PA3220_STR-GRPVL sy-vline
WA_PA3220_STR-KAD sy-vline
WA_PA3220_STR-SPIKA sy-vline
WA_PA3220_STR-SPINS sy-vline
WA_PA3220_STR-KPK sy-vline
WA_PA3220_STR-DEPAR sy-vline
WA_PA3220_STR-ALLDA sy-vline
WA_PA3220_STR-FSCHD sy-vline
WA_PA3220_STR-AMKA sy-vline
WA_PA3220_STR-TYINS sy-vline
WA_PA3220_STR-RGIKA sy-vline
WA_PA3220_STR-SIF01 sy-vline
WA_PA3220_STR-ENT01 sy-vline
WA_PA3220_STR-EN201 sy-vline
WA_PA3220_STR-DGR01 sy-vline
WA_PA3220_STR-REG01 sy-vline
WA_PA3220_STR-PRE01 sy-vline
WA_PA3220_STR-AME01 sy-vline
WA_PA3220_STR-PRR01 sy-vline
WA_PA3220_STR-AMR01 sy-vline
WA_PA3220_STR-SIF02 sy-vline
WA_PA3220_STR-ENT02 sy-vline
WA_PA3220_STR-EN202 sy-vline
WA_PA3220_STR-DGR02 sy-vline
WA_PA3220_STR-REG02 sy-vline
WA_PA3220_STR-PRE02 sy-vline
WA_PA3220_STR-AME02 sy-vline
WA_PA3220_STR-PRR02 sy-vline
WA_PA3220_STR-AMR02 sy-vline
WA_PA3220_STR-SIF03 sy-vline
WA_PA3220_STR-ENT03 sy-vline
WA_PA3220_STR-EN203 sy-vline
WA_PA3220_STR-DGR03 sy-vline
WA_PA3220_STR-REG03 sy-vline
WA_PA3220_STR-PRE03 sy-vline
WA_PA3220_STR-AME03 sy-vline
WA_PA3220_STR-PRR03 sy-vline
WA_PA3220_STR-AMR03 sy-vline
WA_PA3220_STR-SIF04 sy-vline
WA_PA3220_STR-ENT04 sy-vline
WA_PA3220_STR-EN204 sy-vline
WA_PA3220_STR-DGR04 sy-vline
WA_PA3220_STR-REG04 sy-vline
WA_PA3220_STR-PRE04 sy-vline
WA_PA3220_STR-AME04 sy-vline
WA_PA3220_STR-PRR04 sy-vline
WA_PA3220_STR-AMR04 sy-vline
WA_PA3220_STR-SIF05 sy-vline
WA_PA3220_STR-ENT05 sy-vline
WA_PA3220_STR-EN205 sy-vline
WA_PA3220_STR-DGR05 sy-vline
WA_PA3220_STR-REG05 sy-vline
WA_PA3220_STR-PRE05 sy-vline
WA_PA3220_STR-AME05 sy-vline
WA_PA3220_STR-PRR05 sy-vline
WA_PA3220_STR-AMR05 sy-vline
WA_PA3220_STR-SIF06 sy-vline
WA_PA3220_STR-ENT06 sy-vline
WA_PA3220_STR-EN206 sy-vline
WA_PA3220_STR-DGR06 sy-vline
WA_PA3220_STR-REG06 sy-vline
WA_PA3220_STR-PRE06 sy-vline
WA_PA3220_STR-AME06 sy-vline
WA_PA3220_STR-PRR06 sy-vline
WA_PA3220_STR-AMR06 sy-vline
WA_PA3220_STR-SIF07 sy-vline
WA_PA3220_STR-ENT07 sy-vline
WA_PA3220_STR-EN207 sy-vline
WA_PA3220_STR-DGR07 sy-vline
WA_PA3220_STR-REG07 sy-vline
WA_PA3220_STR-PRE07 sy-vline
WA_PA3220_STR-AME07 sy-vline
WA_PA3220_STR-PRR07 sy-vline
WA_PA3220_STR-AMR07 sy-vline
WA_PA3220_STR-SIF08 sy-vline
WA_PA3220_STR-ENT08 sy-vline
WA_PA3220_STR-EN208 sy-vline
WA_PA3220_STR-DGR08 sy-vline
WA_PA3220_STR-REG08 sy-vline
WA_PA3220_STR-PRE08 sy-vline
WA_PA3220_STR-AME08 sy-vline
WA_PA3220_STR-PRR08 sy-vline
WA_PA3220_STR-AMR08 sy-vline
WA_PA3220_STR-SIF09 sy-vline
WA_PA3220_STR-ENT09 sy-vline
WA_PA3220_STR-EN209 sy-vline
WA_PA3220_STR-DGR09 sy-vline
WA_PA3220_STR-REG09 sy-vline
WA_PA3220_STR-PRE09 sy-vline
WA_PA3220_STR-AME09 sy-vline
WA_PA3220_STR-PRR09 sy-vline
WA_PA3220_STR-AMR09 sy-vline
WA_PA3220_STR-SIF10 sy-vline
WA_PA3220_STR-ENT10 sy-vline
WA_PA3220_STR-EN210 sy-vline
WA_PA3220_STR-DGR10 sy-vline
WA_PA3220_STR-REG10 sy-vline
WA_PA3220_STR-PRE10 sy-vline
WA_PA3220_STR-AME10 sy-vline
WA_PA3220_STR-PRR10 sy-vline
WA_PA3220_STR-AMR10 sy-vline
WA_PA3220_STR-SIF11 sy-vline
WA_PA3220_STR-ENT11 sy-vline
WA_PA3220_STR-EN211 sy-vline
WA_PA3220_STR-DGR11 sy-vline
WA_PA3220_STR-REG11 sy-vline
WA_PA3220_STR-PRE11 sy-vline
WA_PA3220_STR-AME11 sy-vline
WA_PA3220_STR-PRR11 sy-vline
WA_PA3220_STR-AMR11 sy-vline
WA_PA3220_STR-SIF12 sy-vline
WA_PA3220_STR-ENT12 sy-vline
WA_PA3220_STR-EN212 sy-vline
WA_PA3220_STR-DGR12 sy-vline
WA_PA3220_STR-REG12 sy-vline
WA_PA3220_STR-PRE12 sy-vline
WA_PA3220_STR-AME12 sy-vline
WA_PA3220_STR-PRR12 sy-vline
WA_PA3220_STR-AMR12 sy-vline
WA_PA3220_STR-SIF13 sy-vline
WA_PA3220_STR-ENT13 sy-vline
WA_PA3220_STR-EN213 sy-vline
WA_PA3220_STR-DGR13 sy-vline
WA_PA3220_STR-REG13 sy-vline
WA_PA3220_STR-PRE13 sy-vline
WA_PA3220_STR-AME13 sy-vline
WA_PA3220_STR-PRR13 sy-vline
WA_PA3220_STR-AMR13 sy-vline
WA_PA3220_STR-SIF14 sy-vline
WA_PA3220_STR-ENT14 sy-vline
WA_PA3220_STR-EN214 sy-vline
WA_PA3220_STR-DGR14 sy-vline
WA_PA3220_STR-REG14 sy-vline
WA_PA3220_STR-PRE14 sy-vline
WA_PA3220_STR-AME14 sy-vline
WA_PA3220_STR-PRR14 sy-vline
WA_PA3220_STR-AMR14 sy-vline
WA_PA3220_STR-SIF15 sy-vline
WA_PA3220_STR-ENT15 sy-vline
WA_PA3220_STR-EN215 sy-vline
WA_PA3220_STR-DGR15 sy-vline
WA_PA3220_STR-REG15 sy-vline
WA_PA3220_STR-PRE15 sy-vline
WA_PA3220_STR-AME15 sy-vline
WA_PA3220_STR-PRR15 sy-vline
WA_PA3220_STR-AMR15 sy-vline
WA_PA3220_STR-WAERS sy-vline
WA_PA3220_STR-LMTSM sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.