ABAP Select data from SAP table PA0962 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PA0962 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PA0962. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PA0962 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PA0962 TYPE STANDARD TABLE OF PA0962,
      WA_PA0962 TYPE PA0962,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PA0962> TYPE PA0962.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PA0962.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PA0962
  INTO TABLE IT_PA0962.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PA0962
*  INTO TABLE @DATA(IT_PA09622).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PA0962 INDEX 1 INTO DATA(WA_PA09622).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PA0962 ASSIGNING <PA0962>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PA0962>-MANDT = 1.
<PA0962>-PERNR = 1.
<PA0962>-SUBTY = 1.
<PA0962>-OBJPS = 1.
<PA0962>-SPRPS = 1.
ENDLOOP.

LOOP AT IT_PA0962 INTO WA_PA0962.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PA0962-ENDDA, sy-vline,
WA_PA0962-BEGDA, sy-vline,
WA_PA0962-SEQNR, sy-vline,
WA_PA0962-AEDTM, sy-vline,
WA_PA0962-UNAME, sy-vline,
WA_PA0962-HISTO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PA0962 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PA0962 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PA0962 INTO WA_PA0962. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PA0962_STR,
MANDT TYPE STRING,
PERNR TYPE STRING,
SUBTY TYPE STRING,
OBJPS TYPE STRING,
SPRPS TYPE STRING,
ENDDA TYPE STRING,
BEGDA TYPE STRING,
SEQNR TYPE STRING,
AEDTM TYPE STRING,
UNAME TYPE STRING,
HISTO TYPE STRING,
ITXEX TYPE STRING,
REFEX TYPE STRING,
ORDEX TYPE STRING,
ITBLD TYPE STRING,
PREAS TYPE STRING,
FLAG1 TYPE STRING,
FLAG2 TYPE STRING,
FLAG3 TYPE STRING,
FLAG4 TYPE STRING,
RESE1 TYPE STRING,
RESE2 TYPE STRING,
GRPVL TYPE STRING,
RSDRT TYPE STRING,
LGART TYPE STRING,
OPKEN TYPE STRING,
BETRG TYPE STRING,
WAERS TYPE STRING,
RSREA TYPE STRING,
RSADT TYPE STRING,
RSFMD TYPE STRING,
RSLBD TYPE STRING,
RSLED TYPE STRING,
RSDAS TYPE STRING,
RSEIC TYPE STRING,
RSNBR TYPE STRING,
LGBFA TYPE STRING,
RSBFA TYPE STRING,
WABFA TYPE STRING,
RSAMT TYPE STRING,
WAAMT TYPE STRING,
RSPCN TYPE STRING,
RSWAI TYPE STRING,
RSSCR TYPE STRING,
RSCOR TYPE STRING,
RSLLN TYPE STRING,
RSHNO TYPE STRING,
RSSTR TYPE STRING,
RSAPT TYPE STRING,
RSCTY TYPE STRING,
RSSTA TYPE STRING,
RSCRY TYPE STRING,
RSPST TYPE STRING,
RSTEL TYPE STRING,
EMAIL TYPE STRING,
RSDSA TYPE STRING,
RSODP TYPE STRING,
RSBFD TYPE STRING,END OF T_EKKO_STR. DATA: WA_PA0962_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PA0962_STR-MANDT sy-vline
WA_PA0962_STR-PERNR sy-vline
WA_PA0962_STR-SUBTY sy-vline
WA_PA0962_STR-OBJPS sy-vline
WA_PA0962_STR-SPRPS sy-vline
WA_PA0962_STR-ENDDA sy-vline
WA_PA0962_STR-BEGDA sy-vline
WA_PA0962_STR-SEQNR sy-vline
WA_PA0962_STR-AEDTM sy-vline
WA_PA0962_STR-UNAME sy-vline
WA_PA0962_STR-HISTO sy-vline
WA_PA0962_STR-ITXEX sy-vline
WA_PA0962_STR-REFEX sy-vline
WA_PA0962_STR-ORDEX sy-vline
WA_PA0962_STR-ITBLD sy-vline
WA_PA0962_STR-PREAS sy-vline
WA_PA0962_STR-FLAG1 sy-vline
WA_PA0962_STR-FLAG2 sy-vline
WA_PA0962_STR-FLAG3 sy-vline
WA_PA0962_STR-FLAG4 sy-vline
WA_PA0962_STR-RESE1 sy-vline
WA_PA0962_STR-RESE2 sy-vline
WA_PA0962_STR-GRPVL sy-vline
WA_PA0962_STR-RSDRT sy-vline
WA_PA0962_STR-LGART sy-vline
WA_PA0962_STR-OPKEN sy-vline
WA_PA0962_STR-BETRG sy-vline
WA_PA0962_STR-WAERS sy-vline
WA_PA0962_STR-RSREA sy-vline
WA_PA0962_STR-RSADT sy-vline
WA_PA0962_STR-RSFMD sy-vline
WA_PA0962_STR-RSLBD sy-vline
WA_PA0962_STR-RSLED sy-vline
WA_PA0962_STR-RSDAS sy-vline
WA_PA0962_STR-RSEIC sy-vline
WA_PA0962_STR-RSNBR sy-vline
WA_PA0962_STR-LGBFA sy-vline
WA_PA0962_STR-RSBFA sy-vline
WA_PA0962_STR-WABFA sy-vline
WA_PA0962_STR-RSAMT sy-vline
WA_PA0962_STR-WAAMT sy-vline
WA_PA0962_STR-RSPCN sy-vline
WA_PA0962_STR-RSWAI sy-vline
WA_PA0962_STR-RSSCR sy-vline
WA_PA0962_STR-RSCOR sy-vline
WA_PA0962_STR-RSLLN sy-vline
WA_PA0962_STR-RSHNO sy-vline
WA_PA0962_STR-RSSTR sy-vline
WA_PA0962_STR-RSAPT sy-vline
WA_PA0962_STR-RSCTY sy-vline
WA_PA0962_STR-RSSTA sy-vline
WA_PA0962_STR-RSCRY sy-vline
WA_PA0962_STR-RSPST sy-vline
WA_PA0962_STR-RSTEL sy-vline
WA_PA0962_STR-EMAIL sy-vline
WA_PA0962_STR-RSDSA sy-vline
WA_PA0962_STR-RSODP sy-vline
WA_PA0962_STR-RSBFD sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.