ABAP Select data from SAP table PA0875 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PA0875 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PA0875. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PA0875 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PA0875 TYPE STANDARD TABLE OF PA0875,
      WA_PA0875 TYPE PA0875,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PA0875> TYPE PA0875.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PA0875.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PA0875
  INTO TABLE IT_PA0875.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PA0875
*  INTO TABLE @DATA(IT_PA08752).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PA0875 INDEX 1 INTO DATA(WA_PA08752).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PA0875 ASSIGNING <PA0875>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PA0875>-MANDT = 1.
<PA0875>-PERNR = 1.
<PA0875>-SUBTY = 1.
<PA0875>-OBJPS = 1.
<PA0875>-SPRPS = 1.
ENDLOOP.

LOOP AT IT_PA0875 INTO WA_PA0875.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PA0875-ENDDA, sy-vline,
WA_PA0875-BEGDA, sy-vline,
WA_PA0875-SEQNR, sy-vline,
WA_PA0875-AEDTM, sy-vline,
WA_PA0875-UNAME, sy-vline,
WA_PA0875-HISTO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PA0875 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PA0875 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PA0875 INTO WA_PA0875. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field NRACT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PA0875-NRACT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PA0875-NRACT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LOC CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PA0875-LOC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PA0875-LOC.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field NRJUZ CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PA0875-NRJUZ IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PA0875-NRJUZ.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field NRSEC CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PA0875-NRSEC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PA0875-NRSEC.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PA0875_STR,
MANDT TYPE STRING,
PERNR TYPE STRING,
SUBTY TYPE STRING,
OBJPS TYPE STRING,
SPRPS TYPE STRING,
ENDDA TYPE STRING,
BEGDA TYPE STRING,
SEQNR TYPE STRING,
AEDTM TYPE STRING,
UNAME TYPE STRING,
HISTO TYPE STRING,
ITXEX TYPE STRING,
REFEX TYPE STRING,
ORDEX TYPE STRING,
ITBLD TYPE STRING,
PREAS TYPE STRING,
FLAG1 TYPE STRING,
FLAG2 TYPE STRING,
FLAG3 TYPE STRING,
FLAG4 TYPE STRING,
RESE1 TYPE STRING,
RESE2 TYPE STRING,
GRPVL TYPE STRING,
FAMSA TYPE STRING,
OBJ21 TYPE STRING,
CDEVT TYPE STRING,
FEEVT TYPE STRING,
FEDOC TYPE STRING,
TOMO TYPE STRING,
FOLIO TYPE STRING,
NRACT TYPE STRING,
PAIS TYPE STRING,
PROV TYPE STRING,
LOC TYPE STRING,
COMUN TYPE STRING,
TRBUN TYPE STRING,
NRJUZ TYPE STRING,
NRSEC TYPE STRING,
TXTDJ TYPE STRING,
CDDOC TYPE STRING,
CDDEX TYPE STRING,END OF T_EKKO_STR. DATA: WA_PA0875_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PA0875_STR-MANDT sy-vline
WA_PA0875_STR-PERNR sy-vline
WA_PA0875_STR-SUBTY sy-vline
WA_PA0875_STR-OBJPS sy-vline
WA_PA0875_STR-SPRPS sy-vline
WA_PA0875_STR-ENDDA sy-vline
WA_PA0875_STR-BEGDA sy-vline
WA_PA0875_STR-SEQNR sy-vline
WA_PA0875_STR-AEDTM sy-vline
WA_PA0875_STR-UNAME sy-vline
WA_PA0875_STR-HISTO sy-vline
WA_PA0875_STR-ITXEX sy-vline
WA_PA0875_STR-REFEX sy-vline
WA_PA0875_STR-ORDEX sy-vline
WA_PA0875_STR-ITBLD sy-vline
WA_PA0875_STR-PREAS sy-vline
WA_PA0875_STR-FLAG1 sy-vline
WA_PA0875_STR-FLAG2 sy-vline
WA_PA0875_STR-FLAG3 sy-vline
WA_PA0875_STR-FLAG4 sy-vline
WA_PA0875_STR-RESE1 sy-vline
WA_PA0875_STR-RESE2 sy-vline
WA_PA0875_STR-GRPVL sy-vline
WA_PA0875_STR-FAMSA sy-vline
WA_PA0875_STR-OBJ21 sy-vline
WA_PA0875_STR-CDEVT sy-vline
WA_PA0875_STR-FEEVT sy-vline
WA_PA0875_STR-FEDOC sy-vline
WA_PA0875_STR-TOMO sy-vline
WA_PA0875_STR-FOLIO sy-vline
WA_PA0875_STR-NRACT sy-vline
WA_PA0875_STR-PAIS sy-vline
WA_PA0875_STR-PROV sy-vline
WA_PA0875_STR-LOC sy-vline
WA_PA0875_STR-COMUN sy-vline
WA_PA0875_STR-TRBUN sy-vline
WA_PA0875_STR-NRJUZ sy-vline
WA_PA0875_STR-NRSEC sy-vline
WA_PA0875_STR-TXTDJ sy-vline
WA_PA0875_STR-CDDOC sy-vline
WA_PA0875_STR-CDDEX sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.