ABAP Select data from SAP table PA0707 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PA0707 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PA0707. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PA0707 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PA0707 TYPE STANDARD TABLE OF PA0707,
      WA_PA0707 TYPE PA0707,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PA0707> TYPE PA0707.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PA0707.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PA0707
  INTO TABLE IT_PA0707.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PA0707
*  INTO TABLE @DATA(IT_PA07072).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PA0707 INDEX 1 INTO DATA(WA_PA07072).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PA0707 ASSIGNING <PA0707>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PA0707>-MANDT = 1.
<PA0707>-PERNR = 1.
<PA0707>-SUBTY = 1.
<PA0707>-OBJPS = 1.
<PA0707>-SPRPS = 1.
ENDLOOP.

LOOP AT IT_PA0707 INTO WA_PA0707.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PA0707-ENDDA, sy-vline,
WA_PA0707-BEGDA, sy-vline,
WA_PA0707-SEQNR, sy-vline,
WA_PA0707-AEDTM, sy-vline,
WA_PA0707-UNAME, sy-vline,
WA_PA0707-HISTO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PA0707 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PA0707 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PA0707 INTO WA_PA0707. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PA0707_STR,
MANDT TYPE STRING,
PERNR TYPE STRING,
SUBTY TYPE STRING,
OBJPS TYPE STRING,
SPRPS TYPE STRING,
ENDDA TYPE STRING,
BEGDA TYPE STRING,
SEQNR TYPE STRING,
AEDTM TYPE STRING,
UNAME TYPE STRING,
HISTO TYPE STRING,
ITXEX TYPE STRING,
REFEX TYPE STRING,
ORDEX TYPE STRING,
ITBLD TYPE STRING,
PREAS TYPE STRING,
FLAG1 TYPE STRING,
FLAG2 TYPE STRING,
FLAG3 TYPE STRING,
FLAG4 TYPE STRING,
RESE1 TYPE STRING,
RESE2 TYPE STRING,
GRPVL TYPE STRING,
CURR_FLUC TYPE STRING,
CURR_PRCNT TYPE STRING,
STABLE_CUR TYPE STRING,
ACTIVATION_DATE TYPE STRING,
CATTYP01 TYPE STRING,
DD_HOM01 TYPE STRING,
DD_HOT01 TYPE STRING,
CATTYP02 TYPE STRING,
DD_HOM02 TYPE STRING,
DD_HOT02 TYPE STRING,
CATTYP03 TYPE STRING,
DD_HOM03 TYPE STRING,
DD_HOT03 TYPE STRING,
CATTYP04 TYPE STRING,
DD_HOM04 TYPE STRING,
DD_HOT04 TYPE STRING,
CATTYP05 TYPE STRING,
DD_HOM05 TYPE STRING,
DD_HOT05 TYPE STRING,
CATTYP06 TYPE STRING,
DD_HOM06 TYPE STRING,
DD_HOT06 TYPE STRING,
CATTYP07 TYPE STRING,
DD_HOM07 TYPE STRING,
DD_HOT07 TYPE STRING,
CATTYP08 TYPE STRING,
DD_HOM08 TYPE STRING,
DD_HOT08 TYPE STRING,
CATTYP09 TYPE STRING,
DD_HOM09 TYPE STRING,
DD_HOT09 TYPE STRING,
CATTYP10 TYPE STRING,
DD_HOM10 TYPE STRING,
DD_HOT10 TYPE STRING,
CATTYP11 TYPE STRING,
DD_HOM11 TYPE STRING,
DD_HOT11 TYPE STRING,
CATTYP12 TYPE STRING,
DD_HOM12 TYPE STRING,
DD_HOT12 TYPE STRING,
CATTYP13 TYPE STRING,
DD_HOM13 TYPE STRING,
DD_HOT13 TYPE STRING,
CATTYP14 TYPE STRING,
DD_HOM14 TYPE STRING,
DD_HOT14 TYPE STRING,
CATTYP15 TYPE STRING,
DD_HOM15 TYPE STRING,
DD_HOT15 TYPE STRING,
CATTYP16 TYPE STRING,
DD_HOM16 TYPE STRING,
DD_HOT16 TYPE STRING,
CATTYP17 TYPE STRING,
DD_HOM17 TYPE STRING,
DD_HOT17 TYPE STRING,
CATTYP18 TYPE STRING,
DD_HOM18 TYPE STRING,
DD_HOT18 TYPE STRING,
CATTYP19 TYPE STRING,
DD_HOM19 TYPE STRING,
DD_HOT19 TYPE STRING,
CATTYP20 TYPE STRING,
DD_HOM20 TYPE STRING,
DD_HOT20 TYPE STRING,END OF T_EKKO_STR. DATA: WA_PA0707_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PA0707_STR-MANDT sy-vline
WA_PA0707_STR-PERNR sy-vline
WA_PA0707_STR-SUBTY sy-vline
WA_PA0707_STR-OBJPS sy-vline
WA_PA0707_STR-SPRPS sy-vline
WA_PA0707_STR-ENDDA sy-vline
WA_PA0707_STR-BEGDA sy-vline
WA_PA0707_STR-SEQNR sy-vline
WA_PA0707_STR-AEDTM sy-vline
WA_PA0707_STR-UNAME sy-vline
WA_PA0707_STR-HISTO sy-vline
WA_PA0707_STR-ITXEX sy-vline
WA_PA0707_STR-REFEX sy-vline
WA_PA0707_STR-ORDEX sy-vline
WA_PA0707_STR-ITBLD sy-vline
WA_PA0707_STR-PREAS sy-vline
WA_PA0707_STR-FLAG1 sy-vline
WA_PA0707_STR-FLAG2 sy-vline
WA_PA0707_STR-FLAG3 sy-vline
WA_PA0707_STR-FLAG4 sy-vline
WA_PA0707_STR-RESE1 sy-vline
WA_PA0707_STR-RESE2 sy-vline
WA_PA0707_STR-GRPVL sy-vline
WA_PA0707_STR-CURR_FLUC sy-vline
WA_PA0707_STR-CURR_PRCNT sy-vline
WA_PA0707_STR-STABLE_CUR sy-vline
WA_PA0707_STR-ACTIVATION_DATE sy-vline
WA_PA0707_STR-CATTYP01 sy-vline
WA_PA0707_STR-DD_HOM01 sy-vline
WA_PA0707_STR-DD_HOT01 sy-vline
WA_PA0707_STR-CATTYP02 sy-vline
WA_PA0707_STR-DD_HOM02 sy-vline
WA_PA0707_STR-DD_HOT02 sy-vline
WA_PA0707_STR-CATTYP03 sy-vline
WA_PA0707_STR-DD_HOM03 sy-vline
WA_PA0707_STR-DD_HOT03 sy-vline
WA_PA0707_STR-CATTYP04 sy-vline
WA_PA0707_STR-DD_HOM04 sy-vline
WA_PA0707_STR-DD_HOT04 sy-vline
WA_PA0707_STR-CATTYP05 sy-vline
WA_PA0707_STR-DD_HOM05 sy-vline
WA_PA0707_STR-DD_HOT05 sy-vline
WA_PA0707_STR-CATTYP06 sy-vline
WA_PA0707_STR-DD_HOM06 sy-vline
WA_PA0707_STR-DD_HOT06 sy-vline
WA_PA0707_STR-CATTYP07 sy-vline
WA_PA0707_STR-DD_HOM07 sy-vline
WA_PA0707_STR-DD_HOT07 sy-vline
WA_PA0707_STR-CATTYP08 sy-vline
WA_PA0707_STR-DD_HOM08 sy-vline
WA_PA0707_STR-DD_HOT08 sy-vline
WA_PA0707_STR-CATTYP09 sy-vline
WA_PA0707_STR-DD_HOM09 sy-vline
WA_PA0707_STR-DD_HOT09 sy-vline
WA_PA0707_STR-CATTYP10 sy-vline
WA_PA0707_STR-DD_HOM10 sy-vline
WA_PA0707_STR-DD_HOT10 sy-vline
WA_PA0707_STR-CATTYP11 sy-vline
WA_PA0707_STR-DD_HOM11 sy-vline
WA_PA0707_STR-DD_HOT11 sy-vline
WA_PA0707_STR-CATTYP12 sy-vline
WA_PA0707_STR-DD_HOM12 sy-vline
WA_PA0707_STR-DD_HOT12 sy-vline
WA_PA0707_STR-CATTYP13 sy-vline
WA_PA0707_STR-DD_HOM13 sy-vline
WA_PA0707_STR-DD_HOT13 sy-vline
WA_PA0707_STR-CATTYP14 sy-vline
WA_PA0707_STR-DD_HOM14 sy-vline
WA_PA0707_STR-DD_HOT14 sy-vline
WA_PA0707_STR-CATTYP15 sy-vline
WA_PA0707_STR-DD_HOM15 sy-vline
WA_PA0707_STR-DD_HOT15 sy-vline
WA_PA0707_STR-CATTYP16 sy-vline
WA_PA0707_STR-DD_HOM16 sy-vline
WA_PA0707_STR-DD_HOT16 sy-vline
WA_PA0707_STR-CATTYP17 sy-vline
WA_PA0707_STR-DD_HOM17 sy-vline
WA_PA0707_STR-DD_HOT17 sy-vline
WA_PA0707_STR-CATTYP18 sy-vline
WA_PA0707_STR-DD_HOM18 sy-vline
WA_PA0707_STR-DD_HOT18 sy-vline
WA_PA0707_STR-CATTYP19 sy-vline
WA_PA0707_STR-DD_HOM19 sy-vline
WA_PA0707_STR-DD_HOT19 sy-vline
WA_PA0707_STR-CATTYP20 sy-vline
WA_PA0707_STR-DD_HOM20 sy-vline
WA_PA0707_STR-DD_HOT20 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.