ABAP Select data from SAP table PA0564 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PA0564 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PA0564. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PA0564 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PA0564 TYPE STANDARD TABLE OF PA0564,
      WA_PA0564 TYPE PA0564,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PA0564> TYPE PA0564.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PA0564.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PA0564
  INTO TABLE IT_PA0564.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PA0564
*  INTO TABLE @DATA(IT_PA05642).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PA0564 INDEX 1 INTO DATA(WA_PA05642).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PA0564 ASSIGNING <PA0564>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PA0564>-MANDT = 1.
<PA0564>-PERNR = 1.
<PA0564>-SUBTY = 1.
<PA0564>-OBJPS = 1.
<PA0564>-SPRPS = 1.
ENDLOOP.

LOOP AT IT_PA0564 INTO WA_PA0564.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PA0564-ENDDA, sy-vline,
WA_PA0564-BEGDA, sy-vline,
WA_PA0564-SEQNR, sy-vline,
WA_PA0564-AEDTM, sy-vline,
WA_PA0564-UNAME, sy-vline,
WA_PA0564-HISTO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PA0564 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PA0564 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PA0564 INTO WA_PA0564. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PA0564_STR,
MANDT TYPE STRING,
PERNR TYPE STRING,
SUBTY TYPE STRING,
OBJPS TYPE STRING,
SPRPS TYPE STRING,
ENDDA TYPE STRING,
BEGDA TYPE STRING,
SEQNR TYPE STRING,
AEDTM TYPE STRING,
UNAME TYPE STRING,
HISTO TYPE STRING,
ITXEX TYPE STRING,
REFEX TYPE STRING,
ORDEX TYPE STRING,
ITBLD TYPE STRING,
PREAS TYPE STRING,
FLAG1 TYPE STRING,
FLAG2 TYPE STRING,
FLAG3 TYPE STRING,
FLAG4 TYPE STRING,
RESE1 TYPE STRING,
RESE2 TYPE STRING,
GRPVL TYPE STRING,
MUNCO TYPE STRING,
VARGU TYPE STRING,
EETYP TYPE STRING,
DEDPE TYPE STRING,
DEDFA TYPE STRING,
PRSAL TYPE STRING,
PRTAX TYPE STRING,
DEDTO TYPE STRING,
NOINV TYPE STRING,
INVRA TYPE STRING,
INVDR TYPE STRING,
MRGOD TYPE STRING,
MRMJE TYPE STRING,
MRDAN TYPE STRING,
DEDBA TYPE STRING,
REGOF TYPE STRING,
ETYPE TYPE STRING,
SILEV TYPE STRING,
EEPEC TYPE STRING,
EEPEI TYPE STRING,
ERPEC TYPE STRING,
ERPEI TYPE STRING,
ERHEC TYPE STRING,
ERHEI TYPE STRING,
ERHDC TYPE STRING,
EREMC TYPE STRING,
EREMI TYPE STRING,
ERINC TYPE STRING,
ERINI TYPE STRING,
ERTAC TYPE STRING,
KATEG TYPE STRING,
TAX TYPE STRING,
FCTTX TYPE STRING,
NHTYP TYPE STRING,
NEREZ TYPE STRING,
DRREZ TYPE STRING,
NOSTX TYPE STRING,
ACNTR TYPE STRING,END OF T_EKKO_STR. DATA: WA_PA0564_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PA0564_STR-MANDT sy-vline
WA_PA0564_STR-PERNR sy-vline
WA_PA0564_STR-SUBTY sy-vline
WA_PA0564_STR-OBJPS sy-vline
WA_PA0564_STR-SPRPS sy-vline
WA_PA0564_STR-ENDDA sy-vline
WA_PA0564_STR-BEGDA sy-vline
WA_PA0564_STR-SEQNR sy-vline
WA_PA0564_STR-AEDTM sy-vline
WA_PA0564_STR-UNAME sy-vline
WA_PA0564_STR-HISTO sy-vline
WA_PA0564_STR-ITXEX sy-vline
WA_PA0564_STR-REFEX sy-vline
WA_PA0564_STR-ORDEX sy-vline
WA_PA0564_STR-ITBLD sy-vline
WA_PA0564_STR-PREAS sy-vline
WA_PA0564_STR-FLAG1 sy-vline
WA_PA0564_STR-FLAG2 sy-vline
WA_PA0564_STR-FLAG3 sy-vline
WA_PA0564_STR-FLAG4 sy-vline
WA_PA0564_STR-RESE1 sy-vline
WA_PA0564_STR-RESE2 sy-vline
WA_PA0564_STR-GRPVL sy-vline
WA_PA0564_STR-MUNCO sy-vline
WA_PA0564_STR-VARGU sy-vline
WA_PA0564_STR-EETYP sy-vline
WA_PA0564_STR-DEDPE sy-vline
WA_PA0564_STR-DEDFA sy-vline
WA_PA0564_STR-PRSAL sy-vline
WA_PA0564_STR-PRTAX sy-vline
WA_PA0564_STR-DEDTO sy-vline
WA_PA0564_STR-NOINV sy-vline
WA_PA0564_STR-INVRA sy-vline
WA_PA0564_STR-INVDR sy-vline
WA_PA0564_STR-MRGOD sy-vline
WA_PA0564_STR-MRMJE sy-vline
WA_PA0564_STR-MRDAN sy-vline
WA_PA0564_STR-DEDBA sy-vline
WA_PA0564_STR-REGOF sy-vline
WA_PA0564_STR-ETYPE sy-vline
WA_PA0564_STR-SILEV sy-vline
WA_PA0564_STR-EEPEC sy-vline
WA_PA0564_STR-EEPEI sy-vline
WA_PA0564_STR-ERPEC sy-vline
WA_PA0564_STR-ERPEI sy-vline
WA_PA0564_STR-ERHEC sy-vline
WA_PA0564_STR-ERHEI sy-vline
WA_PA0564_STR-ERHDC sy-vline
WA_PA0564_STR-EREMC sy-vline
WA_PA0564_STR-EREMI sy-vline
WA_PA0564_STR-ERINC sy-vline
WA_PA0564_STR-ERINI sy-vline
WA_PA0564_STR-ERTAC sy-vline
WA_PA0564_STR-KATEG sy-vline
WA_PA0564_STR-TAX sy-vline
WA_PA0564_STR-FCTTX sy-vline
WA_PA0564_STR-NHTYP sy-vline
WA_PA0564_STR-NEREZ sy-vline
WA_PA0564_STR-DRREZ sy-vline
WA_PA0564_STR-NOSTX sy-vline
WA_PA0564_STR-ACNTR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.