ABAP Select data from SAP table PA0307 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PA0307 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PA0307. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PA0307 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PA0307 TYPE STANDARD TABLE OF PA0307,
      WA_PA0307 TYPE PA0307,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PA0307> TYPE PA0307.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PA0307.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PA0307
  INTO TABLE IT_PA0307.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PA0307
*  INTO TABLE @DATA(IT_PA03072).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PA0307 INDEX 1 INTO DATA(WA_PA03072).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PA0307 ASSIGNING <PA0307>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PA0307>-MANDT = 1.
<PA0307>-PERNR = 1.
<PA0307>-SUBTY = 1.
<PA0307>-OBJPS = 1.
<PA0307>-SPRPS = 1.
ENDLOOP.

LOOP AT IT_PA0307 INTO WA_PA0307.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PA0307-ENDDA, sy-vline,
WA_PA0307-BEGDA, sy-vline,
WA_PA0307-SEQNR, sy-vline,
WA_PA0307-AEDTM, sy-vline,
WA_PA0307-UNAME, sy-vline,
WA_PA0307-HISTO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PA0307 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PA0307 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PA0307 INTO WA_PA0307. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PA0307_STR,
MANDT TYPE STRING,
PERNR TYPE STRING,
SUBTY TYPE STRING,
OBJPS TYPE STRING,
SPRPS TYPE STRING,
ENDDA TYPE STRING,
BEGDA TYPE STRING,
SEQNR TYPE STRING,
AEDTM TYPE STRING,
UNAME TYPE STRING,
HISTO TYPE STRING,
ITXEX TYPE STRING,
REFEX TYPE STRING,
ORDEX TYPE STRING,
ITBLD TYPE STRING,
PREAS TYPE STRING,
FLAG1 TYPE STRING,
FLAG2 TYPE STRING,
FLAG3 TYPE STRING,
FLAG4 TYPE STRING,
RESE1 TYPE STRING,
RESE2 TYPE STRING,
GRPVL TYPE STRING,
LGA_001 TYPE STRING,
BET_001 TYPE STRING,
LGA_002 TYPE STRING,
BET_002 TYPE STRING,
LGA_003 TYPE STRING,
BET_003 TYPE STRING,
LGA_004 TYPE STRING,
BET_004 TYPE STRING,
LGA_005 TYPE STRING,
BET_005 TYPE STRING,
LGA_006 TYPE STRING,
BET_006 TYPE STRING,
LGA_007 TYPE STRING,
BET_007 TYPE STRING,
LGA_008 TYPE STRING,
BET_008 TYPE STRING,
LGA_009 TYPE STRING,
BET_009 TYPE STRING,
LGA_010 TYPE STRING,
BET_010 TYPE STRING,
LGA_011 TYPE STRING,
BET_011 TYPE STRING,
LGA_012 TYPE STRING,
BET_012 TYPE STRING,
LGA_013 TYPE STRING,
BET_013 TYPE STRING,
LGA_014 TYPE STRING,
BET_014 TYPE STRING,
LGA_015 TYPE STRING,
BET_015 TYPE STRING,
LGA_016 TYPE STRING,
BET_016 TYPE STRING,
LGA_017 TYPE STRING,
BET_017 TYPE STRING,
LGA_018 TYPE STRING,
BET_018 TYPE STRING,
LGA_019 TYPE STRING,
BET_019 TYPE STRING,
LGA_020 TYPE STRING,
BET_020 TYPE STRING,
LGA_021 TYPE STRING,
BET_021 TYPE STRING,
LGA_022 TYPE STRING,
BET_022 TYPE STRING,
LGA_023 TYPE STRING,
BET_023 TYPE STRING,
LGA_024 TYPE STRING,
BET_024 TYPE STRING,
LGA_025 TYPE STRING,
BET_025 TYPE STRING,
LGA_026 TYPE STRING,
BET_026 TYPE STRING,
LGA_027 TYPE STRING,
BET_027 TYPE STRING,
LGA_028 TYPE STRING,
BET_028 TYPE STRING,
LGA_029 TYPE STRING,
BET_029 TYPE STRING,
LGA_030 TYPE STRING,
BET_030 TYPE STRING,
LGA_031 TYPE STRING,
BET_031 TYPE STRING,
LGA_032 TYPE STRING,
BET_032 TYPE STRING,
LGA_033 TYPE STRING,
BET_033 TYPE STRING,
LGA_034 TYPE STRING,
BET_034 TYPE STRING,
LGA_035 TYPE STRING,
BET_035 TYPE STRING,
LGA_036 TYPE STRING,
BET_036 TYPE STRING,
LGA_037 TYPE STRING,
BET_037 TYPE STRING,
LGA_038 TYPE STRING,
BET_038 TYPE STRING,
LGA_039 TYPE STRING,
BET_039 TYPE STRING,
LGA_040 TYPE STRING,
BET_040 TYPE STRING,
LGA_051 TYPE STRING,
SZO_051 TYPE STRING,
LGA_052 TYPE STRING,
SZO_052 TYPE STRING,
LGA_053 TYPE STRING,
SZO_053 TYPE STRING,
LGA_054 TYPE STRING,
SZO_054 TYPE STRING,
LGA_055 TYPE STRING,
SZO_055 TYPE STRING,
LGA_056 TYPE STRING,
SZO_056 TYPE STRING,
LGA_057 TYPE STRING,
SZO_057 TYPE STRING,
LGA_058 TYPE STRING,
SZO_058 TYPE STRING,
LGA_059 TYPE STRING,
SZO_059 TYPE STRING,
LGA_060 TYPE STRING,
SZO_060 TYPE STRING,
LGA_06A TYPE STRING,
SZO_06A TYPE STRING,
LGA_06B TYPE STRING,
SZO_06B TYPE STRING,
LGA_06C TYPE STRING,
SZO_06C TYPE STRING,
LGA_06D TYPE STRING,
SZO_06D TYPE STRING,
LGA_06E TYPE STRING,
SZO_06E TYPE STRING,
LGA_06F TYPE STRING,
SZO_06F TYPE STRING,
LGA_061 TYPE STRING,
ANZ_061 TYPE STRING,
EIN_061 TYPE STRING,
LGA_062 TYPE STRING,
ANZ_062 TYPE STRING,
EIN_062 TYPE STRING,
LGA_063 TYPE STRING,
ANZ_063 TYPE STRING,
EIN_063 TYPE STRING,
LGA_064 TYPE STRING,
ANZ_064 TYPE STRING,
EIN_064 TYPE STRING,
LGA_065 TYPE STRING,
ANZ_065 TYPE STRING,
EIN_065 TYPE STRING,
LGA_066 TYPE STRING,
ANZ_066 TYPE STRING,
EIN_066 TYPE STRING,
LGA_071 TYPE STRING,
FBC_071 TYPE STRING,
LGA_072 TYPE STRING,
FBC_072 TYPE STRING,
LGA_073 TYPE STRING,
FBC_073 TYPE STRING,
LGA_074 TYPE STRING,
FBC_074 TYPE STRING,
LGA_075 TYPE STRING,
FBC_075 TYPE STRING,
LGA_076 TYPE STRING,
FBC_076 TYPE STRING,
WAERS TYPE STRING,END OF T_EKKO_STR. DATA: WA_PA0307_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PA0307_STR-MANDT sy-vline
WA_PA0307_STR-PERNR sy-vline
WA_PA0307_STR-SUBTY sy-vline
WA_PA0307_STR-OBJPS sy-vline
WA_PA0307_STR-SPRPS sy-vline
WA_PA0307_STR-ENDDA sy-vline
WA_PA0307_STR-BEGDA sy-vline
WA_PA0307_STR-SEQNR sy-vline
WA_PA0307_STR-AEDTM sy-vline
WA_PA0307_STR-UNAME sy-vline
WA_PA0307_STR-HISTO sy-vline
WA_PA0307_STR-ITXEX sy-vline
WA_PA0307_STR-REFEX sy-vline
WA_PA0307_STR-ORDEX sy-vline
WA_PA0307_STR-ITBLD sy-vline
WA_PA0307_STR-PREAS sy-vline
WA_PA0307_STR-FLAG1 sy-vline
WA_PA0307_STR-FLAG2 sy-vline
WA_PA0307_STR-FLAG3 sy-vline
WA_PA0307_STR-FLAG4 sy-vline
WA_PA0307_STR-RESE1 sy-vline
WA_PA0307_STR-RESE2 sy-vline
WA_PA0307_STR-GRPVL sy-vline
WA_PA0307_STR-LGA_001 sy-vline
WA_PA0307_STR-BET_001 sy-vline
WA_PA0307_STR-LGA_002 sy-vline
WA_PA0307_STR-BET_002 sy-vline
WA_PA0307_STR-LGA_003 sy-vline
WA_PA0307_STR-BET_003 sy-vline
WA_PA0307_STR-LGA_004 sy-vline
WA_PA0307_STR-BET_004 sy-vline
WA_PA0307_STR-LGA_005 sy-vline
WA_PA0307_STR-BET_005 sy-vline
WA_PA0307_STR-LGA_006 sy-vline
WA_PA0307_STR-BET_006 sy-vline
WA_PA0307_STR-LGA_007 sy-vline
WA_PA0307_STR-BET_007 sy-vline
WA_PA0307_STR-LGA_008 sy-vline
WA_PA0307_STR-BET_008 sy-vline
WA_PA0307_STR-LGA_009 sy-vline
WA_PA0307_STR-BET_009 sy-vline
WA_PA0307_STR-LGA_010 sy-vline
WA_PA0307_STR-BET_010 sy-vline
WA_PA0307_STR-LGA_011 sy-vline
WA_PA0307_STR-BET_011 sy-vline
WA_PA0307_STR-LGA_012 sy-vline
WA_PA0307_STR-BET_012 sy-vline
WA_PA0307_STR-LGA_013 sy-vline
WA_PA0307_STR-BET_013 sy-vline
WA_PA0307_STR-LGA_014 sy-vline
WA_PA0307_STR-BET_014 sy-vline
WA_PA0307_STR-LGA_015 sy-vline
WA_PA0307_STR-BET_015 sy-vline
WA_PA0307_STR-LGA_016 sy-vline
WA_PA0307_STR-BET_016 sy-vline
WA_PA0307_STR-LGA_017 sy-vline
WA_PA0307_STR-BET_017 sy-vline
WA_PA0307_STR-LGA_018 sy-vline
WA_PA0307_STR-BET_018 sy-vline
WA_PA0307_STR-LGA_019 sy-vline
WA_PA0307_STR-BET_019 sy-vline
WA_PA0307_STR-LGA_020 sy-vline
WA_PA0307_STR-BET_020 sy-vline
WA_PA0307_STR-LGA_021 sy-vline
WA_PA0307_STR-BET_021 sy-vline
WA_PA0307_STR-LGA_022 sy-vline
WA_PA0307_STR-BET_022 sy-vline
WA_PA0307_STR-LGA_023 sy-vline
WA_PA0307_STR-BET_023 sy-vline
WA_PA0307_STR-LGA_024 sy-vline
WA_PA0307_STR-BET_024 sy-vline
WA_PA0307_STR-LGA_025 sy-vline
WA_PA0307_STR-BET_025 sy-vline
WA_PA0307_STR-LGA_026 sy-vline
WA_PA0307_STR-BET_026 sy-vline
WA_PA0307_STR-LGA_027 sy-vline
WA_PA0307_STR-BET_027 sy-vline
WA_PA0307_STR-LGA_028 sy-vline
WA_PA0307_STR-BET_028 sy-vline
WA_PA0307_STR-LGA_029 sy-vline
WA_PA0307_STR-BET_029 sy-vline
WA_PA0307_STR-LGA_030 sy-vline
WA_PA0307_STR-BET_030 sy-vline
WA_PA0307_STR-LGA_031 sy-vline
WA_PA0307_STR-BET_031 sy-vline
WA_PA0307_STR-LGA_032 sy-vline
WA_PA0307_STR-BET_032 sy-vline
WA_PA0307_STR-LGA_033 sy-vline
WA_PA0307_STR-BET_033 sy-vline
WA_PA0307_STR-LGA_034 sy-vline
WA_PA0307_STR-BET_034 sy-vline
WA_PA0307_STR-LGA_035 sy-vline
WA_PA0307_STR-BET_035 sy-vline
WA_PA0307_STR-LGA_036 sy-vline
WA_PA0307_STR-BET_036 sy-vline
WA_PA0307_STR-LGA_037 sy-vline
WA_PA0307_STR-BET_037 sy-vline
WA_PA0307_STR-LGA_038 sy-vline
WA_PA0307_STR-BET_038 sy-vline
WA_PA0307_STR-LGA_039 sy-vline
WA_PA0307_STR-BET_039 sy-vline
WA_PA0307_STR-LGA_040 sy-vline
WA_PA0307_STR-BET_040 sy-vline
WA_PA0307_STR-LGA_051 sy-vline
WA_PA0307_STR-SZO_051 sy-vline
WA_PA0307_STR-LGA_052 sy-vline
WA_PA0307_STR-SZO_052 sy-vline
WA_PA0307_STR-LGA_053 sy-vline
WA_PA0307_STR-SZO_053 sy-vline
WA_PA0307_STR-LGA_054 sy-vline
WA_PA0307_STR-SZO_054 sy-vline
WA_PA0307_STR-LGA_055 sy-vline
WA_PA0307_STR-SZO_055 sy-vline
WA_PA0307_STR-LGA_056 sy-vline
WA_PA0307_STR-SZO_056 sy-vline
WA_PA0307_STR-LGA_057 sy-vline
WA_PA0307_STR-SZO_057 sy-vline
WA_PA0307_STR-LGA_058 sy-vline
WA_PA0307_STR-SZO_058 sy-vline
WA_PA0307_STR-LGA_059 sy-vline
WA_PA0307_STR-SZO_059 sy-vline
WA_PA0307_STR-LGA_060 sy-vline
WA_PA0307_STR-SZO_060 sy-vline
WA_PA0307_STR-LGA_06A sy-vline
WA_PA0307_STR-SZO_06A sy-vline
WA_PA0307_STR-LGA_06B sy-vline
WA_PA0307_STR-SZO_06B sy-vline
WA_PA0307_STR-LGA_06C sy-vline
WA_PA0307_STR-SZO_06C sy-vline
WA_PA0307_STR-LGA_06D sy-vline
WA_PA0307_STR-SZO_06D sy-vline
WA_PA0307_STR-LGA_06E sy-vline
WA_PA0307_STR-SZO_06E sy-vline
WA_PA0307_STR-LGA_06F sy-vline
WA_PA0307_STR-SZO_06F sy-vline
WA_PA0307_STR-LGA_061 sy-vline
WA_PA0307_STR-ANZ_061 sy-vline
WA_PA0307_STR-EIN_061 sy-vline
WA_PA0307_STR-LGA_062 sy-vline
WA_PA0307_STR-ANZ_062 sy-vline
WA_PA0307_STR-EIN_062 sy-vline
WA_PA0307_STR-LGA_063 sy-vline
WA_PA0307_STR-ANZ_063 sy-vline
WA_PA0307_STR-EIN_063 sy-vline
WA_PA0307_STR-LGA_064 sy-vline
WA_PA0307_STR-ANZ_064 sy-vline
WA_PA0307_STR-EIN_064 sy-vline
WA_PA0307_STR-LGA_065 sy-vline
WA_PA0307_STR-ANZ_065 sy-vline
WA_PA0307_STR-EIN_065 sy-vline
WA_PA0307_STR-LGA_066 sy-vline
WA_PA0307_STR-ANZ_066 sy-vline
WA_PA0307_STR-EIN_066 sy-vline
WA_PA0307_STR-LGA_071 sy-vline
WA_PA0307_STR-FBC_071 sy-vline
WA_PA0307_STR-LGA_072 sy-vline
WA_PA0307_STR-FBC_072 sy-vline
WA_PA0307_STR-LGA_073 sy-vline
WA_PA0307_STR-FBC_073 sy-vline
WA_PA0307_STR-LGA_074 sy-vline
WA_PA0307_STR-FBC_074 sy-vline
WA_PA0307_STR-LGA_075 sy-vline
WA_PA0307_STR-FBC_075 sy-vline
WA_PA0307_STR-LGA_076 sy-vline
WA_PA0307_STR-FBC_076 sy-vline
WA_PA0307_STR-WAERS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.