ABAP Select data from SAP table PA0265 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PA0265 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PA0265. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PA0265 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PA0265 TYPE STANDARD TABLE OF PA0265,
      WA_PA0265 TYPE PA0265,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PA0265> TYPE PA0265.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PA0265.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PA0265
  INTO TABLE IT_PA0265.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PA0265
*  INTO TABLE @DATA(IT_PA02652).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PA0265 INDEX 1 INTO DATA(WA_PA02652).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PA0265 ASSIGNING <PA0265>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PA0265>-MANDT = 1.
<PA0265>-PERNR = 1.
<PA0265>-SUBTY = 1.
<PA0265>-OBJPS = 1.
<PA0265>-SPRPS = 1.
ENDLOOP.

LOOP AT IT_PA0265 INTO WA_PA0265.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PA0265-ENDDA, sy-vline,
WA_PA0265-BEGDA, sy-vline,
WA_PA0265-SEQNR, sy-vline,
WA_PA0265-AEDTM, sy-vline,
WA_PA0265-UNAME, sy-vline,
WA_PA0265-HISTO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PA0265 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PA0265 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PA0265 INTO WA_PA0265. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PA0265_STR,
MANDT TYPE STRING,
PERNR TYPE STRING,
SUBTY TYPE STRING,
OBJPS TYPE STRING,
SPRPS TYPE STRING,
ENDDA TYPE STRING,
BEGDA TYPE STRING,
SEQNR TYPE STRING,
AEDTM TYPE STRING,
UNAME TYPE STRING,
HISTO TYPE STRING,
ITXEX TYPE STRING,
REFEX TYPE STRING,
ORDEX TYPE STRING,
ITBLD TYPE STRING,
PREAS TYPE STRING,
FLAG1 TYPE STRING,
FLAG2 TYPE STRING,
FLAG3 TYPE STRING,
FLAG4 TYPE STRING,
RESE1 TYPE STRING,
RESE2 TYPE STRING,
GRPVL TYPE STRING,
BMMZW TYPE STRING,
AZMZW TYPE STRING,
ANSZW TYPE STRING,
SPGZW TYPE STRING,
URAUF TYPE STRING,
ANMNT TYPE STRING,
AZMUR TYPE STRING,
ANSUR TYPE STRING,
SPGUR TYPE STRING,
AMNGW TYPE STRING,
ZUWPF TYPE STRING,
DAUER TYPE STRING,
BEMSZ TYPE STRING,END OF T_EKKO_STR. DATA: WA_PA0265_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PA0265_STR-MANDT sy-vline
WA_PA0265_STR-PERNR sy-vline
WA_PA0265_STR-SUBTY sy-vline
WA_PA0265_STR-OBJPS sy-vline
WA_PA0265_STR-SPRPS sy-vline
WA_PA0265_STR-ENDDA sy-vline
WA_PA0265_STR-BEGDA sy-vline
WA_PA0265_STR-SEQNR sy-vline
WA_PA0265_STR-AEDTM sy-vline
WA_PA0265_STR-UNAME sy-vline
WA_PA0265_STR-HISTO sy-vline
WA_PA0265_STR-ITXEX sy-vline
WA_PA0265_STR-REFEX sy-vline
WA_PA0265_STR-ORDEX sy-vline
WA_PA0265_STR-ITBLD sy-vline
WA_PA0265_STR-PREAS sy-vline
WA_PA0265_STR-FLAG1 sy-vline
WA_PA0265_STR-FLAG2 sy-vline
WA_PA0265_STR-FLAG3 sy-vline
WA_PA0265_STR-FLAG4 sy-vline
WA_PA0265_STR-RESE1 sy-vline
WA_PA0265_STR-RESE2 sy-vline
WA_PA0265_STR-GRPVL sy-vline
WA_PA0265_STR-BMMZW sy-vline
WA_PA0265_STR-AZMZW sy-vline
WA_PA0265_STR-ANSZW sy-vline
WA_PA0265_STR-SPGZW sy-vline
WA_PA0265_STR-URAUF sy-vline
WA_PA0265_STR-ANMNT sy-vline
WA_PA0265_STR-AZMUR sy-vline
WA_PA0265_STR-ANSUR sy-vline
WA_PA0265_STR-SPGUR sy-vline
WA_PA0265_STR-AMNGW sy-vline
WA_PA0265_STR-ZUWPF sy-vline
WA_PA0265_STR-DAUER sy-vline
WA_PA0265_STR-BEMSZ sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.