ABAP Select data from SAP table PA0143 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PA0143 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PA0143. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PA0143 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PA0143 TYPE STANDARD TABLE OF PA0143,
      WA_PA0143 TYPE PA0143,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PA0143> TYPE PA0143.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PA0143.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PA0143
  INTO TABLE IT_PA0143.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PA0143
*  INTO TABLE @DATA(IT_PA01432).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PA0143 INDEX 1 INTO DATA(WA_PA01432).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PA0143 ASSIGNING <PA0143>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PA0143>-MANDT = 1.
<PA0143>-PERNR = 1.
<PA0143>-SUBTY = 1.
<PA0143>-OBJPS = 1.
<PA0143>-SPRPS = 1.
ENDLOOP.

LOOP AT IT_PA0143 INTO WA_PA0143.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PA0143-ENDDA, sy-vline,
WA_PA0143-BEGDA, sy-vline,
WA_PA0143-SEQNR, sy-vline,
WA_PA0143-AEDTM, sy-vline,
WA_PA0143-UNAME, sy-vline,
WA_PA0143-HISTO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PA0143 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PA0143 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PA0143 INTO WA_PA0143. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit GJAHR, internal->external for field DIVYR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_PA0143-DIVYR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PA0143-DIVYR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PA0143_STR,
MANDT TYPE STRING,
PERNR TYPE STRING,
SUBTY TYPE STRING,
OBJPS TYPE STRING,
SPRPS TYPE STRING,
ENDDA TYPE STRING,
BEGDA TYPE STRING,
SEQNR TYPE STRING,
AEDTM TYPE STRING,
UNAME TYPE STRING,
HISTO TYPE STRING,
ITXEX TYPE STRING,
REFEX TYPE STRING,
ORDEX TYPE STRING,
ITBLD TYPE STRING,
PREAS TYPE STRING,
FLAG1 TYPE STRING,
FLAG2 TYPE STRING,
FLAG3 TYPE STRING,
FLAG4 TYPE STRING,
RESE1 TYPE STRING,
RESE2 TYPE STRING,
GRPVL TYPE STRING,
INSID TYPE STRING,
INSCC TYPE STRING,
INSNR TYPE STRING,
INSMP TYPE STRING,
INSBP TYPE STRING,
CONDA TYPE STRING,
INSCT TYPE STRING,
INSPR TYPE STRING,
DVAMT TYPE STRING,
DIVYR TYPE STRING,
DIVMN TYPE STRING,END OF T_EKKO_STR. DATA: WA_PA0143_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PA0143_STR-MANDT sy-vline
WA_PA0143_STR-PERNR sy-vline
WA_PA0143_STR-SUBTY sy-vline
WA_PA0143_STR-OBJPS sy-vline
WA_PA0143_STR-SPRPS sy-vline
WA_PA0143_STR-ENDDA sy-vline
WA_PA0143_STR-BEGDA sy-vline
WA_PA0143_STR-SEQNR sy-vline
WA_PA0143_STR-AEDTM sy-vline
WA_PA0143_STR-UNAME sy-vline
WA_PA0143_STR-HISTO sy-vline
WA_PA0143_STR-ITXEX sy-vline
WA_PA0143_STR-REFEX sy-vline
WA_PA0143_STR-ORDEX sy-vline
WA_PA0143_STR-ITBLD sy-vline
WA_PA0143_STR-PREAS sy-vline
WA_PA0143_STR-FLAG1 sy-vline
WA_PA0143_STR-FLAG2 sy-vline
WA_PA0143_STR-FLAG3 sy-vline
WA_PA0143_STR-FLAG4 sy-vline
WA_PA0143_STR-RESE1 sy-vline
WA_PA0143_STR-RESE2 sy-vline
WA_PA0143_STR-GRPVL sy-vline
WA_PA0143_STR-INSID sy-vline
WA_PA0143_STR-INSCC sy-vline
WA_PA0143_STR-INSNR sy-vline
WA_PA0143_STR-INSMP sy-vline
WA_PA0143_STR-INSBP sy-vline
WA_PA0143_STR-CONDA sy-vline
WA_PA0143_STR-INSCT sy-vline
WA_PA0143_STR-INSPR sy-vline
WA_PA0143_STR-DVAMT sy-vline
WA_PA0143_STR-DIVYR sy-vline
WA_PA0143_STR-DIVMN sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.