ABAP Select data from SAP table P_FSTMTACDOC_OI into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP P_FSTMTACDOC_OI table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to P_FSTMTACDOC_OI. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the P_FSTMTACDOC_OI table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_P_FSTMTACDOC_OI TYPE STANDARD TABLE OF P_FSTMTACDOC_OI,
      WA_P_FSTMTACDOC_OI TYPE P_FSTMTACDOC_OI,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <P_FSTMTACDOC_OI> TYPE P_FSTMTACDOC_OI.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_P_FSTMTACDOC_OI.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM P_FSTMTACDOC_OI
  INTO TABLE IT_P_FSTMTACDOC_OI.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM P_FSTMTACDOC_OI
*  INTO TABLE @DATA(IT_P_FSTMTACDOC_OI2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_P_FSTMTACDOC_OI INDEX 1 INTO DATA(WA_P_FSTMTACDOC_OI2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_P_FSTMTACDOC_OI ASSIGNING <P_FSTMTACDOC_OI>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<P_FSTMTACDOC_OI>-MANDT = 1.
<P_FSTMTACDOC_OI>-RLDNR = 1.
<P_FSTMTACDOC_OI>-RBUKRS = 1.
<P_FSTMTACDOC_OI>-RACCT = 1.
<P_FSTMTACDOC_OI>-SEGMENT = 1.
ENDLOOP.

LOOP AT IT_P_FSTMTACDOC_OI INTO WA_P_FSTMTACDOC_OI.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_P_FSTMTACDOC_OI-PRCTR, sy-vline,
WA_P_FSTMTACDOC_OI-NETDUEDATE, sy-vline,
WA_P_FSTMTACDOC_OI-HSL, sy-vline,
WA_P_FSTMTACDOC_OI-KSL, sy-vline,
WA_P_FSTMTACDOC_OI-OSL, sy-vline,
WA_P_FSTMTACDOC_OI-VSL, sy-vline.
ENDLOOP. *Add any further fields from structure WA_P_FSTMTACDOC_OI you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_P_FSTMTACDOC_OI TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_P_FSTMTACDOC_OI INTO WA_P_FSTMTACDOC_OI. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field RLDNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_P_FSTMTACDOC_OI-RLDNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_P_FSTMTACDOC_OI-RLDNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RACCT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_P_FSTMTACDOC_OI-RACCT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_P_FSTMTACDOC_OI-RACCT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SEGMENT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_P_FSTMTACDOC_OI-SEGMENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_P_FSTMTACDOC_OI-SEGMENT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PRCTR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_P_FSTMTACDOC_OI-PRCTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_P_FSTMTACDOC_OI-PRCTR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_P_FSTMTACDOC_OI_STR,
MANDT TYPE STRING,
RLDNR TYPE STRING,
RBUKRS TYPE STRING,
RACCT TYPE STRING,
SEGMENT TYPE STRING,
PRCTR TYPE STRING,
NETDUEDATE TYPE STRING,
HSL TYPE STRING,
KSL TYPE STRING,
OSL TYPE STRING,
VSL TYPE STRING,
BSL TYPE STRING,
CSL TYPE STRING,
DSL TYPE STRING,
ESL TYPE STRING,
FSL TYPE STRING,
GSL TYPE STRING,
HBKID TYPE STRING,
HKTID TYPE STRING,
FUNCAREA TYPE STRING,END OF T_EKKO_STR. DATA: WA_P_FSTMTACDOC_OI_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_P_FSTMTACDOC_OI_STR-MANDT sy-vline
WA_P_FSTMTACDOC_OI_STR-RLDNR sy-vline
WA_P_FSTMTACDOC_OI_STR-RBUKRS sy-vline
WA_P_FSTMTACDOC_OI_STR-RACCT sy-vline
WA_P_FSTMTACDOC_OI_STR-SEGMENT sy-vline
WA_P_FSTMTACDOC_OI_STR-PRCTR sy-vline
WA_P_FSTMTACDOC_OI_STR-NETDUEDATE sy-vline
WA_P_FSTMTACDOC_OI_STR-HSL sy-vline
WA_P_FSTMTACDOC_OI_STR-KSL sy-vline
WA_P_FSTMTACDOC_OI_STR-OSL sy-vline
WA_P_FSTMTACDOC_OI_STR-VSL sy-vline
WA_P_FSTMTACDOC_OI_STR-BSL sy-vline
WA_P_FSTMTACDOC_OI_STR-CSL sy-vline
WA_P_FSTMTACDOC_OI_STR-DSL sy-vline
WA_P_FSTMTACDOC_OI_STR-ESL sy-vline
WA_P_FSTMTACDOC_OI_STR-FSL sy-vline
WA_P_FSTMTACDOC_OI_STR-GSL sy-vline
WA_P_FSTMTACDOC_OI_STR-HBKID sy-vline
WA_P_FSTMTACDOC_OI_STR-HKTID sy-vline
WA_P_FSTMTACDOC_OI_STR-FUNCAREA sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.