ABAP Select data from SAP table P6200 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP P6200 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to P6200. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the P6200 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_P6200 TYPE STANDARD TABLE OF P6200,
      WA_P6200 TYPE P6200,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <P6200> TYPE P6200.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_P6200.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM P6200
  INTO TABLE IT_P6200.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM P6200
*  INTO TABLE @DATA(IT_P62002).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_P6200 INDEX 1 INTO DATA(WA_P62002).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_P6200 ASSIGNING <P6200>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<P6200>-MANDT = 1.
<P6200>-PLVAR = 1.
<P6200>-OTYPE = 1.
<P6200>-OBJID = 1.
<P6200>-INFTY = 1.
ENDLOOP.

LOOP AT IT_P6200 INTO WA_P6200.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_P6200-SUBTY, sy-vline,
WA_P6200-ISTAT, sy-vline,
WA_P6200-PRIOX, sy-vline,
WA_P6200-BEGDA, sy-vline,
WA_P6200-ENDDA, sy-vline,
WA_P6200-VARYF, sy-vline.
ENDLOOP. *Add any further fields from structure WA_P6200 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_P6200 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_P6200 INTO WA_P6200. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_P6200_STR,
MANDT TYPE STRING,
PLVAR TYPE STRING,
OTYPE TYPE STRING,
OBJID TYPE STRING,
INFTY TYPE STRING,
SUBTY TYPE STRING,
ISTAT TYPE STRING,
PRIOX TYPE STRING,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
VARYF TYPE STRING,
SEQNR TYPE STRING,
AEDTM TYPE STRING,
UNAME TYPE STRING,
REASN TYPE STRING,
HISTO TYPE STRING,
ITXNR TYPE STRING,
REF_INFTY TYPE STRING,
REF_SUBTY TYPE STRING,
REF_BEGDA TYPE STRING,
REF_ENDDA TYPE STRING,
REF_VARYF TYPE STRING,
REF_SEQNR TYPE STRING,
PLAN_OPERATION TYPE STRING,
PLAN_GDATE TYPE STRING,END OF T_EKKO_STR. DATA: WA_P6200_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_P6200_STR-MANDT sy-vline
WA_P6200_STR-PLVAR sy-vline
WA_P6200_STR-OTYPE sy-vline
WA_P6200_STR-OBJID sy-vline
WA_P6200_STR-INFTY sy-vline
WA_P6200_STR-SUBTY sy-vline
WA_P6200_STR-ISTAT sy-vline
WA_P6200_STR-PRIOX sy-vline
WA_P6200_STR-BEGDA sy-vline
WA_P6200_STR-ENDDA sy-vline
WA_P6200_STR-VARYF sy-vline
WA_P6200_STR-SEQNR sy-vline
WA_P6200_STR-AEDTM sy-vline
WA_P6200_STR-UNAME sy-vline
WA_P6200_STR-REASN sy-vline
WA_P6200_STR-HISTO sy-vline
WA_P6200_STR-ITXNR sy-vline
WA_P6200_STR-REF_INFTY sy-vline
WA_P6200_STR-REF_SUBTY sy-vline
WA_P6200_STR-REF_BEGDA sy-vline
WA_P6200_STR-REF_ENDDA sy-vline
WA_P6200_STR-REF_VARYF sy-vline
WA_P6200_STR-REF_SEQNR sy-vline
WA_P6200_STR-PLAN_OPERATION sy-vline
WA_P6200_STR-PLAN_GDATE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.