ABAP Select data from SAP table P34_1721A2_REF into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP P34_1721A2_REF table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to P34_1721A2_REF. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the P34_1721A2_REF table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_P34_1721A2_REF TYPE STANDARD TABLE OF P34_1721A2_REF,
      WA_P34_1721A2_REF TYPE P34_1721A2_REF,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <P34_1721A2_REF> TYPE P34_1721A2_REF.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_P34_1721A2_REF.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM P34_1721A2_REF
  INTO TABLE IT_P34_1721A2_REF.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM P34_1721A2_REF
*  INTO TABLE @DATA(IT_P34_1721A2_REF2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_P34_1721A2_REF INDEX 1 INTO DATA(WA_P34_1721A2_REF2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_P34_1721A2_REF ASSIGNING <P34_1721A2_REF>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<P34_1721A2_REF>-EMP_TAXID = 1.
<P34_1721A2_REF>-EMP_NIP_NRP = 1.
<P34_1721A2_REF>-EMP_NAME = 1.
<P34_1721A2_REF>-EMP_RANK = 1.
<P34_1721A2_REF>-EMP_GROUP = 1.
ENDLOOP.

LOOP AT IT_P34_1721A2_REF INTO WA_P34_1721A2_REF.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_P34_1721A2_REF-EMP_ADDRESS, sy-vline,
WA_P34_1721A2_REF-GENDER, sy-vline,
WA_P34_1721A2_REF-EMP_NIK, sy-vline,
WA_P34_1721A2_REF-MARITAL_STATUS, sy-vline,
WA_P34_1721A2_REF-DEPENDENTS, sy-vline,
WA_P34_1721A2_REF-EMP_POSITION, sy-vline.
ENDLOOP. *Add any further fields from structure WA_P34_1721A2_REF you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_P34_1721A2_REF TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_P34_1721A2_REF INTO WA_P34_1721A2_REF. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_P34_1721A2_REF_STR,
EMP_TAXID TYPE STRING,
EMP_NIP_NRP TYPE STRING,
EMP_NAME TYPE STRING,
EMP_RANK TYPE STRING,
EMP_GROUP TYPE STRING,
EMP_ADDRESS TYPE STRING,
GENDER TYPE STRING,
EMP_NIK TYPE STRING,
MARITAL_STATUS TYPE STRING,
DEPENDENTS TYPE STRING,
EMP_POSITION TYPE STRING,END OF T_EKKO_STR. DATA: WA_P34_1721A2_REF_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_P34_1721A2_REF_STR-EMP_TAXID sy-vline
WA_P34_1721A2_REF_STR-EMP_NIP_NRP sy-vline
WA_P34_1721A2_REF_STR-EMP_NAME sy-vline
WA_P34_1721A2_REF_STR-EMP_RANK sy-vline
WA_P34_1721A2_REF_STR-EMP_GROUP sy-vline
WA_P34_1721A2_REF_STR-EMP_ADDRESS sy-vline
WA_P34_1721A2_REF_STR-GENDER sy-vline
WA_P34_1721A2_REF_STR-EMP_NIK sy-vline
WA_P34_1721A2_REF_STR-MARITAL_STATUS sy-vline
WA_P34_1721A2_REF_STR-DEPENDENTS sy-vline
WA_P34_1721A2_REF_STR-EMP_POSITION sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.