ABAP Select data from SAP table P3329 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP P3329 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to P3329. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the P3329 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_P3329 TYPE STANDARD TABLE OF P3329,
      WA_P3329 TYPE P3329,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <P3329> TYPE P3329.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_P3329.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM P3329
  INTO TABLE IT_P3329.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM P3329
*  INTO TABLE @DATA(IT_P33292).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_P3329 INDEX 1 INTO DATA(WA_P33292).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_P3329 ASSIGNING <P3329>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<P3329>-PERNR = 1.
<P3329>-INFTY = 1.
<P3329>-SUBTY = 1.
<P3329>-OBJPS = 1.
<P3329>-SPRPS = 1.
ENDLOOP.

LOOP AT IT_P3329 INTO WA_P3329.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_P3329-ENDDA, sy-vline,
WA_P3329-BEGDA, sy-vline,
WA_P3329-SEQNR, sy-vline,
WA_P3329-AEDTM, sy-vline,
WA_P3329-UNAME, sy-vline,
WA_P3329-HISTO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_P3329 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_P3329 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_P3329 INTO WA_P3329. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_P3329_STR,
PERNR TYPE STRING,
INFTY TYPE STRING,
SUBTY TYPE STRING,
OBJPS TYPE STRING,
SPRPS TYPE STRING,
ENDDA TYPE STRING,
BEGDA TYPE STRING,
SEQNR TYPE STRING,
AEDTM TYPE STRING,
UNAME TYPE STRING,
HISTO TYPE STRING,
ITXEX TYPE STRING,
REFEX TYPE STRING,
ORDEX TYPE STRING,
ITBLD TYPE STRING,
PREAS TYPE STRING,
FLAG1 TYPE STRING,
FLAG2 TYPE STRING,
FLAG3 TYPE STRING,
FLAG4 TYPE STRING,
RESE1 TYPE STRING,
RESE2 TYPE STRING,
GRPVL TYPE STRING,
ESTDT TYPE STRING,
PUSTY TYPE STRING,
PUSAC TYPE STRING,
LGART TYPE STRING,
DPOIT TYPE STRING,
REAMT TYPE STRING,
PUNRS TYPE STRING,
AUTHY TYPE STRING,
DCSTA TYPE STRING,
LSREA TYPE STRING,
LSDTE TYPE STRING,
VCATE TYPE STRING,
VIOID TYPE STRING,
SDOCU TYPE STRING,
SAUTH TYPE STRING,
SANCT TYPE STRING,
VCONT TYPE STRING,
PERCH TYPE STRING,END OF T_EKKO_STR. DATA: WA_P3329_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_P3329_STR-PERNR sy-vline
WA_P3329_STR-INFTY sy-vline
WA_P3329_STR-SUBTY sy-vline
WA_P3329_STR-OBJPS sy-vline
WA_P3329_STR-SPRPS sy-vline
WA_P3329_STR-ENDDA sy-vline
WA_P3329_STR-BEGDA sy-vline
WA_P3329_STR-SEQNR sy-vline
WA_P3329_STR-AEDTM sy-vline
WA_P3329_STR-UNAME sy-vline
WA_P3329_STR-HISTO sy-vline
WA_P3329_STR-ITXEX sy-vline
WA_P3329_STR-REFEX sy-vline
WA_P3329_STR-ORDEX sy-vline
WA_P3329_STR-ITBLD sy-vline
WA_P3329_STR-PREAS sy-vline
WA_P3329_STR-FLAG1 sy-vline
WA_P3329_STR-FLAG2 sy-vline
WA_P3329_STR-FLAG3 sy-vline
WA_P3329_STR-FLAG4 sy-vline
WA_P3329_STR-RESE1 sy-vline
WA_P3329_STR-RESE2 sy-vline
WA_P3329_STR-GRPVL sy-vline
WA_P3329_STR-ESTDT sy-vline
WA_P3329_STR-PUSTY sy-vline
WA_P3329_STR-PUSAC sy-vline
WA_P3329_STR-LGART sy-vline
WA_P3329_STR-DPOIT sy-vline
WA_P3329_STR-REAMT sy-vline
WA_P3329_STR-PUNRS sy-vline
WA_P3329_STR-AUTHY sy-vline
WA_P3329_STR-DCSTA sy-vline
WA_P3329_STR-LSREA sy-vline
WA_P3329_STR-LSDTE sy-vline
WA_P3329_STR-VCATE sy-vline
WA_P3329_STR-VIOID sy-vline
WA_P3329_STR-SDOCU sy-vline
WA_P3329_STR-SAUTH sy-vline
WA_P3329_STR-SANCT sy-vline
WA_P3329_STR-VCONT sy-vline
WA_P3329_STR-PERCH sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.