ABAP Select data from SAP table P3006 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP P3006 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to P3006. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the P3006 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_P3006 TYPE STANDARD TABLE OF P3006,
      WA_P3006 TYPE P3006,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <P3006> TYPE P3006.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_P3006.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM P3006
  INTO TABLE IT_P3006.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM P3006
*  INTO TABLE @DATA(IT_P30062).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_P3006 INDEX 1 INTO DATA(WA_P30062).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_P3006 ASSIGNING <P3006>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<P3006>-MANDT = 1.
<P3006>-PLVAR = 1.
<P3006>-OTYPE = 1.
<P3006>-OBJID = 1.
<P3006>-INFTY = 1.
ENDLOOP.

LOOP AT IT_P3006 INTO WA_P3006.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_P3006-SUBTY, sy-vline,
WA_P3006-ISTAT, sy-vline,
WA_P3006-PRIOX, sy-vline,
WA_P3006-BEGDA, sy-vline,
WA_P3006-ENDDA, sy-vline,
WA_P3006-VARYF, sy-vline.
ENDLOOP. *Add any further fields from structure WA_P3006 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_P3006 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_P3006 INTO WA_P3006. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_P3006_STR,
MANDT TYPE STRING,
PLVAR TYPE STRING,
OTYPE TYPE STRING,
OBJID TYPE STRING,
INFTY TYPE STRING,
SUBTY TYPE STRING,
ISTAT TYPE STRING,
PRIOX TYPE STRING,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
VARYF TYPE STRING,
SEQNR TYPE STRING,
AEDTM TYPE STRING,
UNAME TYPE STRING,
REASN TYPE STRING,
HISTO TYPE STRING,
ITXNR TYPE STRING,
CANUM TYPE STRING,
CAROL TYPE STRING,
FORK1 TYPE STRING,
FORK2 TYPE STRING,
FORK3 TYPE STRING,
FORKN TYPE STRING,
KAPID TYPE STRING,
PROZT TYPE STRING,
VERT1 TYPE STRING,
VERT2 TYPE STRING,
VERT3 TYPE STRING,
VERTN TYPE STRING,
ISTBED_KZ TYPE STRING,
VGWT1 TYPE STRING,
VGWT2 TYPE STRING,
VGWT3 TYPE STRING,
VGWTN TYPE STRING,
CAP_BACKFLUSH_SU TYPE STRING,
CAP_BACKFLUSH_PR TYPE STRING,
CAP_BACKFLUSH_TD TYPE STRING,END OF T_EKKO_STR. DATA: WA_P3006_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_P3006_STR-MANDT sy-vline
WA_P3006_STR-PLVAR sy-vline
WA_P3006_STR-OTYPE sy-vline
WA_P3006_STR-OBJID sy-vline
WA_P3006_STR-INFTY sy-vline
WA_P3006_STR-SUBTY sy-vline
WA_P3006_STR-ISTAT sy-vline
WA_P3006_STR-PRIOX sy-vline
WA_P3006_STR-BEGDA sy-vline
WA_P3006_STR-ENDDA sy-vline
WA_P3006_STR-VARYF sy-vline
WA_P3006_STR-SEQNR sy-vline
WA_P3006_STR-AEDTM sy-vline
WA_P3006_STR-UNAME sy-vline
WA_P3006_STR-REASN sy-vline
WA_P3006_STR-HISTO sy-vline
WA_P3006_STR-ITXNR sy-vline
WA_P3006_STR-CANUM sy-vline
WA_P3006_STR-CAROL sy-vline
WA_P3006_STR-FORK1 sy-vline
WA_P3006_STR-FORK2 sy-vline
WA_P3006_STR-FORK3 sy-vline
WA_P3006_STR-FORKN sy-vline
WA_P3006_STR-KAPID sy-vline
WA_P3006_STR-PROZT sy-vline
WA_P3006_STR-VERT1 sy-vline
WA_P3006_STR-VERT2 sy-vline
WA_P3006_STR-VERT3 sy-vline
WA_P3006_STR-VERTN sy-vline
WA_P3006_STR-ISTBED_KZ sy-vline
WA_P3006_STR-VGWT1 sy-vline
WA_P3006_STR-VGWT2 sy-vline
WA_P3006_STR-VGWT3 sy-vline
WA_P3006_STR-VGWTN sy-vline
WA_P3006_STR-CAP_BACKFLUSH_SU sy-vline
WA_P3006_STR-CAP_BACKFLUSH_PR sy-vline
WA_P3006_STR-CAP_BACKFLUSH_TD sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.